Service Brakes, Air. Review the 1 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
0 crash reports0 fire reports0 injury reports
What owners actually said
1 reports
66,000 miles · Jan 20, 2009
Service Brakes, Air
2002 FLEETWOOD AMERICAN EAGLE 40' MOTOR COACH. AIR BRAKE HOLDING TANK. TWO (2) SUPPORT BRACKETS "NEVER" WELDED TO TANK WHICH IN TURN HOLDS THE TANK IN POSITION TO THE FRAME...IN 66,000 MILES OF BANGING AGAINST TANK, WORE TWO (2) HOLES IN TANK RELEASING AIR CAUSING LOSS OF BRAKES. NOTIFIED SPARTAN CHASSIS MANUFACTURE AND FLEETWO…
Read full complaint
2002 FLEETWOOD AMERICAN EAGLE 40' MOTOR COACH. AIR BRAKE HOLDING TANK. TWO (2) SUPPORT BRACKETS "NEVER" WELDED TO TANK WHICH IN TURN HOLDS THE TANK IN POSITION TO THE FRAME...IN 66,000 MILES OF BANGING AGAINST TANK, WORE TWO (2) HOLES IN TANK RELEASING AIR CAUSING LOSS OF BRAKES. NOTIFIED SPARTAN CHASSIS MANUFACTURE AND FLEETWOOD, BOTH SAY "IT'S OUT OF WARRANTY". THIS CONDITION UNDER THE RIGHT CIRCUMSTANCES CAN CAUSE COMPLETE LOSS OF BRAKING!! MANUFACTURE MUST BE NOTIFIED TO RECALL "ALL" TANKS TO INSPECT AND DETERMIN EMINENT DANGER OF. THANKS FOR YOUR IMMEDIATE CALL TO ACTION. *TR
FLEETWOOD RV IS RECALLING CERTAIN MODEL YEAR 2005 AND 2006 MOTORHOMES MANUFACTURED BETWEEN JULY 24, 2004 AND MARCH 11, 2005, EQUIPPED WITH NORCOLD MODEL 1200LR, 1200LRIM, AND 1201LRIM REFRIGERATORS WITH SERIAL NUMBERS BETWEEN 1273701 AND 1536607, NON-CONSECUTIVELY. A FATIGUE FAILURE IN THE SECTION OF THE COOLING UNIT WHICH CONTAINS THE REFRIGERANT COULD ALLOW THE LIQUID SOLUTION TO SLOWLY LEAK. IF A LEAK OCCURS AND THE REFRIGERATOR CONTINUES TO BE OPERATED AFTER SOLUTION CIRCULATION HAS CEASED THE HEAT SOURCE COULD GENERATE VERY HIGH TEMPERATURES. AT SUCH HIGH TEMPERATURES, THE COOLING UNIT COULD RUPTURE.
Consequence & remedy
Consequence: IF A LEAK OCCURS AND THE UNIT IS CONTINUES TO OPERATE, HYDROGEN GAS MAY BE EXPELLED AND CAN BE IGNITED, RESULTING IN A FIRE, POSSIBLY CAUSING SERIOUS INJURY OR DEATH.
Remedy: FLEETWOOD RV WILL NOTIFY OWNERS AND THE VEHICLE'S REFRIGERATOR WILL BE REPAIRED FREE OF CHARGE. THE SAFETY RECALL IS EXPECTED TO BEGIN DURING SEPTEMBER 2009. OWNERS MAY CONTACT FLEETWOOD RV AT 1-800-509-3418 OR NORCOLD'S RECALL CENTER AT 1-800-767-9101.
CERTAIN MOTOR HOMES AND TRAVEL TRAILERS EQUIPPED WITH A TWO-DOOR REFRIGERATOR, MANUFACTURED BY THE DOMETIC CORPORATION, MAY HAVE A DEFECT IN THE BOILER TUBE. PRESSURIZED COOLANT SOLUTION COULD BE RELEASED INTO AN AREA WHERE AN IGNITION SOURCE (GAS FLAME) IS PRESENT.
Consequence & remedy
Consequence: RELEASE OF COOLANT UNDER CERTAIN CONDITIONS COULD IGNITE AND RESULT IN A FIRE.
