Halcore Group, Inc. (Halcore) is recalling certain 2017 AEV Traumahawk Ambulances. These vehicles are equipped with a Vanner Incorporated-brand battery isolator module which may overheat and cause equipment failure.
Consequence & remedy
Consequence: If the battery isolator module overheats there is an increased risk of a fire. Additionally, if the equipment that is connected to the isolator does not work there is an increased risk of injury.
Remedy: Halcore will notify owners and dealers will replace the battery isolator module. The recall began April 9, 2018. Owners may contact Halcore customer service at 1-800-447-0343.
Halcore Group, Inc. (Halcore) is recalling certain model year 2014-2015 American Emergency Vehicles (AEV) Trauma Hawk emergency vehicles manufactured from December 1, 2014, through June 30, 2015. The affected vehicles are equipped with a back up camera system which may display images from the camera in reverse.
Consequence & remedy
Consequence: If an object or person are on the left side of the screen but are actually on the right side of the vehicle, or vice versa, there is an increased risk of a crash.
Remedy: Halcore will notify owners, and dealers will work with ASA Electronics to replace any camera that is not displaying the correct images. The recall began on September 11, 2015. Owners may contact AEV customer service at 1-800-374-9749 or ASA customer service at 1-877-384-4400. Halcore's number for this recall is 15E050.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