Limited mileage data: 10 of 21 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Structure. Review the 10 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Visibility. Review the 4 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 3 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

Wheels complaints

2 reports
Clear category filter
50,000 miles · Feb 17, 2021
Unknown Or OtherWheels

I PURCHASED MY 2016 BUICK CASCADA IN 2017, IN THE SUMMER OF 2018 I NOTICED THE PAINT CHIPPING OFF ALL 4 OF MY RIMS. THEN IN DECEMBER OF 2020 I NOTICED THE BACK WINDOW STARTED TO BECOME UNATTACHED FROM THE CONVERTIBLE TOP. THE VEHICLE IS NOW OUT OF WARRANTY AND THE DEALERSHIP TELLS ME I NEED TO REPLACE THE ENTIRE TOP, WHICH IS AB…

Read full complaint

I PURCHASED MY 2016 BUICK CASCADA IN 2017, IN THE SUMMER OF 2018 I NOTICED THE PAINT CHIPPING OFF ALL 4 OF MY RIMS. THEN IN DECEMBER OF 2020 I NOTICED THE BACK WINDOW STARTED TO BECOME UNATTACHED FROM THE CONVERTIBLE TOP. THE VEHICLE IS NOW OUT OF WARRANTY AND THE DEALERSHIP TELLS ME I NEED TO REPLACE THE ENTIRE TOP, WHICH IS ABSOLUTELY RIDICULOUS. I PAID $38,000 FOR A VEHICLE THAT IS FALLING APART. I DON'T UNDERSTAND WHY GENERAL MOTORS IT'S NOT HELD RESPONSIBLE FOR THIS?

NHTSA ODI #11396566

6,000 miles · Oct 13, 2017
EngineStructureWheels

TL* THE CONTACT OWNS A 2016 BUICK CASCADA. WHILE DRIVING APPROXIMATELY 1 MPH, THE VEHICLE DROVE OVER A CURB. WHEN THE VEHICLE WAS TAKEN TO AXELROD GMC BUICK (PARMA, OH, 216-661-5060) FOR AN OIL CHANGE, THE TECHNICIAN DIAGNOSED THAT THERE WAS A CRACK IN THE FRAME. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND SENT AN INVESTI…

Read full complaint

TL* THE CONTACT OWNS A 2016 BUICK CASCADA. WHILE DRIVING APPROXIMATELY 1 MPH, THE VEHICLE DROVE OVER A CURB. WHEN THE VEHICLE WAS TAKEN TO AXELROD GMC BUICK (PARMA, OH, 216-661-5060) FOR AN OIL CHANGE, THE TECHNICIAN DIAGNOSED THAT THERE WAS A CRACK IN THE FRAME. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE AND SENT AN INVESTIGATOR TO ASSESS THE DAMAGE. THE INVESTIGATOR WAS UNABLE TO DETERMINE THE CAUSE OF THE FAILURE. THE CONTACT WAS OFFERED A RENTAL VEHICLE WHILE THE DEALER KEPT THE VEHICLE FOR INVESTIGATION. WHEN THE CONTACT RETRIEVED THE VEHICLE, SHE NOTICED THAT ALL PARTS OF THE VEHICLE, INCLUDING THE STEERING WHEEL AND SEATS, VIBRATED. THE DEALER WAS UNABLE TO EXPLAIN THE CAUSE OF THE FAILURES AND DID NOT TEST DRIVE THE VEHICLE. THE MANUFACTURER WAS MADE AWARE OF THE FAILURES AND STATED THAT THE VEHICLE WAS PERFORMING AS EXPECTED. THE FAILURE RECURRED AND WAS NOT REPAIRED. THE FAILURE MILEAGE WAS APPROXIMATELY 6,000.

NHTSA ODI #11033212

Official recalls

1

16V844000 · Visibility:power Window Devices And Controls

Nov 21, 2016

General Motors LLC (GM) is recalling certain model year 2016 Buick Cascada vehicles manufactured December 1, 2015, to February 24, 2016. The affected vehicles may have had the original convertible roof control module (CRCM) replaced with an incorrect CRCM, that allows the windows to close automatically when the roof is closed and can allow the windows to be closed remotely from distances beyond 11 meters using the key fob. As such, these vehicles no longer meet the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 118, "Power-Operated Window Systems."

Consequence & remedy

Consequence: If the windows close automatically or can be closed remotely in ways that do not meet all the requirements of FMVSS 118, the unexpected closure can increase the risk of injury to the passengers.

Remedy: GM will notify owners, and dealers will replace the CRCM with correct module, free of charge. The recall began on December 1, 2016. Owners may contact Buick customer service at 1-800-521-7300. GM's number for this recall is 16126.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.