← New search

2007 MERCEDES-BENZ E350

Owner reports · Recalls · Investigations

More warning signs than most E350 years

Owner complaints for the 2007 MERCEDES-BENZ E350 are substantially higher than the model-year median of 161.

About this comparison →

When problems were reported

Mileage at the reported incident

296 reports with mileage · 53 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 177 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 79 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 28 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

1 crash reports10 fire reports7 injury reports

Fuel/propulsion System complaints

177 reports
Clear category filter
30,960 miles · Apr 29, 2013
Fuel/propulsion System

I FOUND LEAKING LIQUID CLOSE TO THE REAR LEFT WHEEL AND WHEN LIFTING THE REAR WHEEL I FOUND LEAKING LIQUID FROM THE TANK. AFTER SMELLING AND TOUCHING I REALIZE IS GASOLINE . I CHECK IN THE INTERNET FOR SIMILAR PROBLEMS AND I FOUND A LOT OF SAME COMPLAINTS. *TR

NHTSA ODI #10509953

73,000 miles · Apr 26, 2013
Fuel/propulsion System

TL* THE CONTACT OWNS A 2007 MERCEDES BENZ E350. THE CONTACT STATED THAT THERE WERE GASOLINE FUEL FUMES INSIDE VEHICLE. THE VEHICLE WAS TAKEN TO A DEALER AND A DIAGNOSTIC WAS PERFORMED. THE CONTACT WAS ADVISED THAT THE FUEL SENDING UNIT NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT MADE AWARE OF TH…

Read full complaint

TL* THE CONTACT OWNS A 2007 MERCEDES BENZ E350. THE CONTACT STATED THAT THERE WERE GASOLINE FUEL FUMES INSIDE VEHICLE. THE VEHICLE WAS TAKEN TO A DEALER AND A DIAGNOSTIC WAS PERFORMED. THE CONTACT WAS ADVISED THAT THE FUEL SENDING UNIT NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE VIN WAS NOT AVAILABLE. THE FAILURE AND CURRENT MILEAGE WAS 73,000.

NHTSA ODI #10509676

56,000 miles · Apr 21, 2013
Fuel/propulsion System

FUEL SMELL IN CAR. POSSIBLE FUEL LEAK. *TR

NHTSA ODI #10508997

45,000 miles · Apr 19, 2013
Fuel/propulsion System

TL* THE CONTACT OWNS A 2007 MERCEDES BENZ E350. THE CONTACT STATED THAT ONE HOUR AFTER REFUELING, A STRONG GASOLINE FUEL ODOR WOULD EMIT INSIDE OF THE VEHICLE. THE FAILURE RECURRED WHENEVER THE FUEL TANK LEVEL WAS HALF FULL OR GREATER. A CERTIFIED MECHANIC INSPECTED THE VEHICLE AND STATED THAT THE FAILURE COULD HAVE POSSIBLY BEE…

Read full complaint

TL* THE CONTACT OWNS A 2007 MERCEDES BENZ E350. THE CONTACT STATED THAT ONE HOUR AFTER REFUELING, A STRONG GASOLINE FUEL ODOR WOULD EMIT INSIDE OF THE VEHICLE. THE FAILURE RECURRED WHENEVER THE FUEL TANK LEVEL WAS HALF FULL OR GREATER. A CERTIFIED MECHANIC INSPECTED THE VEHICLE AND STATED THAT THE FAILURE COULD HAVE POSSIBLY BEEN RELATED TO THE FUEL TANK DELIVERY. THE VEHICLE WAS IN THE PROCESS OF BEING TAKEN TO AN AUTHORIZED DEALER FOR A SECOND OPINION. THE MANUFACTURER WAS NOT NOTIFIED OF THE PROBLEM. THE APPROXIMATE FAILURE MILEAGE WAS 45,000. THE VIN WAS NOT AVAILABLE.

