TL* THE CONTACT OWNS A 1996 FLEETWOOD BOUNDER. THE CONTACT STATED THAT THE VEHICLE WAS EQUIPPED WITH A P30 TRANSMISSION THAT WOULD CAUSE THE DRIVESHAFT TO SEIZE. THE CONTACT STATED THAT AFTER SHIFTING THE VEHICLE INTO PARK, THE VEHICLE WOULD ROLL AWAY. THE CONTACT WOULD HAVE TO CUT THE WHEELS IN ORDER TO PREVENT THE FAILURE. THE…
Read full complaint
TL* THE CONTACT OWNS A 1996 FLEETWOOD BOUNDER. THE CONTACT STATED THAT THE VEHICLE WAS EQUIPPED WITH A P30 TRANSMISSION THAT WOULD CAUSE THE DRIVESHAFT TO SEIZE. THE CONTACT STATED THAT AFTER SHIFTING THE VEHICLE INTO PARK, THE VEHICLE WOULD ROLL AWAY. THE CONTACT WOULD HAVE TO CUT THE WHEELS IN ORDER TO PREVENT THE FAILURE. THE VEHICLE WAS NOT INSPECTED BY A DEALER OR AN INDEPENDENT MECHANIC. THE MANUFACTURER WAS NOT CONTACTED. THE FAILURE MILEAGE WAS APPROXIMATELY 24,000. THE CURRENT MILEAGE WAS APPROXIMATELY 28,557. THE VIN WAS UNAVAILABLE. *TR
NHTSA ODI #10502648
Mileage unknown · Sep 24, 1998
Power Train
REAR AXLE BEARING LOCKS UP, CAUSING THE WHEELS TO LOCK .DEALER CHANGED BRAKES, AND REPLACED BEARINGS/WHEEL ASSEMBLY AND AXLE SEAL. *AK
NHTSA ODI #828189
Mileage unknown · Mar 7, 1996
Power Train
VEHICLE IS DIFFICULT TO STEER, FRONT AXLE IS WARPED. POWER STEERING GEAR BOX WAS WRONG. *AK
VEHICLE DESCRIPTION: MOTOR HOMES. THE DRIVER'S AND PASSENGER'S SIDE WINDOWS DO NOT MEET THE REQUIREMENTS OF FMVSS NO. 205, "GLAZING MATERIALS," FOR AN ACCEPTABLE LEVEL OF TINT.
Consequence & remedy
Consequence: THIS CONDITION COULD CAUSE THE DRIVER REDUCED VISIBILITY THROUGH THE SIDE WINDOWS WHEN BACKING UP, WHEN USING THE MIRRORS FOR LANE CHANGES, OR WHENEVER LOOKING THROUGH THE WINDOWS, INCREASING THE RISK OF A VEHICLE CRASH.
THE ELECTRIC WIRE USED TO POWER THE EXPANDABLE ROOM HYDRAULIC PUMP MOTOR WAS NOT EQUIPPED WITH A CIRCUIT BREAKER. OVERHEATING OF THE WIRE CAN OCCUR WITH INCORRECT EXPANDABLE ROOM OPERATION.
Consequence & remedy
Consequence: THIS CONDITION CAN CAUSE THE WIRE INSULATION TO MELT, CAUSING SMOKE AND POSSIBLE FIRE.
Remedy: DEALERS WILL INSTALL A CIRCUIT BREAKER TO THE EXPANDABLE ROOM SYSTEM PUMP MOTOR WIRE. FLEETWOOD WILL ALSO PROVIDE A VEHICLE LABEL TO IDENTIFY THE LOCATION OF THE CIRCUIT BREAKER, AND WILL PROVIDE OWNER'S MANUAL LITERATURE TO IDENTIFY THE CIRCUIT BREAKER LOCATION.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
0
No exact-year investigations in this snapshot.
1996 Fleetwood Bounder Problems, Complaints & Recalls | Skip That Year