← New search

2008 MERCEDES-BENZ E350

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2008 MERCEDES-BENZ E350 do not stand out strongly from the model-year median of 161.

About this comparison →

When problems were reported

Mileage at the reported incident

135 reports with mileage · 38 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 65 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 22 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Seats. Review the 20 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports9 fire reports7 injury reports

Fuel/propulsion System complaints

65 reports
Clear category filter
Mileage unknown · Dec 31, 2025
Electrical SystemFuel/propulsion System

My car displayed all of the issues listed below for the Electrical system recall. The fuel gague went "blank", other gagues acting irradical, the check engine light stay on, etc. My car make and model fall under this recall but have been excluded. I had to pay out of pocket $4678.50 to replace the entire fuel tank due to this a…

Read full complaint

My car displayed all of the issues listed below for the Electrical system recall. The fuel gague went "blank", other gagues acting irradical, the check engine light stay on, etc. My car make and model fall under this recall but have been excluded. I had to pay out of pocket $4678.50 to replace the entire fuel tank due to this and the Manufacture (Mercedes Benz) is refusing to reimburse me. (1) THE FUEL GAUGE READINGS MAY BE INCORRECT; (2) A STUCK FUEL-LEVEL SENSOR MAY NOT BE DISPLAYED IN THE INSTRUMENT CLUSTER; (3) THE OBD SYSTEM MAY CAUSE THE CHECK ENGINE LIGHT TO ILLUMINATE INCORRECTLY; AND, (4) THE SPEEDOMETER MAY BE OUT OF TOLERANCE. IN THE EVENT OF A VEHICLE CRASH, THE ELECTRICAL FUEL PUMP MAY NOT RECEIVE A CRASH SIGNAL THAT IS REQUIRED FOR THE FUEL PUMP TO DISCONNECT AND PREVENT FUTURE FUEL DELIVERY AS DESIGNED.

NHTSA ODI #11708086

Mileage unknown · Sep 27, 2024
Fuel/propulsion System

This is a PZEV vehicle. When the car is filled over 3/4th of the way, the driver's side near the back tire starts to leak the fuel. There was no warning lights, just the smell and the leaks. It's obvious why this is a safety hazard. This was not inspected by anyone other than myself as it was quite obvious after removing the ba…

Read full complaint

This is a PZEV vehicle. When the car is filled over 3/4th of the way, the driver's side near the back tire starts to leak the fuel. There was no warning lights, just the smell and the leaks. It's obvious why this is a safety hazard. This was not inspected by anyone other than myself as it was quite obvious after removing the back seat and accessing the sending unit location. This started after I resolved a fuel pump issue (back in March, resolved this month) Mercedes refused to handle ($3k) and noticed on or around 9/24/24.

NHTSA ODI #11616902

Mileage unknown · May 9, 2024
Electrical SystemFuel/propulsion SystemUnknown Or Other

On [XXX] I was driving and the vehicles stalled in the middle of the street, I couldn’t start it back. I managed to contact AAA and had the vehicle towed to my home because it around 6pm and auto repair shops were closed. Next morning I had AAA towed the vehicle to a local auto repair shop and they told me that fuel pump faile…

Read full complaint

On [XXX] I was driving and the vehicles stalled in the middle of the street, I couldn’t start it back. I managed to contact AAA and had the vehicle towed to my home because it around 6pm and auto repair shops were closed. Next morning I had AAA towed the vehicle to a local auto repair shop and they told me that fuel pump failed. It would have been very dangerous if we were driving on the freeway, not to mention I had my 85 year old mother in the passenger seat. Please help me as I am sure what I need to do now. It’s a Mercedes-Benz model E350 2008. I can be reached at [XXX] my name is [XXX] . My car has 87,200 miles. Thank you in advance for all your helps. INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6)

NHTSA ODI #11587937

Mileage unknown · Apr 12, 2024
Fuel/propulsion System

Smell of gasoline in the cabin and real bad outside of car

NHTSA ODI #11582498

Mileage unknown · Sep 17, 2023
Fuel/propulsion System

Gasoline smell all times inside of the car.

NHTSA ODI #11545003

Mileage unknown · May 1, 2023
Fuel/propulsion System

My car has smelled like gas for the past few years. Also it has not past inspection for the past 2 years. Mercedes said it was due to a defective intake manifold. Paid to replace the intake manifold and Mercedes said 2 new codes appeared. Now the gas tank, fuel pumps, brackets and hoses need to be replaced at a cost of of …

Read full complaint

My car has smelled like gas for the past few years. Also it has not past inspection for the past 2 years. Mercedes said it was due to a defective intake manifold. Paid to replace the intake manifold and Mercedes said 2 new codes appeared. Now the gas tank, fuel pumps, brackets and hoses need to be replaced at a cost of of over 3500. The fuel pumps were replaced in 2014. Not sure why I continue to have problems with fuel pumps and now gas tank. Was informed this year after replacing the intake manifold that there was an extended warranty that concluded December 2022. I think Mercedes should resolve this as other vehicles had this same safety issue.