NHTSA ODI #10508769

95,000 miles · Apr 10, 2013
Fuel/propulsion System

THE VEHICLE'S CHECK ENGINE LIGHT ILLUMINATED AFTER COMMUTE FROM WORK. THE VEHICLE WAS TAKEN TO MERCEDES-BENZ OF EL PASO FOR DIAGNOSTIC TESTING WHICH REVEALED A CRACK IN THE FUEL TANK ALLOWING FUMES TO ESCAPE FROM THE VEHICLE. WHEN TANK IS FILLED, GAS FUMES COULD BE SMELLED THROUGHOUT THE HOUSE IF THE CAR IS PARKED IN THE GARAGE.…

Read full complaint

THE VEHICLE'S CHECK ENGINE LIGHT ILLUMINATED AFTER COMMUTE FROM WORK. THE VEHICLE WAS TAKEN TO MERCEDES-BENZ OF EL PASO FOR DIAGNOSTIC TESTING WHICH REVEALED A CRACK IN THE FUEL TANK ALLOWING FUMES TO ESCAPE FROM THE VEHICLE. WHEN TANK IS FILLED, GAS FUMES COULD BE SMELLED THROUGHOUT THE HOUSE IF THE CAR IS PARKED IN THE GARAGE. FUEL TANK WAS REPLACED AT A COST OF $2400 WITH REPAIRS COMPLETED BY MERCEDES BENZ OF EL PASO IN FEBRUARY 2013. *TR

NHTSA ODI #10505874

48,000 miles · Apr 10, 2013
Fuel/propulsion System

TANK LEAKS GAS WHEN FILLED . FUEL LINK HAS NOT BEEN REPAIRED AT THIS TIME. MERCEDES WILL NOT WARRANTY. *TR

NHTSA ODI #10505845

92,530 miles · Apr 5, 2013
Fuel/propulsion System

STRONG ODOR OF GASOLINE AFTER REFUELING. *TR

NHTSA ODI #10507281

69,200 miles · Apr 5, 2013
Engine And Engine CoolingFuel/propulsion System

PURCHASED CERTIFIED PRE-OWNED CAR IN JUNE 2012. ON OR ABOUT FEB 2013, CAR STARTED HAVING ILLUMINATING ODOR IN THE CABIN THAT RESEMBLED FUEL OR ANTI-FREEZE. GARAGE AND CAR ODOR WAS SO BAD IT ACTUALLY ENTERED MY HOME AND I HAD TO LEAVE THE GARAGE DOOR OPEN TO VENTILATE. WENT ON LINE AND FOUND OTHER OWNERS EXHIBITING EXACT DEFECT. …

Read full complaint

PURCHASED CERTIFIED PRE-OWNED CAR IN JUNE 2012. ON OR ABOUT FEB 2013, CAR STARTED HAVING ILLUMINATING ODOR IN THE CABIN THAT RESEMBLED FUEL OR ANTI-FREEZE. GARAGE AND CAR ODOR WAS SO BAD IT ACTUALLY ENTERED MY HOME AND I HAD TO LEAVE THE GARAGE DOOR OPEN TO VENTILATE. WENT ON LINE AND FOUND OTHER OWNERS EXHIBITING EXACT DEFECT. TOOK VEHICLE TO MERCEDES DEALER AND WAS INFORMED THAT A LEAK FROM THE FUEL TANK WAS THE CAUSE AND IT WAS NOT FROM DAMAGE BUT FROM THE SENDING UNIT AND LINES. THE DEALER INFORMS ME THAT THE REPAIR IS NOT COVERED UNDER THE WARRANTY AND THAT IT WILL COST $2100.00 TO FIX. AFTER READING THE WARRANTY AND CONTACTING MERCEDES DIRECTLY, I CONTACTED THE DEALER AND INFORMED THEM THAT IT IS A COVERED ITEM AND THEY SHOULD MAKE THE REPAIR AS A WARRANTIED ITEM. THEY RE-CHECKED WITH MERCEDES AND CALLED ME BACK AND STATED THAT THEY HAD "DID SOMETHING IN THE SYSTEM TO MAKE IT REJECT" AND IT IS A COVERED REPAIR AND WILL BE FIXED UNDER THE WARRANTY. I AM MAKING THIS COMPLAINT BECAUSE I BELIEVE THAT THE REPLACEMENT UNIT WILL BE THE SAME OEM PART THAT HAS NOT BEEN MODIFIED TO SOLVE THIS FAILURE FROM DUPLICATING LATER. *TR

