← New search

2003 MERCEDES-BENZ Amg E55

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Amg E55 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

60 reports with mileage · 10 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 40 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 3 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

What owners actually said

70 reports
12,000 miles · May 15, 2013
Fuel System, GasolineFuel/propulsion System

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55 AMG. THE CONTACT STATED THAT AFTER REFUELING, GASOLINE WOULD LEAK FROM THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS WHERE IT WAS ADVISED TO THE CONTACT THAT THE FUEL TANK WAS DEFECTIVE. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. T…

Read full complaint

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55 AMG. THE CONTACT STATED THAT AFTER REFUELING, GASOLINE WOULD LEAK FROM THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS WHERE IT WAS ADVISED TO THE CONTACT THAT THE FUEL TANK WAS DEFECTIVE. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 120,000. *TR

NHTSA ODI #10512254

94,764 miles · Apr 10, 2013
Fuel System, GasolineFuel/propulsion System

STRONG ODOR OF GASOLINE IN THE INTERIOR OF THE CAR AFTER FILLING THE TANK. ODOR HAS PERSISTED FOR A WEEK. REFER TO NHTSA ACTION NUMBER PE12001. *TR

NHTSA ODI #10505868

117,000 miles · Apr 10, 2013
Fuel/propulsion System

FUEL TANK AND PUMP ASSEMBLY REQUIRED REPLACEMENT DUE TO MASSIVE FUEL LEAK. *TR

NHTSA ODI #10505835

45,000 miles · Apr 1, 2013
Fuel/propulsion System

BEGAN NOTING A STRONG GAS SMELL INSIDE MY VEHICLE AFTER REFUELING. ON INVESTIGATION THE BACK SEAT FOAM WAS COMPLETELY SATURATED FROM A LEAK AT THE SEAL ON THE TOP OF THE GAS TANK UNDER THE SEAT. RESULTED IN A COSTLY REPAIR BILL. AT THE TIME I READ ONLINE OF MANY, MANY SIMILAR SITUATIONS EXPERIENCED BY OTHER MB AMG E55 OWNERS, A…

Read full complaint

BEGAN NOTING A STRONG GAS SMELL INSIDE MY VEHICLE AFTER REFUELING. ON INVESTIGATION THE BACK SEAT FOAM WAS COMPLETELY SATURATED FROM A LEAK AT THE SEAL ON THE TOP OF THE GAS TANK UNDER THE SEAT. RESULTED IN A COSTLY REPAIR BILL. AT THE TIME I READ ONLINE OF MANY, MANY SIMILAR SITUATIONS EXPERIENCED BY OTHER MB AMG E55 OWNERS, AS WELL AS THEIR FRUSTRATION THAT MB WAS NOT TAKING ANY RESPONSIBILITY FOR THIS. THUS, I WAS FORCED TO PAY FOR THE REPAIRS MYSELF. NO PROBLEM SINCE, ALTHOUGH I AM HESITANT TO FILL THE TANK COMPLETELY AS MANY REPORT A RECURRENCE A COUPLE YEARS AFTER THEIR INITIAL REPAIR. PLEASE ADVISE IF MB RECOGNIZES THIS APPARENT DEFECT AND ISSUES A RECALL. THANK YOU. *TR

NHTSA ODI #10505178

40,000 miles · Mar 27, 2013
Fuel/propulsion System

FUEL LEAKS FROM TANK WHEN IT IS FILLED TO THE TOP. CAR HAS BEEN TO DEALER AND HAD FUEL TANK SEALS REPLACED TWICE. FUEL PUMPS, GAUGE AND HOSE SYSTEM WAS ALSO REPLACED FOR $1,500. STRONG ODOR OF GASOLINE IF THE CAR IS PARKED IN MY GARAGE AFTER FILLING TANK. I KEPT THE PUMP ASSEMBLY AS A SOUVENIR AND SEE THAT MANY PARTS ARE BRI…

