← New search

2003 MERCEDES-BENZ Amg E55

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Amg E55 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

60 reports with mileage · 10 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 40 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 3 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

Fuel/propulsion System complaints

40 reports
Clear category filter
39,625 miles · Dec 31, 2014
Fuel/propulsion System

REFERENCE THE NHTSA ACTION# PE12001 THERE IS A FUEL LEAK AT ONE OR BOTH OF THE FUEL SENDING UNITS AND AT ONE OR BOTH OF THE FUEL PUMPS LOCATED IN THE GAS TANK OF THIS CAR. WHEN FILLING THE GAS TANK TO FULL, GAS LEAKS AND PRODUCES A VERY STRONG GASOLINE SMELL INSIDE AND AROUND THE EXTERIOR OF THE CAR. I HAVE REMOVED THE REA…

Read full complaint

REFERENCE THE NHTSA ACTION# PE12001 THERE IS A FUEL LEAK AT ONE OR BOTH OF THE FUEL SENDING UNITS AND AT ONE OR BOTH OF THE FUEL PUMPS LOCATED IN THE GAS TANK OF THIS CAR. WHEN FILLING THE GAS TANK TO FULL, GAS LEAKS AND PRODUCES A VERY STRONG GASOLINE SMELL INSIDE AND AROUND THE EXTERIOR OF THE CAR. I HAVE REMOVED THE REAR SEAT TO GAIN ACCESS TO THE UNITS AND I HAVE OBSERVED STANDING GASOLINE ON THE TOP SURFACE OF THE SENDING UNIT SEALS. THERE ARE ELECTRICAL CONNECTIONS INSIDE OF THESE UNITS AND THEY APPEAR TO HAVE BEEN SHORTING DUE TO THE LEAK. THIS IS POTENTIALLY A VERY HAZARDOUS, LIFE THREATENING CONDITION. *JS

NHTSA ODI #10669345

168,600 miles · Dec 8, 2014
Fuel/propulsion System

THIS VEHICLE WAS PREVIOUSLY SERVICED IN 2008 FOR THE SAME ISSUE AS PART OF A RECALL CAMPAIGN BY MERCEDES-BENZ, #2008-020001. I WAS NOT THE OWNER AT THE TIME. THE IDENTICAL ISSUE IS NOW PRESENT ONCE AGAIN, VERY STRONG GASOLINE ODOR IN THE INTERIOR, AND A LESS-PRESENT ODOR AT THE EXTERIOR. THE DEFECTIVE FUEL SENDER UNITS WILL N…

Read full complaint

THIS VEHICLE WAS PREVIOUSLY SERVICED IN 2008 FOR THE SAME ISSUE AS PART OF A RECALL CAMPAIGN BY MERCEDES-BENZ, #2008-020001. I WAS NOT THE OWNER AT THE TIME. THE IDENTICAL ISSUE IS NOW PRESENT ONCE AGAIN, VERY STRONG GASOLINE ODOR IN THE INTERIOR, AND A LESS-PRESENT ODOR AT THE EXTERIOR. THE DEFECTIVE FUEL SENDER UNITS WILL NOW BE REPLACED AT MY PERSONAL EXPENSE, HOWEVER SINCE THIS IS A REPEAT OF A PREVIOUS ISSUE WHICH HAD ALREADY WARRANTED A RECALL, I BELIEVE THIS SHOULD BE THE RESPONSIBILITY OF MERCEDES-BENZ USA. *TR

NHTSA ODI #10662873

84,575 miles · Dec 7, 2014
Fuel/propulsion System

I PARKED MY CAR IN MY GARAGE AND SMELLED GASOLINE. I LOOKED UNDER THE CAR AND IT WAS LEAKING GASOLINE. IT LEFT A BIG PUDDLE AND WILL NOT STOP. *TR

