2000 PONTIAC SUNFIRE EXPERIENCING FUEL PUMP MALFUNCTIONS AT VEHICLE AGE OF 3.5 YRS. CAR HAS BEEN TAKEN TO MULIPLE MECHANICS, ALL OF WHOM SUGGEST PUMP MALFUNCTION AND RECCOMMEND REPLACEMENT OF FUEL PUMP, FILTER AND RELAY VALVE. MANUFACTURER WARRANTY OF 3 YEARS OR 36,000 MILES HAS EXPIRED FOR THIS VEHICLE. CAR INITIALLY TAKEN IN…
Read full complaint
2000 PONTIAC SUNFIRE EXPERIENCING FUEL PUMP MALFUNCTIONS AT VEHICLE AGE OF 3.5 YRS. CAR HAS BEEN TAKEN TO MULIPLE MECHANICS, ALL OF WHOM SUGGEST PUMP MALFUNCTION AND RECCOMMEND REPLACEMENT OF FUEL PUMP, FILTER AND RELAY VALVE. MANUFACTURER WARRANTY OF 3 YEARS OR 36,000 MILES HAS EXPIRED FOR THIS VEHICLE. CAR INITIALLY TAKEN INTO PONTIAC DEALERSHIP FOR SERVICING A PROBLEM WITH IGNITION. ENGINE WOULD TURN BUT NOT FIRE RESULTING IN NO IGNITION. CAR OWNER PAID FOR REPLACEMENT OF FUEL PUMP, FILTER AND RELAY VALVE.
NHTSA ODI #10039590
Mileage unknown · Jul 31, 2003
Electrical SystemFuel System, Other
I HAVE HAD MY VEHICLE IN FOR BRAKE REPAIR SEVERAL TIMES IN THE PAST 3 1/2 YRS. AT LEAST 5-7 TIMES. MY CAR IS NOW EXPERIENCING SEVERAL ELECTRICAL PROBLEMS WITH A PLUG UNDER THE HARNESS AND WITH THE COMPUTER SYSTEM AND WIRING. MY CAR WILL NOT START FOR SEVERAL DAYS AND THEN IT WILL START, ONLY TO BREAKDOWN AGAIN WHEN IT HEATS UP.…
Read full complaint
I HAVE HAD MY VEHICLE IN FOR BRAKE REPAIR SEVERAL TIMES IN THE PAST 3 1/2 YRS. AT LEAST 5-7 TIMES. MY CAR IS NOW EXPERIENCING SEVERAL ELECTRICAL PROBLEMS WITH A PLUG UNDER THE HARNESS AND WITH THE COMPUTER SYSTEM AND WIRING. MY CAR WILL NOT START FOR SEVERAL DAYS AND THEN IT WILL START, ONLY TO BREAKDOWN AGAIN WHEN IT HEATS UP. IT HAS ALSO CUT OFF WHILE I WAS DRIVING 70 MPH ON THE EXPRESSWAY.IT HAS BEEN TOWED 3 TIMES IN THREE WEEKS FOR REPAIR DUE TO THESE PROBLEMS. I'VE SPENT SEVERAL HUNDRED DOLLARS TRYING TO FIX THESE PROBLEMS AND NOTHING SEEMS TO WORK. THE PLUG UNDER THE HARNESS WAS MELTING THROUGH MY BACK FLOORBOARD, MELTING MY CARPET WITH THE POTENTIAL TO CATCH ON FIRE. I WAS INFORMED BY THE SERVICE MEN THAT I'M EXPERIENCING COMPUTER AND WIRING PROBLEMS. THEY ADVISED ME TO CONTACT MY INSURANCE COMPANY REGARDING TOTALING MY CAR OUT BECAUSE IT HAS GREAT POTENTIAL TO CATCH ON FIRE. I CONTACTED GM'S CUSTOMER ASSISTANCE CENTER REGARDING ALL OF THE PROBLEMS I'M HAVING AND THEY ARE NOT WILLING TO HELP DUE TO MY CAR BEING 3 1/2 YRS. OLD. THERE HAVE BEEN SEVERAL OTHER SMALL ISSUES WITH THIS VEHICLE, BUT THIS CAR IS VERY DANGEROUS AND I CANNOT AFFORD TO KEEP WASTING MONEY ON REPAIRS. I THINK A CAR SHOULD LAST MORE THAN 3 1/2 YRS! JULY 26TH 2003 WAS THE LAST TOW DATE AND IT'S STILL IN THE SHOP. CAN YOU HELP? *PH
ON CERTAIN PASSENGER VEHICLES. IF THE ENGINE FAILS TO START AND THE DRIVER HOLDS THE KEY IN THE "START" POSITION FOR AN EXTENDED PERIOD, HIGH CURRENT FLOWS THROUGH THE IGNITION SWITCH, AND SOMETIMES PRODUCES ENOUGH HEAT TO MELT INTERNAL SWITCH PARTS.