Read full complaint

FUEL LEAKS FROM TANK WHEN IT IS FILLED TO THE TOP. CAR HAS BEEN TO DEALER AND HAD FUEL TANK SEALS REPLACED TWICE. FUEL PUMPS, GAUGE AND HOSE SYSTEM WAS ALSO REPLACED FOR $1,500. STRONG ODOR OF GASOLINE IF THE CAR IS PARKED IN MY GARAGE AFTER FILLING TANK. I KEPT THE PUMP ASSEMBLY AS A SOUVENIR AND SEE THAT MANY PARTS ARE BRITTLE AND PRONE TO CRACKING. MATERIALS IN FUEL PUMPING SYSTEM APPEAR TO BE INAPPROPRIATE FOR DRIVING IN HOT FLORIDA CLIMATE. CAR HAS BEEN KEPT IN GARAGE SINCE NEW (EXCEPT AFTER FILLING GAS TANK). *TR

NHTSA ODI #10504746

73,000 miles · Dec 22, 2012
Fuel/propulsion System

1ST INCIDENT WAS WHILE DRIVING ALONG ON THE EXPRESSWAY AND NOTICED A SLIGHT SCENT OF RAW FUEL,, AS I ARRIVED HOME AND PARKED IN THE GARAGE, EXITING THE VEHICLE THE SMELL OF FUEL WAS MORE EVIDENT, WHEN I LOOK UNDER THE VEHICLE, I SEE A PUDDLE OF GAS STEADILY LEAKING FROM THE FUEL TANK AREA, I CLEANED UP THE MESS AND IMMEDIATELY H…

Read full complaint

1ST INCIDENT WAS WHILE DRIVING ALONG ON THE EXPRESSWAY AND NOTICED A SLIGHT SCENT OF RAW FUEL,, AS I ARRIVED HOME AND PARKED IN THE GARAGE, EXITING THE VEHICLE THE SMELL OF FUEL WAS MORE EVIDENT, WHEN I LOOK UNDER THE VEHICLE, I SEE A PUDDLE OF GAS STEADILY LEAKING FROM THE FUEL TANK AREA, I CLEANED UP THE MESS AND IMMEDIATELY HAD IT INSPECTED, INSPECTION DETERMINED THAT PRIMARY FUEL PUMP SENDING UNIT WAS LEAKING CAUSING FUEL TO ACCUMULATE IN THE FUEL TANK AREA DIRECTLY UNDERNEATH THE LEFT REAR PASSENGER SEAT AND OVERFLOWING OUT THROUGH THE CHASSIS WHEREVER IT COULD FIND A WAY OUT, REPAIR REQUIRED COMPLETE FUEL PUMP WITH SENDING UNIT, AS IT IS A ONE PIECE DESIGN, AFTER ALL SAID AND DONE, REPAIR ESTIMATE $1,800. 2ND INCIDENT, 8/?/2012 SAME AS DESCRIBED IN 1ST INCIDENT WITH THE EXCEPTION OF FUEL LEAK OCCURRED WHILE REFUELING AT THE GAS STATION,, NO PUDDLE, BUT FAINT SMELL,, DROVE HOME, PARKED IN THE GARAGE, SMELLED FUEL MORE, LOOKING UNDER CAR, OBSERVED GROWING PUDDLE OF FUEL. HAD VEHICLE INSPECTED, FUEL LEAKING FROM AROUND FUEL PUMP HOUSING, DETERMINATION WAS FUEL PUMP HOUSING SEAL REPLACEMENT, WHICH AGAIN REQUIRED FUEL PUMP ASSEMBLY REMOVAL AND RE-INSTALL FOR REPLACEMENT OF NEW SEAL, OUT OF WARRANTY, PAST 1YEAR WARRANTY BY A FEW MONTHS, $1200 REPAIR, MOSTLY LABOR, PART COST $20....SEEMED TO CORRECT FUEL LEAK FOR NOW.....FUEL SMELL HAS NOT GONE AWAY.... *TR