NHTSA ODI #10662601

52,400 miles · Nov 2, 2014
Fuel/propulsion System

FILLED MY JUST PURCHASED 2003 E55 AMG WITH GASOLINE ON 10/30/14 AND DROVE STRAIGHT HOME. AFTER A FEW MINUTES MY BROTHER TOLD ME THE GARAGE HAD A STRONG GASOLINE SMELL. DROVE TO WORK THE NEXT MORNING AND NOTICED THE SMELL WAS EXTREMELY STRONG IN THE CAR AND LEFT WINDOWS DOWN TO VENTILATE. DROVE HOME WITH WINDOWS DOWN AND STILL…

Read full complaint

FILLED MY JUST PURCHASED 2003 E55 AMG WITH GASOLINE ON 10/30/14 AND DROVE STRAIGHT HOME. AFTER A FEW MINUTES MY BROTHER TOLD ME THE GARAGE HAD A STRONG GASOLINE SMELL. DROVE TO WORK THE NEXT MORNING AND NOTICED THE SMELL WAS EXTREMELY STRONG IN THE CAR AND LEFT WINDOWS DOWN TO VENTILATE. DROVE HOME WITH WINDOWS DOWN AND STILL NOTICED SMELL THAT SEEMED TO BE COMING FROM BACK SEAT OF CAR. ENTERED CAR AND "GASOLINE SMELL" INTO INTERNET SEARCH TO FIND THERE IS A LARGE SCALE ISSUE, INVESTIGATION, AND LAWSUIT. WHEN PICKING THE CAR UP FROM DEALER I NOTICED THE ENTIRE REAR SEAT BOTTOM WAS NOT ATTACHED. THOUGHT IT MAY HAVE BEEN DUE TO AN INSPECTION. HOWEVER, IT TURNS OUT THAT THE ACCESS PANEL FOR THE FUEL SENDING UNIT IS DIRECTLY UNDER THE SEAT. AFTER LEARNING THIS I REMOVED THE REAR SEAT TO FIND GASOLINE ON THE ACCESS PANEL. REMOVED THE PANEL TO FIND A PUDDLE OF GASOLINE ON TOP OF THE TANK AROUND THE SENDING UNIT. IMMEDIATELY CALLED THE DEALER AND THEY SAID TO PARK THE CAR AND A TOW TRUCK WOULD DELIVER IT TO THEM. THEN THE DEALER CALLED AND PROVIDED A NUMBER FOR ME TO CALL MERCEDES BENZ USA TO ARRANGE A TOW TRUCK. MERCEDES ARRANGED THE TOW TRUCK AND HAULED THE JUST PURCHASED CAR BACK TO DEALER. DEALER IS SUPPOSED TO BE CHECKING IT ON MONDAY 11/3/14 TO LET ME KNOW THE STATUS. *TR

NHTSA ODI #10651898

82,000 miles · Oct 4, 2014
Fuel/propulsion System

I GOT HOME FROM THE STORE SMELT GAS THOUGHT NOTHING OF IT AT FIRST. THE NEXT DAY I WAS DRIVING MY VEHICLE WITH THE WINDOWS DOWN GOT A BIG SMELL OF FUEL, THAT GOT ME THINKING. LATER THAT DAY WHEN I GOT HOME I STARTED SMELLING AROUND MY VEHICLE. OPENED TRUNK SMELT GAS. THEN I SMELT BOTH REAR WHEEL WELLS AND SMELLED A STRONG FUEL O…

Read full complaint

I GOT HOME FROM THE STORE SMELT GAS THOUGHT NOTHING OF IT AT FIRST. THE NEXT DAY I WAS DRIVING MY VEHICLE WITH THE WINDOWS DOWN GOT A BIG SMELL OF FUEL, THAT GOT ME THINKING. LATER THAT DAY WHEN I GOT HOME I STARTED SMELLING AROUND MY VEHICLE. OPENED TRUNK SMELT GAS. THEN I SMELT BOTH REAR WHEEL WELLS AND SMELLED A STRONG FUEL ODOR ON THE DRIVE SIDE REAR WHEEL. FURTHER INVESTIGATION I GOT UNDER THE VEHICLE TO CHECK IT OUT. I COULD SEE FUEL RUNNING DOWN THE SIDE OF MY FUEL TANK. SO I REMOVED MY REAR SEAT AND THE CAP UNDER THE SEAT TO SEE THE FUEL SENDING UNIT FROM ABOVE. WHEN I REMOVED THAT THERE WAS A STREAM OF FUEL SHOOTING OUT OF MY SENDING UNIT. I DID SOME RESEARCH ON THIS CLAIM AND I FOUND OUT ITS A COMMON OCCURRENCE. THAT THERE WAS A PREVIOUS RECALL AND THAT DIDN'T DO THE FIX. I HAVE A PICTURE OF THE SENDING UNIT SHOOTING THE SPRAY OF FUEL BUT THERE IS NO AREA TO UPLOAD IT ON HERE. I WOULD LIKE TO KNOW WHAT IS GOING WITH THIS. THANK YOU. *TR