NHTSA ODI #11519937

Mileage unknown · Jan 28, 2023
Fuel/propulsion System

Very strong gas smell both inside and outside of the car with check engine light on. This happened in May of 2022. Could not park the car inside the garage. Contacted MBUSA, they said there is an extended warranty for this vehicle for this problem, advised me to take it to Mercedes dealer. I took the car to the dealer. They chec…

Read full complaint

Very strong gas smell both inside and outside of the car with check engine light on. This happened in May of 2022. Could not park the car inside the garage. Contacted MBUSA, they said there is an extended warranty for this vehicle for this problem, advised me to take it to Mercedes dealer. I took the car to the dealer. They checked it out and said it is not covered under the extended warranty because it has passed the mileage ceiling for PZEV which I do not know what PZEV is. I checked The NHTSA website, it says 15 years unlimited miles. I had no other choice but to fix the car at the dealer and pay for the cost. A few months later MBUSA sent me a letter telling me although it has passed the mileage I might be eligible for a refund and wanted me to file a claim at the dealership. I did and after over two months the dealer again told me it is not covered. I paid about $1100 for the repair and told MBUSA that the dealer does not honor what the MBUSA letter says. Now even MBUSA does not honor what they wrote me in their own letter. They say if my car was non PZEV it would have been covered? How was it my fault to have a PZEV vehicle? Why did Mercedes had PZEV and non PZEV? How is it the customer fault. Both vehicles have the same issue but why one is covered and the other is not? Please you be the judge.

NHTSA ODI #11504240

Mileage unknown · May 18, 2021
Fuel/propulsion System

Smell Heavy gas smell inside of the vehicle but not in the engine bay. Stronger smell in the back seat. Afraid car my catch fire while driving. Having to drive with windows down so i don't get droggy.

NHTSA ODI #11417652

Mileage unknown · Apr 5, 2021
Fuel/propulsion System

LEAKING GAS TANK PVEZ, MERCEDES WILL NOT REPLACE IT, WAS UNDER RECALL.

NHTSA ODI #11406612

Mileage unknown · Feb 23, 2021
Fuel/propulsion System

WHEN CAR IS FILLED WITH GAS(FULL) , A GASOLINE ODOR CONSUMES MY GARAGE. WHEN WE OPEN GARAGE ALL YOU CAN SMELL IS GASOLINE. WHEN THE CAR GETS LESS THAN 1/2 TANK, THE FUEL ODOR SUBSIDES. USUALLY WHEN I TAKE IT TO DEALER I HAVE 1/4 TANK AND SMELL IS HARD TO DETECT. THIS HAS OCCURRED FOR OVER 2 YEARS BUT SMELL IS GETTING WORSE /ST…

Read full complaint

WHEN CAR IS FILLED WITH GAS(FULL) , A GASOLINE ODOR CONSUMES MY GARAGE. WHEN WE OPEN GARAGE ALL YOU CAN SMELL IS GASOLINE. WHEN THE CAR GETS LESS THAN 1/2 TANK, THE FUEL ODOR SUBSIDES. USUALLY WHEN I TAKE IT TO DEALER I HAVE 1/4 TANK AND SMELL IS HARD TO DETECT. THIS HAS OCCURRED FOR OVER 2 YEARS BUT SMELL IS GETTING WORSE /STRONGER IT STARTING TO GIVE US HEADACHES

NHTSA ODI #11397527

Official recalls

4

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

12V264000 · Suspension:rear

Jun 12, 2012

MERCEDES-BENZ IS RECALLING CERTAIN MODEL YEAR 2007-2009 E350 4MATIC WAGON VEHICLES MANUFACTURED FROM JULY 1, 2006, THROUGH APRIL 30, 2009. A CONNECTING ROD FOR THE LOAD LEVELING REAR SUSPENSION SYSTEM MAY FAIL.

Consequence & remedy

Consequence: IF THIS OCCURS, THE DRIVER MAY HAVE REDUCED VEHICLE CONTROL, INCREASING THE RISK OF A CRASH.

Remedy: MERCEDES-BENZ WILL NOTIFY OWNERS, AND DEALERS WILL REPLACE ALL THE CONNECTING RODS, FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 7, 2012. OWNERS MAY CONTACT MERCEDES-BENZ AT 1-800-367-6372.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un