NHTSA ODI #10489513

89,000 miles · Nov 27, 2012
Fuel/propulsion System

UPON FILLING THE FUEL TANK, THERE IS AN OBVIOUS ODOR OF FUEL WHICH IS NOTICED OUTSIDE THE VEHICLE BUT DIFFICULT TO PINPOINT WHERE IT'S COMING FROM. I WENT TO THE DEALER AND THEY SAID ALL THE RECALLS OR SAFETY RECALLS WERE PERFORMED ON MY VEHICLE ALREADY. BUT THE ODOR OF GAS IS VERY STRONG AND NOT RESOLVED YET. *TR

NHTSA ODI #10486211

101,000 miles · Nov 10, 2012
Fuel/propulsion System

MOST TIMES WHEN I FILL THE VEHICLE WITH GAS A STRONG FUEL ODOR EMANATES FROM INSIDE THE VEHICLE AND OUTSIDE THE VEHICLES SPECIFICALLY AT THE LEFT REAR CORNER BUT IT CAN ALSO BE SMELLED ON THE RIGHT SIDE. MOST TIMES THE VAPOR WILL DISAPPEAR WITHIN A FEW DAYS. SOMETIMES (CURRENTLY) THE SMELL HASN'T DISAPPEARED IN OVER A WEEK (AND …

Read full complaint

MOST TIMES WHEN I FILL THE VEHICLE WITH GAS A STRONG FUEL ODOR EMANATES FROM INSIDE THE VEHICLE AND OUTSIDE THE VEHICLES SPECIFICALLY AT THE LEFT REAR CORNER BUT IT CAN ALSO BE SMELLED ON THE RIGHT SIDE. MOST TIMES THE VAPOR WILL DISAPPEAR WITHIN A FEW DAYS. SOMETIMES (CURRENTLY) THE SMELL HASN'T DISAPPEARED IN OVER A WEEK (AND THE VEHICLE IS RUNNING ON LOW FUEL). *TR

NHTSA ODI #10483923

47,488 miles · Oct 24, 2012
Fuel/propulsion System

FUEL PUMP ASSEMBLY WAS LEAKING RAW FUEL UNDER CAR CAUSING EXPLOSION HAZARD THAT COULD LEAD TO FATALITY. *TR

NHTSA ODI #10482041

68,849 miles · Oct 20, 2012
Fuel/propulsion System

EVERY TIME I FILL THE TANK, I GET A STRONG FUEL SMELL. RECALL WAS PERFORMED INSERT IN FUEL FITTING, NOT THE PROBLEM. SERVICE CENTER FOUND "COVER PLATES LEAKING ON BOTH SIDES, REPLACED FUEL PUMPS, INSTALLED UPDATED CONTACT PLATE AND SEAL. CHECKED FOR LEAKS AND NONE FOUND." FILLED TANK AND STRONG FUEL SMELL RETURNED IMMEDIATELY. F…

Read full complaint

EVERY TIME I FILL THE TANK, I GET A STRONG FUEL SMELL. RECALL WAS PERFORMED INSERT IN FUEL FITTING, NOT THE PROBLEM. SERVICE CENTER FOUND "COVER PLATES LEAKING ON BOTH SIDES, REPLACED FUEL PUMPS, INSTALLED UPDATED CONTACT PLATE AND SEAL. CHECKED FOR LEAKS AND NONE FOUND." FILLED TANK AND STRONG FUEL SMELL RETURNED IMMEDIATELY. FOUND OUT BY EXPERIENCE NEVER TO PARK THE VEHICLE IN THE GARAGE WITH A FULL TANK OR THE HOUSE WILL BE FILLED WITH FUEL SMELL. POOR DESIGN FUEL SYSTEM IN THE E CLASS MERCEDES, SOMEDAY ONE WILL CAUSE AN EXPLOSION, DO NOT PARK IN ATTACHED/BASEMENT GARAGE! *TR

NHTSA ODI #10481268

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

PE12001 · Fuel System (tank/sender) Leakage

Opened Jan 23, 2012 · Closed Mar 18, 2013

Status: closed (inferred from source dates) · Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.

Additional source detail variants (2)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.