NHTSA ODI #10641361

98,000 miles · Aug 12, 2014
Fuel/propulsion System

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55. THE CONTACT NOTICED A LEAK UNDERNEATH THE VEHICLE AND STATED THAT THERE WERE PUDDLES ON SEVERAL OCCASIONS. THE DEALER STATED THAT THE FUEL SENDING UNIT NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEA…

Read full complaint

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55. THE CONTACT NOTICED A LEAK UNDERNEATH THE VEHICLE AND STATED THAT THERE WERE PUDDLES ON SEVERAL OCCASIONS. THE DEALER STATED THAT THE FUEL SENDING UNIT NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED AND THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 98,000.

NHTSA ODI #10621823

75,842 miles · May 15, 2014
Fuel/propulsion System

STRONG SMELL OF FUEL AND STANDING GASOLINE UNDER THE REAR SEATS. *TR

NHTSA ODI #10588523

61,147 miles · Apr 28, 2014
Fuel/propulsion System

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55. THE CONTACT STATED THAT HE NOTICED A STRONG GASOLINE ODOR INSIDE THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS WHERE THE CONTACT WAS ADVISED THAT THE FUEL PUMP WAS FRACTURED AND NEEDED TO BE REPLACED ALONG WITH THE RIGHT REAR SENDING UNIT. THE MANUFACTURER WAS NOTIF…

Read full complaint

TL* THE CONTACT OWNS A 2003 MERCEDES BENZ E55. THE CONTACT STATED THAT HE NOTICED A STRONG GASOLINE ODOR INSIDE THE VEHICLE. THE VEHICLE WAS TAKEN TO THE DEALER FOR DIAGNOSIS WHERE THE CONTACT WAS ADVISED THAT THE FUEL PUMP WAS FRACTURED AND NEEDED TO BE REPLACED ALONG WITH THE RIGHT REAR SENDING UNIT. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE VEHICLE WAS REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 61,147 AND THE CURRENT MILEAGE WAS UNKNOWN. UPDATED 06/10/14*LJ UPDATED 8/23/2017*CN

NHTSA ODI #10585252

150,000 miles · Mar 23, 2014
Fuel/propulsion System

LEAKING FUEL IN CAR AROUND NECK OF FUEL TANK /SENDING UNIT. *TR

NHTSA ODI #10574260

Mileage unknown · Jan 1, 2014
Fuel/propulsion System

I HAVE OWNED THE VEHICLE FOR OVER A YEAR NOW, AND EVER SINCE THE FIRST TIME I FILLED UP MY FUEL TANK, I NOTICED A STRONG FUEL SMELL IN THE VEHICLE. SO MUCH THAT I COULD NOT BE IN THE CAR AND WOULD HAVE TO DRIVE WITH WINDOWS OPEN AND SUNROOF OPENED SO THE SMELL CAN GO AWAY. I TOOK THE CAR TO MERCEDES-BENZ OF WICHITA, KS AND EXPLA…

