2014 Altec Crane

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Crane years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

No component reports in this snapshot.

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 0 of 0 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

What owners actually said

0 reports

No matching complaints in this snapshot.

Official recalls

2

18V791000 · Electrical SYSTEM:12V/24V/48V Battery:cables; Electrical System:wiring:fuses And Circuit Breakers

Nov 9, 2018

Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.

Consequence & remedy

Consequence: The insufficiently sized wire may overheat, increasing the risk of fire.

Remedy: Altec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.

Additional source detail variants (2)

Electrical System:wiring:fuses And Circuit Breakers

Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.

Consequence: The insufficiently sized wire may overheat, increasing the risk of fire.

Remedy: Altec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.

Electrical SYSTEM:12V/24V/48V Battery:cables

Altec Industries, Inc. (Altec) is recalling certain 2008-2018 Altec AC18, AC23, AC26, AC30 and AC38 Cranes and D2B, D3A, D4A/B, DL42B, DT65 and DT80 Digger Derrick vehicles. The wiring on the 12V circuit from the chassis battery to the Power Distribution Module (PDM) may be insufficiently sized.

Consequence: The insufficiently sized wire may overheat, increasing the risk of fire.

Remedy: Altec will notify owners, and dealers will replace the wiring to the PDM, with a larger wire and/or replace the circuit breaker, free of charge. The recall began January 9, 2019. Owners may contact Altec customer service at 1-877-462-5832. Altec's number for this recall is CSN 703.

18V708000 · Electrical System: Instrument Cluster/panel; Electrical System:software

Oct 9, 2018

Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.

Consequence & remedy

Consequence: Using an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.

Remedy: Altec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.

Additional source detail variants (2)

Electrical System:software

Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.

Consequence: Using an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.

Remedy: Altec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.

Electrical System: Instrument Cluster/panel

Altec Industries Inc. (Altec) is recalling certain 2014-2018 Altec AC40-152S Cranes. On the affected cranes, the electronic Load Moment and Area Protection (LMAP) screen may display incorrect load chart values.

Consequence: Using an incorrect chart value could lead to unit instability or loss of load control, increasing the risk of injury.

Remedy: Altec will notify owners, and dealers will update the LMAP software, as necessary, free of charge. The recall is expected to begin on December 4, 2018. Owners may contact Altec at 1-205-991-7733. Altec's number for this recall is CSN 696.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

0

No exact-year investigations in this snapshot.