GAS TANK LEAK ON 2000 SUZUKI INTRUDER 1500. MAY CAUSE INJURY OR DEATH IF LEAKS ON EXHAUST SYSTEM. *AK
2000 Suzuki Intruder
Owner reports · Recalls · Investigations
Limited comparison data
There is not enough comparable history to draw a useful model-year comparison.
About this comparison →How this year compares
Owner complaints by model year
Compare all Intruder years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 12 of 18 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Power Train. Review the 10 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Fuel System, Gasoline. Review the 3 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Service Brakes, Hydraulic. Review the 2 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
Fuel System, Gasoline complaints
3 reportsTHE FUEL TANK UNDER THE SEAT CRACKED AND LEAKED. THE CRACK IS ALWAYS LOCATED ON THE UPPER RIGHT MOUNT AREA. IT'S A SMALL HAIRLINE CRACK AT FIRST AND DIFFICULT TO SEE. THE PROBLEM IS WELL DOCUMENTED ON THE LC/C90 DELPHI FORUM. FUEL RUNS OUT OF THE TANK CAUSING A POTENTIAL FIRE PROBLEM. I USED JB WELD TO CORRECT THE PROBLEM. OTH…
Read full complaint
THE FUEL TANK UNDER THE SEAT CRACKED AND LEAKED. THE CRACK IS ALWAYS LOCATED ON THE UPPER RIGHT MOUNT AREA. IT'S A SMALL HAIRLINE CRACK AT FIRST AND DIFFICULT TO SEE. THE PROBLEM IS WELL DOCUMENTED ON THE LC/C90 DELPHI FORUM. FUEL RUNS OUT OF THE TANK CAUSING A POTENTIAL FIRE PROBLEM. I USED JB WELD TO CORRECT THE PROBLEM. OTHER HAD HAVE HAD A NEW TANK INSTALLED WHICH CAN CRACK TOO. THIS IS A VERY COMMON PROBLEM WITH INTRUDER 1500 LC'S.*JB
MY SUZUKI 1500 INTRUDER MOTORCYCLE'S EMISSIONS SYSTEM FAILED. I NOTICED SMELL OF GASOLINE ABOUT THE VEHICLE. UPON INSPECTION I FOUND A BAD WELD IN THE SEAM ON THE GAS TANK AT THE FRONT RIGHT MOUNTING TAB. FOR SOME REASON THE TANK SEEMS TO BE UNDER STRESS AT THAT POINT, THAT COMBINED WITH A DEFECTIVE SEAM WELD AT THAT LOCATION C…
Read full complaint
MY SUZUKI 1500 INTRUDER MOTORCYCLE'S EMISSIONS SYSTEM FAILED. I NOTICED SMELL OF GASOLINE ABOUT THE VEHICLE. UPON INSPECTION I FOUND A BAD WELD IN THE SEAM ON THE GAS TANK AT THE FRONT RIGHT MOUNTING TAB. FOR SOME REASON THE TANK SEEMS TO BE UNDER STRESS AT THAT POINT, THAT COMBINED WITH A DEFECTIVE SEAM WELD AT THAT LOCATION CAUSED A LEAK A THAT POINT. I HAVE TEMPORARILY REPAIRED THE TANK BY REMOVING THE BOLT FROM THAT AREA RELIEVING THE STRESS AND COVERED THE LEAKING AREA WITH EPOXY TO STOP THE GAS LEAK. I HAVE SEVERAL OTHER FRIENDS THAT HAVE EXPERIENCED THE EXACT SAME PROBLEM AND CAN PUT YOU IN CONTACT WITH THEM IF YOU LIKE. *JB