Consequence & remedy
Consequence: IF THE SWITCH IS DAMAGED, A FIRE COULD OCCUR IN THE STEERING COLUMN, EVEN WITH THE ENGINE OFF AND THE KEY REMOVED. THE FIRE COULD SPREAD TO THE INTERIOR OF THE CAR, WHICH COULD INJURE OCCUPANTS OR CAUSE DAMAGE TO ADJOINING STRUCTURES.
Remedy: DEALERS WILL INSTALL A RELAY KIT IN THESE VEHICLES TO PREVENT HIGH CURRENT FROM FLOWING THROUGH THE IGNITION SWITCH, AND CHECK THAT YOUR CAR WILL START WITH A PROPERLY CHARGED BATTERY AND, IF NECESSARY, REPLACE THE IGNITION SWITCH. OWNER NOTIFICATION WILL BEGIN ON MARCH 1, 2004. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT CHEVROLET AT 1-800-630-2438, PONTIAC AT 1-800-620-7668, BUICK AT 1-866-608-8080, OR OLDSMOBILE AT 1-800-630-6537. CUSTOMERS CAN ALSO CHECK THEIR VEHICLE ONLINE BY GOING TO WWW.MYGMLINK.COM AND ENTERING THE VEHICLE'S IDENTIFICATION NUMBER.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
3
EA02028 · Erratic Fuel Gauge
Opened Sep 30, 2002 · Closed Dec 30, 2003
Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Other:storage:fuel Gauge System
ODI OPENED EA 02-028 TO REVIEW COMPLAINTS OF CONSUMERS REPORTING THAT THEIR FUEL GAUGE WAS INCORRECTLY DISPLAYING THE AMOUNT OF FUEL IN THE GAS TANK.THE FUEL GAUGE RECEIVES AN ELECTRICAL SIGNAL FROM A FUEL TANK SENDING SENSOR CIRCUIT CARD.A FLOAT ARM IN THE TANK MOVES ELECTRICAL CONTACTS THAT RUB AGAINST THE CARD AS THE LEVEL OF FUEL RISES AND FALLS.DISRUPTION OF THE ELECTRICAL SIGNAL (SUCH AS CAUSED BY CORROSION OF THE CIRCUIT CARD) WILL CAUSE INCORRECT READINGS TO REGISTER ON THE FUEL GAUGE.GM REPORTED IN THEIR RESPONSE TO ODI DATED JANUARY 13, 2003 THAT THE PRIMARY CAUSE OF ERRATIC FUEL GAUGE OPERATION IS EXCESS ELEMENTAL SULFUR IN FUEL.GM REPORTED THAT ABNORMAL LEVELS OF SULFUR SPORADICALLY OCCURRED IN CERTAIN PARTS OF CANADA AND THE U.S. RESULTING IN REPORTS OF FUEL GAUGE MALFUNCTION.GM MODIFIED THE SENDING SENSOR FOR VEHICLES BUILT AFTER OCTOBER 2000.IT MADE A SECOND SENSOR MODIFICATION FOR VEHICLES BUILT AFTER JANUARY 2003.GM ALSO ISSUED A CUSTOMER SATISFACTION CAMPAIGN (GM NUMBER 00101) IN DECEMBER 2000 FOR U.S. CUSTOMERS IN THE STATE OF MAINE AND ISSUED SEVERAL SERVICE BULLETINS INFORMING DEALERS OF THE AVAILABILITY OF SENSORS WITH IMPROVED CORROSION RESISTANCE.THE COMPLAINT TREND INDICATES THAT COMPLAINTS PEAKED IN LATE 2000 TO EARLY 2001.WARRANTY CLAIMS DECLINED SINCE PEAKING IN APRIL 2002.BASED ON THE NUMBER OF COMPLAINTS AND THE INDICATION OF A DECLINING TREND, FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Additional source detail variants (2)
Fuel System, Gasoline