NHTSA ODI #10507237

73,897 miles · Mar 26, 2013
Fuel/propulsion System

PURCHASED CAR ON 2/12/2013. FILLED CAR UP WITH GAS FOR THE FIRST TIME ON SATURDAY 3/23/2013. GARAGE AND CAR SMELL LIKE GAS SO BAD IT ACTUALLY ENTERED MY HOME AND I HAD TO LEAVE THE GARAGE DOOR OPEN TO VENTILATE. WENT ON LINE AND FOUND THAT THERE ARE SOME LAW SUITS AGAINST MERCEDES FOR THIS DEFECT AND THEY ARE REPLACING THE GA…

Read full complaint

PURCHASED CAR ON 2/12/2013. FILLED CAR UP WITH GAS FOR THE FIRST TIME ON SATURDAY 3/23/2013. GARAGE AND CAR SMELL LIKE GAS SO BAD IT ACTUALLY ENTERED MY HOME AND I HAD TO LEAVE THE GARAGE DOOR OPEN TO VENTILATE. WENT ON LINE AND FOUND THAT THERE ARE SOME LAW SUITS AGAINST MERCEDES FOR THIS DEFECT AND THEY ARE REPLACING THE GAS TANKS WITH STILL DEFECTED GAS TANKS AND CHARGING CLIENTS FOR THEM. *TR

NHTSA ODI #10504510

19,900 miles · Mar 25, 2013
Fuel/propulsion System

FUEL SMELL INSIDE AND OUTSIDE THE CAR WHEN THE TANK WAS FULL. FUEL SMELL GRADUALLY LESSENED WHEN THE TANK WAS ABOUT 3/4 TO 1/2 EMPTY. TOOK THE CAR TO MB DEALER AND THEY CHANGED THE FUEL SENDING UNIT UNDER THE REAR SEAT BEHIND THE DRIVER. IT COST ABOUT $700. I KEPT THE FUEL SENDING UNIT AND LOOKING AT IT UNDER MAGNIFICATION, …

Read full complaint

FUEL SMELL INSIDE AND OUTSIDE THE CAR WHEN THE TANK WAS FULL. FUEL SMELL GRADUALLY LESSENED WHEN THE TANK WAS ABOUT 3/4 TO 1/2 EMPTY. TOOK THE CAR TO MB DEALER AND THEY CHANGED THE FUEL SENDING UNIT UNDER THE REAR SEAT BEHIND THE DRIVER. IT COST ABOUT $700. I KEPT THE FUEL SENDING UNIT AND LOOKING AT IT UNDER MAGNIFICATION, I CAN SEE BAD WORKMANSHIP AROUND THE SENDING UNIT NOT BEING SEALED PROPERLY, IT WAS BAD FROM THE MOMENT IT WAS PLACED IN THE CAR. THIS ITEM SHOULD NOT GO BAD ON A CAR LESS THAN 6 YEARS OLD THAT HAS ONLY ABOUT 20,000 MILES AND ALWAYS GARAGED. SHAME ON MERCEDES BENZ THAT DID NOT RECALL THIS ITEM. *TR

NHTSA ODI #10504413

Official recalls

5

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

21V196000 · Visibility:sun/moon Roof Assembly

Mar 19, 2021

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2006-2007 C350, C230, C280, CLK350, E320CDI, E350 Wagon, E350, 2006 C55 AMG, CLK500, CLS500, CLS55 AMG, E500 Wagon, E500, E55 AMG, 2007 CLK550, CLS550, CLS63 AMG, E550, E63 AMG, and E63 Wagon AMG vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly causing the glass panel to detach from the vehicle.

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. Owner letters were mailed May 7, 2021. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of recall number 19V-918. MBUSA's number for this recall is 2021040012.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

12V264000 · Suspension:rear

Jun 12, 2012

MERCEDES-BENZ IS RECALLING CERTAIN MODEL YEAR 2007-2009 E350 4MATIC WAGON VEHICLES MANUFACTURED FROM JULY 1, 2006, THROUGH APRIL 30, 2009. A CONNECTING ROD FOR THE LOAD LEVELING REAR SUSPENSION SYSTEM MAY FAIL.

Consequence & remedy

Consequence: IF THIS OCCURS, THE DRIVER MAY HAVE REDUCED VEHICLE CONTROL, INCREASING THE RISK OF A CRASH.

Remedy: MERCEDES-BENZ WILL NOTIFY OWNERS, AND DEALERS WILL REPLACE ALL THE CONNECTING RODS, FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 7, 2012. OWNERS MAY CONTACT MERCEDES-BENZ AT 1-800-367-6372.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un