Remedy: FLEETWOOD WILL BE WORKING WITH DOMETIC IN ORDER TO REPAIR THESE REFRIGERATORS (PLEASE SEE 06E076). DOMETIC WILL REPAIR THESE REFRIGERATORS BY INSTALLING A SECONDARY BURN HOUSING, A THERMAL FUSE, AND A MELT FUSE FREE OF CHARGE. DOMETIC HAS RETAINED STERICYCLE INC. TO MANAGE THIS CAMPAIGN. STERICYCLE WILL ASSIST YOU IN LOCATING DEALERSHIPS OR SERVICE CENTERS AND WILL PROVIDE ASSISTANCE WITH SCHEDULING OF APPOINTMENTS. OWNERS MAY CONTACT DOMETIC/STERICYCLE AT 1-888-446-5157 OR FLEETWOOD AT 1-800-322-8216.
ON CERTAIN MOTORHOMES EQUIPPED WITH ARVINMERITOR WABCO PNEUMATIC ANITLOCK BRAKE SYSTEM (ABS) VALVE PACKAGES, THE ASSEMBLY BOLTS ON THESE VALVE PACKAGES WERE NOT TIGHTENED CORRECTLY.
Consequence & remedy
Consequence: BOLTS TORQUED BELOW SPECIFICATION WILL NOT RELIABLY PREVENT AIR LEAKAGE AT THE AFFECTED ABS VALVE PACKAGE INTERFACE JOINTS ONCE THE COMPONENT BEGINS NORMAL VEHICLE OPERATION. IF AIR LEAKS DEVELOP AT ANY OF THE ABS VALVE PACKAGE INTERFACE JOINTS, BRAKE SYSTEM PRESSURE REDUCTIONS COULD OCCUR DURING BRAKING OR NORMAL OPERATION WITH UNITS EQUIPPED WITH THE TRACTION CONTROL OPTION, POTENTIALLY EXTENDING STOPPING DISTANCES, POSSIBLY RESULTING IN A VEHICLE CRASH.
Remedy: DEALERS WILL TIGHTEN THE FASTENERS TO THE PROPER SPECIFICATION. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT ARVINMERITOR WABCO AT 1-859-746-5956 OR FLEETWOOD AT 1-800-629-8454.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
1
PE06005 · Inadvertent SLIDE-OUT Extension Movement
Opened Jan 20, 2006 · Closed May 2, 2006
Status: closed (inferred from source dates) · Equipment:recreational Vehicle/trailer
THIS INVESTIGATION WAS OPENED BASED ON ODI'S RECEIPT OF A CONGRESSIONAL LETTER ON BEHALF OF A CONSTITUENT.THE CONSTITUENT REPORTED INCIDENTS WHERE THE SLIDE OUT ROOM OF HIS MOTOR HOME WOULD INADVERTENTLY MOVE (EXTEND) DURING HIGHWAY USE.ODI WAS CONCERNED THAT A FULLY EXTENDED SLIDE OUT WOULD DEGRADE THE VEHICLE'S DYNAMIC HANDLING CHARACTERISTICS AND/OR POSSIBLY IMPACT AN OBJECT OR ANOTHER VEHICLE, RESULTING IN A CRASH.ODI CONTACTED FLEETWOOD AND DISCOVERED THAT SLIDE OUT ROOMS WERE INSTALLED IN MOTOR HOMES, TRAVEL TRAILERS AND FOLDING TRAILERS. AS PART OF THE INVESTIGATION ODI VISITED A RV SHOW AND THE FLEETWOOD PAXINOS PLANT TO EXAMINE SLIDE OUTS IN VARIOUS NEW MAKE AND MODEL VEHICLES AND GAIN AN UNDERSTANDING OF HOW THE SYSTEMS WORK.DURING THE INVESTIGATION ODI LEARNED THAT THERE ARE TWO METHODS USED TO EXTEND SLIDE OUT ROOMS.SOME MANUFACTURERS USE HYDRAULIC SYSTEMS AND OTHERS, SUCH AS FLEETWOOD, USE AN ELECTRIC MOTOR. (CONTINUED ON PAGE 2)