ODI OPENED EA 02-028 TO REVIEW COMPLAINTS OF CONSUMERS REPORTING THAT THEIR FUEL GAUGE WAS INCORRECTLY DISPLAYING THE AMOUNT OF FUEL IN THE GAS TANK.THE FUEL GAUGE RECEIVES AN ELECTRICAL SIGNAL FROM A FUEL TANK SENDING SENSOR CIRCUIT CARD.A FLOAT ARM IN THE TANK MOVES ELECTRICAL CONTACTS THAT RUB AGAINST THE CARD AS THE LEVEL OF FUEL RISES AND FALLS.DISRUPTION OF THE ELECTRICAL SIGNAL (SUCH AS CAUSED BY CORROSION OF THE CIRCUIT CARD) WILL CAUSE INCORRECT READINGS TO REGISTER ON THE FUEL GAUGE.GM REPORTED IN THEIR RESPONSE TO ODI DATED JANUARY 13, 2003 THAT THE PRIMARY CAUSE OF ERRATIC FUEL GAUGE OPERATION IS EXCESS ELEMENTAL SULFUR IN FUEL.GM REPORTED THAT ABNORMAL LEVELS OF SULFUR SPORADICALLY OCCURRED IN CERTAIN PARTS OF CANADA AND THE U.S. RESULTING IN REPORTS OF FUEL GAUGE MALFUNCTION.GM MODIFIED THE SENDING SENSOR FOR VEHICLES BUILT AFTER OCTOBER 2000.IT MADE A SECOND SENSOR MODIFICATION FOR VEHICLES BUILT AFTER JANUARY 2003.GM ALSO ISSUED A CUSTOMER SATISFACTION CAMPAIGN (GM NUMBER 00101) IN DECEMBER 2000 FOR U.S. CUSTOMERS IN THE STATE OF MAINE AND ISSUED SEVERAL SERVICE BULLETINS INFORMING DEALERS OF THE AVAILABILITY OF SENSORS WITH IMPROVED CORROSION RESISTANCE.THE COMPLAINT TREND INDICATES THAT COMPLAINTS PEAKED IN LATE 2000 TO EARLY 2001.WARRANTY CLAIMS DECLINED SINCE PEAKING IN APRIL 2002.BASED ON THE NUMBER OF COMPLAINTS AND THE INDICATION OF A DECLINING TREND, FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
Fuel System, Other:storage:fuel Gauge System
ODI OPENED EA 02-028 TO REVIEW COMPLAINTS OF CONSUMERS REPORTING THAT THEIR FUEL GAUGE WAS INCORRECTLY DISPLAYING THE AMOUNT OF FUEL IN THE GAS TANK.THE FUEL GAUGE RECEIVES AN ELECTRICAL SIGNAL FROM A FUEL TANK SENDING SENSOR CIRCUIT CARD.A FLOAT ARM IN THE TANK MOVES ELECTRICAL CONTACTS THAT RUB AGAINST THE CARD AS THE LEVEL OF FUEL RISES AND FALLS.DISRUPTION OF THE ELECTRICAL SIGNAL (SUCH AS CAUSED BY CORROSION OF THE CIRCUIT CARD) WILL CAUSE INCORRECT READINGS TO REGISTER ON THE FUEL GAUGE.GM REPORTED IN THEIR RESPONSE TO ODI DATED JANUARY 13, 2003 THAT THE PRIMARY CAUSE OF ERRATIC FUEL GAUGE OPERATION IS EXCESS ELEMENTAL SULFUR IN FUEL.GM REPORTED THAT ABNORMAL LEVELS OF SULFUR SPORADICALLY OCCURRED IN CERTAIN PARTS OF CANADA AND THE U.S. RESULTING IN REPORTS OF FUEL GAUGE MALFUNCTION.GM MODIFIED THE SENDING SENSOR FOR VEHICLES BUILT AFTER OCTOBER 2000.IT MADE A SECOND SENSOR MODIFICATION FOR VEHICLES BUILT AFTER JANUARY 2003.GM ALSO ISSUED A CUSTOMER SATISFACTION CAMPAIGN (GM NUMBER 00101) IN DECEMBER 2000 FOR U.S. CUSTOMERS IN THE STATE OF MAINE AND ISSUED SEVERAL SERVICE BULLETINS INFORMING DEALERS OF THE AVAILABILITY OF SENSORS WITH IMPROVED CORROSION RESISTANCE.THE COMPLAINT TREND INDICATES THAT COMPLAINTS PEAKED IN LATE 2000 TO EARLY 2001.WARRANTY CLAIMS DECLINED SINCE PEAKING IN APRIL 2002.BASED ON THE NUMBER OF COMPLAINTS AND THE INDICATION OF A DECLINING TREND, FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.