Read full complaint

I HAVE OWNED THE VEHICLE FOR OVER A YEAR NOW, AND EVER SINCE THE FIRST TIME I FILLED UP MY FUEL TANK, I NOTICED A STRONG FUEL SMELL IN THE VEHICLE. SO MUCH THAT I COULD NOT BE IN THE CAR AND WOULD HAVE TO DRIVE WITH WINDOWS OPEN AND SUNROOF OPENED SO THE SMELL CAN GO AWAY. I TOOK THE CAR TO MERCEDES-BENZ OF WICHITA, KS AND EXPLAINED MY ISSUE AND THEY SIMPLY SAID THAT THE FUEL SENDING UNIT MIGHT BE RELEASING VAPOR INTO THE CABIN AND THAT IT WOULD NEED TO BE REPLACED. I ASKED IF IT WAS A RECALL ITEM AND COVERED BY THEM, THEY TOLD ME NO AND THAT IT WOULD BE AN OUT OF POCKET EXPENSE AT OVER 1000$. I WAS NOT ABLE TO AFFORD THE REPAIRS AT THE TIME SO I SIMPLY DID NOT FILL THE FUEL TANK TO THE TOP FROM THAT POINT ON. ON OCTOBER OF 2013 THOUGH, I PARK AT A LAUNDRY MAT FACILITY AND GO INSIDE. AFTER A COUPLE MINUTES AN EMPLOYEE COMES IN ASKING WHO IS THE OWNER OF A SILVER MERCEDES (MY CAR) STATING THAT IT IS LEAKING FUEL. I RUN OUTSIDE AND NOTICE A HUGE PUDDLE UNDER MY REAR LEFT SIDE OF THE CAR WITH A STEADY STREAM OF FUEL COMING DOWN. I BECAME ALARMED AND BEGAN TO FIND WHERE THE LEAK WAS COMING FROM. I ENDED UP REMOVING THE BACK LOWER SEAT AND GAINED ACCESS TO THE FUEL SENDING UNIT UNDER THE SEAT AND NOTICED THERE WAS FUEL EVERYWHERE AND LEAKING FROM THE TOP OF THE SENDING UNIT. I TOOK PICS AND A VIDEO SO I CAN SHOW THE DEALER THE NEXT DAY. WHEN I SHOWED THE SERVICE MANAGER THE PICTURES AND VIDEO, THEY SAID "WOW, THAT'S BAD. LOOKS LIKE YOU 'RE GOING TO NEED TO REPLACE IT" ONCE AGAIN I ASKED IF THAT QUALIFIED TO BE REPLACED AT NO COST BY THE DEALER SINCE IT IS A MANUFACTURER FLAW AND A SERIOUS SAFETY CONCERN WITH POSSIBLE FIRE OR EXPLOSION WAITING TO OCCUR AND THEY SIMPLY SAID NO AND WOULD NOT TRY TO HELP ME WITH THE ISSUE. I HAVE SEARCHED THIS ISSUE ON THE INTERNET TO FIND NUMEROUS OTHER DRIVERS WITH SAME ISSUE AND THE DEALER WOULD NOT HELP THEM AS WELL. SOMETHING NEEDS TO BE DONE. *TR

NHTSA ODI #10558093

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

2

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

PE12001 · Fuel System (tank/sender) Leakage

Opened Jan 23, 2012 · Closed Mar 18, 2013

Status: closed (inferred from source dates) · Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.

Additional source detail variants (2)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation based on 20 consumer reports.All of the vehicles were E55 AMG models and the complainants alleged fuel leaks or a strong odor of gasoline both inside and outside of their vehicle, particularly after refueling.Some complainants alleged that the leaks may be related to a 2008 Mercedes Benz emission recall (Campaign No. 2008020001) on the fuel filter module. This recall pertained to model years 2003-2006 E and CLS AMG models only.These AMG models use a different fuel pump and fuel filter module than the non-AMG E-class, however, they share other fuel system components, including the fuel tank.Since opening the investigation ODI has received an additional 350 reports relevant to this investigation.Of those reports, 116 reports are on the E55 AMG model.The remaining 234 reports are on other E-class models (i.e., E320, E350, E500, E550 and E63) which are now included in the scope of EA13-003.The investigation has been upgraded to Engineering Analysis, EA13-003, for further study.The ODI reports cited above can be reviewed at www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the identification (ODI) numbers cited on the following page.