← New search

2008 Mercedes Benz E550

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all E550 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 9 of 15 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 5 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel System, Gasoline. Review the 3 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Wheels. Review the 2 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports1 injury reports

Fuel/propulsion System complaints

5 reports
Clear category filter
Mileage unknown · Jan 23, 2025
Fuel/propulsion System

The seal that connects the fuel level sensor to the fuel tank has failed, allowing fuel to leak onto the top of the tank when it’s filled. This creates a serious risk of fire or explosion. Unfortunately, Mercedes does not offer a remedy unless you pay a prohibitively high fee.

NHTSA ODI #11638060

Mileage unknown · May 3, 2024
Fuel/propulsion System

I filled the vehicle up with gas and it started smelling very strong of gas for the next two weeks and I discovered gas underneath the driver's rear seat... I cleaned up the gas but continued to smell strong fuel Vapors and I'm just below three quarters of a tank the 15-year warranty is over. The Mercedes dealer says that they c…

Read full complaint

I filled the vehicle up with gas and it started smelling very strong of gas for the next two weeks and I discovered gas underneath the driver's rear seat... I cleaned up the gas but continued to smell strong fuel Vapors and I'm just below three quarters of a tank the 15-year warranty is over. The Mercedes dealer says that they can't do anything for free and I feel this is a safety issue that needs to be rectified before someone dies in an explosion... no warning lights showed up but it is a common problem on the E-Class due to a cracked fuel filter housing module.

NHTSA ODI #11586911

160,000 miles · Sep 30, 2019
Fuel/propulsion System

TL* THE CONTACT OWNS A 2008 MERCEDES-BENZ E550. WHILE OPERATING THE VEHICLE, THE FUEL GAUGE DISPLAYED INACCURATE FUEL LEVELS AND A STRONG ODOR OF FUEL WAS PRESENT COMING FROM THE EXHAUST. THE VEHICLE WAS TAKEN TO MERCEDES-BENZ OF AUSTIN (6757 AIRPORT BLVD, AUSTIN, TX) WHERE IT WAS DIAGNOSED THAT THE FUEL LEVELING SENSOR WAS FAUL…

Read full complaint

TL* THE CONTACT OWNS A 2008 MERCEDES-BENZ E550. WHILE OPERATING THE VEHICLE, THE FUEL GAUGE DISPLAYED INACCURATE FUEL LEVELS AND A STRONG ODOR OF FUEL WAS PRESENT COMING FROM THE EXHAUST. THE VEHICLE WAS TAKEN TO MERCEDES-BENZ OF AUSTIN (6757 AIRPORT BLVD, AUSTIN, TX) WHERE IT WAS DIAGNOSED THAT THE FUEL LEVELING SENSOR WAS FAULTY AND THE FUEL TANK NEEDED TO BE REPLACED. THE VEHICLE WAS REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED OF THE FAILURE. THE FAILURE MILEAGE WAS 160,000. THE VIN WAS UNKNOWN.

NHTSA ODI #11258982

Mileage unknown · Jan 3, 2017
Fuel/propulsion System

I HAVE BEEN REPORTED TO HAVE A FUEL LEAK.

NHTSA ODI #10939483

80,000 miles · Dec 5, 2013
Fuel/propulsion System

TL* THE CONTACT OWNS A 2008 MERCEDES E550. THE CONTACT STATED THAT AFTER REFUELING, A STRONG GASOLINE ODOR WAS PRESENT OUTSIDE OF THE VEHICLE. THE CONTACT INFORMED THE DEALER OF THE PROBLEM. THE VEHICLE WAS NOT DIAGNOSED OR REPAIRED. THE MANUFACTURER WAS NOT NOTIFIED. THE FAILURE MILEAGE WAS 80,000.

NHTSA ODI #10554961

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un