ODI OPENED PE02-066 TO EVALUATE THE SCOPE AND CONSEQUENCE OF ENGINE POWER-LOSS DUE TO FUEL STARVATION INDUCED BY IN-TANK MODULAR FUEL PUMP STRAINER RESTRICTION.THE SUBJECT PUMPS USE AN EXTERNAL ?SOCK? STRAINER TO FILTER FUEL FLOWING TO THE PUMP INLET.THIS FILTER CAN SOMETIMES BECOME CLOGGED, RESULTING IN A REDUCED FLOW OF FUEL TO THE ENGINE.GM HAS SUBSEQUENTLY MODIFIED THE STRAINERS TO REDUCE THIS RESTRICTION.ANALYSIS OF THE ODI COMPLAINT DATABASE SHOWS THAT DESPITE THESE RESTRICTIONS, THE SUBJECT VEHICLES STALL AT A RATE THAT IS COMPARABLE TO THOSE OF MANY PEER VEHICLES.ADDITIONALLY, NONE OF THE RELEVANT WARRANTY REPAIR RATES EXCEED 1% AT 36 MONTHS OF EXPOSURE.ONE RELATED CRASH INVOLVES A STALLED VEHICLE THAT WAS REAR-ENDED ON THE ROADWAY, WHILE THE REMAINDER INVOLVED MINOR COLLISIONS OR SCRAPES.THE SOLE INJURY CONSISTED OF BRUISING FROM A LOW SPEED FRONTAL CRASH. GIVEN THESE CIRCUMSTANCES, FURTHER EXPENDITURE OF AGENCY RESOURCES IS NOT JUSTIFIED IN THIS MATTER.THE PRELIMINARY EVALUATION IS THEREFORE CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY WILL TAKE FURTHER ACTION IN THE FUTURE IF WARRANTED.
Additional source detail variants (4)
Fuel System, Gasoline:delivery:fuel Pump
ODI OPENED PE02-066 TO EVALUATE THE SCOPE AND CONSEQUENCE OF ENGINE POWER-LOSS DUE TO FUEL STARVATION INDUCED BY IN-TANK MODULAR FUEL PUMP STRAINER RESTRICTION.THE SUBJECT PUMPS USE AN EXTERNAL ?SOCK? STRAINER TO FILTER FUEL FLOWING TO THE PUMP INLET.THIS FILTER CAN SOMETIMES BECOME CLOGGED, RESULTING IN A REDUCED FLOW OF FUEL TO THE ENGINE.GM HAS SUBSEQUENTLY MODIFIED THE STRAINERS TO REDUCE THIS RESTRICTION.ANALYSIS OF THE ODI COMPLAINT DATABASE SHOWS THAT DESPITE THESE RESTRICTIONS, THE SUBJECT VEHICLES STALL AT A RATE THAT IS COMPARABLE TO THOSE OF MANY PEER VEHICLES.ADDITIONALLY, NONE OF THE RELEVANT WARRANTY REPAIR RATES EXCEED 1% AT 36 MONTHS OF EXPOSURE.ONE RELATED CRASH INVOLVES A STALLED VEHICLE THAT WAS REAR-ENDED ON THE ROADWAY, WHILE THE REMAINDER INVOLVED MINOR COLLISIONS OR SCRAPES.THE SOLE INJURY CONSISTED OF BRUISING FROM A LOW SPEED FRONTAL CRASH. GIVEN THESE CIRCUMSTANCES, FURTHER EXPENDITURE OF AGENCY RESOURCES IS NOT JUSTIFIED IN THIS MATTER.THE PRELIMINARY EVALUATION IS THEREFORE CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY WILL TAKE FURTHER ACTION IN THE FUTURE IF WARRANTED.
Fuel System, Gasoline
ODI OPENED PE02-066 TO EVALUATE THE SCOPE AND CONSEQUENCE OF ENGINE POWER-LOSS DUE TO FUEL STARVATION INDUCED BY IN-TANK MODULAR FUEL PUMP STRAINER RESTRICTION.THE SUBJECT PUMPS USE AN EXTERNAL ?SOCK? STRAINER TO FILTER FUEL FLOWING TO THE PUMP INLET.THIS FILTER CAN SOMETIMES BECOME CLOGGED, RESULTING IN A REDUCED FLOW OF FUEL TO THE ENGINE.GM HAS SUBSEQUENTLY MODIFIED THE STRAINERS TO REDUCE THIS RESTRICTION.ANALYSIS OF THE ODI COMPLAINT DATABASE SHOWS THAT DESPITE THESE RESTRICTIONS, THE SUBJECT VEHICLES STALL AT A RATE THAT IS COMPARABLE TO THOSE OF MANY PEER VEHICLES.ADDITIONALLY, NONE OF THE RELEVANT WARRANTY REPAIR RATES EXCEED 1% AT 36 MONTHS OF EXPOSURE.ONE RELATED CRASH INVOLVES A STALLED VEHICLE THAT WAS REAR-ENDED ON THE ROADWAY, WHILE THE REMAINDER INVOLVED MINOR COLLISIONS OR SCRAPES.THE SOLE INJURY CONSISTED OF BRUISING FROM A LOW SPEED FRONTAL CRASH. GIVEN THESE CIRCUMSTANCES, FURTHER EXPENDITURE OF AGENCY RESOURCES IS NOT JUSTIFIED IN THIS MATTER.THE PRELIMINARY EVALUATION IS THEREFORE CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY WILL TAKE FURTHER ACTION IN THE FUTURE IF WARRANTED.
