This is a Thor Scope RV built on the Promaster 1500 platform. The incident involves the Onan gasoline powered generator, which is directly connected to the fuel tank. Next to the generator in the fuel line, there is a small white inline fuel filter connected by the fuel hose going over a nipple on the filter and reinforced by a …
Read full complaint
This is a Thor Scope RV built on the Promaster 1500 platform. The incident involves the Onan gasoline powered generator, which is directly connected to the fuel tank. Next to the generator in the fuel line, there is a small white inline fuel filter connected by the fuel hose going over a nipple on the filter and reinforced by a hose clamp. In my case, the hose clamp was not installed sufficiently over the nipple (far enough back on the fuel hose that it did not completely engage the nipple), and presumably from vibration associated with the generator operation and driving, the hose fully detached from the nipple and spilled fuel in an uncontrolled manner until I smelled/noticed it coming out from under the vehicle. There was certainly sufficient fuel to have started a major fire if it had reached an ignition source. Fortunately, I was able to get under the vehicle and push the parts back together once the problem was noticed. But, this would not have been possible if there were any ignition sources nearby. Fortunately, the vehicle was parked and off when the spill occurred. Had I not been able to stop the leak, it is my understanding that 3/4 of the tank would have drained since I've been told that the intake is located at the 1/4 full level of the tank to prevent the generator from running the vehicle completely out of fuel. Photos attached show the part after I pushed the hose back on and tried to reposition the hose clamp closer to the center of the filter. This was very difficult to do while laying on the ground under the vehicle, so I didn't get it on as far as I would have preferred until I was able to get the vehicle to a place where I could elevate it and get better access.
Thor Motor Coach (TMC) is recalling certain 2021-2024 Thor Rize and Scope motorhomes. The solar panel frame may fracture around the mounting bolts, allowing the panel to detach from the vehicle.
Consequence & remedy
Consequence: A detached solar panel can become a road hazard, increasing the risk of a crash.
Remedy: Dealers will replace the lower bracket, free of charge. Owner notification letters were mailed January 9, 2024. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000298.
Thor Motor Coach (TMC) is recalling certain 2021-2023 Sequence, 2021-2024 Rize, Scope, Tellaro, 2023-2024 Dazzle, and Twist motorhomes, equipped with certain Cummins Onan QG 2800i generator sets. The fuel hose between the inline fuel filter and the injection pump module (IPM) may have inadequate clamp force, possibly resulting in a gasoline leak.
Consequence & remedy
Consequence: A gas leak in the presence of an ignition source increases the risk of a fire.
Remedy: Dealers will inspect and replace the fuel hose and clamps, as necessary, free of charge. Owner notification letters were mailed May 22, 2023. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000294.
Thor Motor Coach (TMC) is recalling certain 2021-2023 Rize and Scope camper vans. The retractable awning may extend unintentionally during transit.
Consequence & remedy
Consequence: An awning extending unintentionally during transit may become a distraction or road hazard, increasing the risk of a crash.
Remedy: Dealers will install an additional ignition cutoff wire harness at the BT12 module, free of charge. Owner notification letters were mailed March 28, 2023. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000289.
Thor Motor Coach (TMC) is recalling certain 2022 Scope, Tellaro, Sanctuary, Delano, Sequence, Tranquility, Rize, Synergy, Quantum, Magnitude, Geneva, Compass, Chateau, Four Winds, and 2022-2023 Tiburon, and Gemini vehicles. The quick disconnect fittings in the LP gas system may be cracked, causing a gas leak.
Consequence & remedy
Consequence: A gas leak in the presence of an ignition source can increase the risk of a fire.
Remedy: Dealers will replace the quick disconnect fittings, free of charge. Owner notification letters were mailed June 27, 2022. Owners may contact TMC customer service at 1-877-855-2867.
Thor Motor Coach (TMC) is recalling certain 2022 Scope and Rize motorhomes. The LP gas line may be too short and improperly installed, creating an excessive bend in the line which could rupture and leak.
Consequence & remedy
Consequence: A gas leak increases the risk of a fire.
Remedy: Dealers will replace the LP gas line and reroute it as necessary, free of charge. Owner notification letters were mailed November 23, 2021. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000243.
Thor Motor Coach (TMC) is recalling certain 2022 Rize, Scope, Sequence, and Tellaro vehicles. The Flex-190 Solar Panel junction box may short.
Consequence & remedy
Consequence: An electrical short can cause the junction box to overheat, increasing the risk of a fire.
Remedy: Dealers will install a new solar panel and junction box, free of charge. Owner notification letters were mailed July 22, 2021. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000226.
Additional source detail variants (2)
Equipment:recreational Vehicle/trailer
Thor Motor Coach (TMC) is recalling certain 2022 Rize, Scope, Sequence, and Tellaro vehicles. The Flex-190 Solar Panel junction box may short.
Consequence: An electrical short can cause the junction box to overheat, increasing the risk of a fire.
Remedy: Dealers will install a new solar panel and junction box, free of charge. Owner notification letters were mailed July 22, 2021. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000226.
Electrical System:wiring
Thor Motor Coach (TMC) is recalling certain 2022 Rize, Scope, Sequence, and Tellaro vehicles. The Flex-190 Solar Panel junction box may short.
Consequence: An electrical short can cause the junction box to overheat, increasing the risk of a fire.
Remedy: Dealers will install a new solar panel and junction box, free of charge. Owner notification letters were mailed July 22, 2021. Owners may contact TMC customer service at 1-877-855-2867. TMC's number for this recall is RC000226.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