Fuel System, Other:delivery:fuel Pump
ODI OPENED PE02-066 TO EVALUATE THE SCOPE AND CONSEQUENCE OF ENGINE POWER-LOSS DUE TO FUEL STARVATION INDUCED BY IN-TANK MODULAR FUEL PUMP STRAINER RESTRICTION.THE SUBJECT PUMPS USE AN EXTERNAL ?SOCK? STRAINER TO FILTER FUEL FLOWING TO THE PUMP INLET.THIS FILTER CAN SOMETIMES BECOME CLOGGED, RESULTING IN A REDUCED FLOW OF FUEL TO THE ENGINE.GM HAS SUBSEQUENTLY MODIFIED THE STRAINERS TO REDUCE THIS RESTRICTION.ANALYSIS OF THE ODI COMPLAINT DATABASE SHOWS THAT DESPITE THESE RESTRICTIONS, THE SUBJECT VEHICLES STALL AT A RATE THAT IS COMPARABLE TO THOSE OF MANY PEER VEHICLES.ADDITIONALLY, NONE OF THE RELEVANT WARRANTY REPAIR RATES EXCEED 1% AT 36 MONTHS OF EXPOSURE.ONE RELATED CRASH INVOLVES A STALLED VEHICLE THAT WAS REAR-ENDED ON THE ROADWAY, WHILE THE REMAINDER INVOLVED MINOR COLLISIONS OR SCRAPES.THE SOLE INJURY CONSISTED OF BRUISING FROM A LOW SPEED FRONTAL CRASH. GIVEN THESE CIRCUMSTANCES, FURTHER EXPENDITURE OF AGENCY RESOURCES IS NOT JUSTIFIED IN THIS MATTER.THE PRELIMINARY EVALUATION IS THEREFORE CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY WILL TAKE FURTHER ACTION IN THE FUTURE IF WARRANTED.
Fuel System, Other
ODI OPENED PE02-066 TO EVALUATE THE SCOPE AND CONSEQUENCE OF ENGINE POWER-LOSS DUE TO FUEL STARVATION INDUCED BY IN-TANK MODULAR FUEL PUMP STRAINER RESTRICTION.THE SUBJECT PUMPS USE AN EXTERNAL ?SOCK? STRAINER TO FILTER FUEL FLOWING TO THE PUMP INLET.THIS FILTER CAN SOMETIMES BECOME CLOGGED, RESULTING IN A REDUCED FLOW OF FUEL TO THE ENGINE.GM HAS SUBSEQUENTLY MODIFIED THE STRAINERS TO REDUCE THIS RESTRICTION.ANALYSIS OF THE ODI COMPLAINT DATABASE SHOWS THAT DESPITE THESE RESTRICTIONS, THE SUBJECT VEHICLES STALL AT A RATE THAT IS COMPARABLE TO THOSE OF MANY PEER VEHICLES.ADDITIONALLY, NONE OF THE RELEVANT WARRANTY REPAIR RATES EXCEED 1% AT 36 MONTHS OF EXPOSURE.ONE RELATED CRASH INVOLVES A STALLED VEHICLE THAT WAS REAR-ENDED ON THE ROADWAY, WHILE THE REMAINDER INVOLVED MINOR COLLISIONS OR SCRAPES.THE SOLE INJURY CONSISTED OF BRUISING FROM A LOW SPEED FRONTAL CRASH. GIVEN THESE CIRCUMSTANCES, FURTHER EXPENDITURE OF AGENCY RESOURCES IS NOT JUSTIFIED IN THIS MATTER.THE PRELIMINARY EVALUATION IS THEREFORE CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT NO SAFETY-RELATED DEFECT EXISTS.THE AGENCY WILL TAKE FURTHER ACTION IN THE FUTURE IF WARRANTED.
SQ01002 · Erratic Fuel Gauge
Opened Jan 26, 2001 · Closed Sep 30, 2002
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages