← New search

2003 Mercedes Benz E500

Owner reports · Recalls · Investigations

More warning signs than most E500 years

Owner complaints for the 2003 Mercedes Benz E500 are substantially higher than the model-year median of 50.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all E500 years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

All reported categories

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

101 reports with mileage · 24 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Service Brakes. Review the 29 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Fuel/propulsion System. Review the 27 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Suspension. Review the 19 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

4 crash reports0 fire reports5 injury reports

Fuel System, Gasoline complaints

14 reports
Clear category filter
168,715 miles · Jul 20, 2015
Fuel System, Gasoline

MY VEHICLE STARTED PUTTERING AND FINALLY SHUT OFF. I HAD IT TOWED TO THE NEAREST MERCEDES BENZ SHOP LOCATED ON INDEPENDENCE DRIVE IN CHARLOTTE. AFTER THE DIAGNOSTIC, I WAS TOLD THAT THE FUEL PUMP WAS BAD. I INFORMED THE SERVICE ADVISOR COLTON AND THE SERVICE MANAGER TODD ABOUT THE EXTENDED WARRANTY ON THE COMPONENTS OF THE FU…

Read full complaint

MY VEHICLE STARTED PUTTERING AND FINALLY SHUT OFF. I HAD IT TOWED TO THE NEAREST MERCEDES BENZ SHOP LOCATED ON INDEPENDENCE DRIVE IN CHARLOTTE. AFTER THE DIAGNOSTIC, I WAS TOLD THAT THE FUEL PUMP WAS BAD. I INFORMED THE SERVICE ADVISOR COLTON AND THE SERVICE MANAGER TODD ABOUT THE EXTENDED WARRANTY ON THE COMPONENTS OF THE FUEL SYSTEM. I WAS DENIED WARRANTY COVERAGE BECAUSE THEY STATED THAT THE FUEL TANK HAD TO BE CRACKED BEFORE THEY WOULD HONOR THE WARRANTY. TO MY UNDERSTANDING IF THE ITEM IS A PART OF THE FUEL SYSTEM COMPONENTS, IT SHOULD BE COVERED FOR THE WARRANTY. THEY REFUSED TO SATISFY THE WARRANTY AND I ENDED UP NOT AUTHORIZING THE REPAIRS. NOW BECAUSE MERCEDES WILL NOT REPAIR THE COVERED PART, I HAVE TO TAKE IT TO ANOTHER REPAIR SHOP TO HAVE IT FIXED. I THINK MERCEDES SHOULD REIMBURSE ME FOR MY TIME AND PARTS AND LABOR FOR NOT SATISFYING THEIR EXTENDED WARRANTY.....UPDATED 10/15/15 *BF

NHTSA ODI #10735343

147,102 miles · Jan 12, 2015
Fuel System, Gasoline

I HAVE HAD THIS PROBLEM FOR A WHILE NOW. WHEN I FILL UP MY FUEL TANK THERE IS A DRASTIC SMELL OF GAS. I BELIEVE THIS IS A SAFETY ISSUE. I HAD TO LEAVE MY CAR OUT ON THE STREET IN FEAR MY WATER HEATER WHEN IGNITING WOULD SET OFF A EXPLOSION. I AM SURE MB KNOWS OF THIS SITUATION SINCE I HAVE SEEN NUMEROUS REMARKS AND INSTANCES O…

Read full complaint

I HAVE HAD THIS PROBLEM FOR A WHILE NOW. WHEN I FILL UP MY FUEL TANK THERE IS A DRASTIC SMELL OF GAS. I BELIEVE THIS IS A SAFETY ISSUE. I HAD TO LEAVE MY CAR OUT ON THE STREET IN FEAR MY WATER HEATER WHEN IGNITING WOULD SET OFF A EXPLOSION. I AM SURE MB KNOWS OF THIS SITUATION SINCE I HAVE SEEN NUMEROUS REMARKS AND INSTANCES ON JUST THIS SUBJECT. I WOULD HOPE THAT MB WILL ADDRESS THIS PROBLEM. I TOOK IT TO THE DEALER AND INDEED THEY SAID THAT THE FUEL SENDING UNIT HAS A CRACK ON TOP ALLOWING THE FUEL TO LEAK WHEN FILLED UP TO THE FULL MARK. THANK YOU ADVANCE IN REPORTING THIS TO MERCEDES. *TR

NHTSA ODI #10671778

99,910 miles · Aug 26, 2014
Fuel System, Gasoline

CRACK AROUND FUEL PUMP AND FUEL LINE. CONSTANT STRONG ODOR OF RAW GASOLINE IN AND AROUND THE CAR. FILLS THE GARAGE WITH GAS ODOR AND INTO HOUSE. WHILE PARKED OUTSIDE GAS CAN STILL BE SMELLED. UNSAFE WHETHER PARKED, OR BEING DRIVEN. *TR

NHTSA ODI #10628585

152,000 miles · Aug 4, 2014
Fuel System, Gasoline

FUEL LEAKS AND FUEL FUMES IN CABIN. *TR

NHTSA ODI #10618727

140,000 miles · Apr 18, 2014
Fuel System, Gasoline

I SMELL GAS INSIDE MY VEHICLE WHEN I FILL UP MY GAS TANK AND IT SMELLS REALLY STRONG IN THE CAR , I TOOK IT TO MERCEDES DEALERSHIP AND THEY SAID THAT THERE WAS IN FACT A LEAK I HAD PAY FOR THEM TO DIAGNOSIS IT AND THEY ALSO SAID IT WAS LEAKING A LITTLE INSIDE THE VEHICLE THAT THEY COULD NOT FIX IT AND THAT I HAD TO PAY TO REPLAC…

Read full complaint

I SMELL GAS INSIDE MY VEHICLE WHEN I FILL UP MY GAS TANK AND IT SMELLS REALLY STRONG IN THE CAR , I TOOK IT TO MERCEDES DEALERSHIP AND THEY SAID THAT THERE WAS IN FACT A LEAK I HAD PAY FOR THEM TO DIAGNOSIS IT AND THEY ALSO SAID IT WAS LEAKING A LITTLE INSIDE THE VEHICLE THAT THEY COULD NOT FIX IT AND THAT I HAD TO PAY TO REPLACE THE TANK AND FUEL PUMP AND SENDING UNIT . *TR

NHTSA ODI #10583429

62,000 miles · Apr 15, 2014
Fuel System, GasolineUnknown Or Other

DEAR SIR OR MADAM, I CONSISTENTLY SMELL GAS LEAK FROM MY CAR. [XXX] 'PARTS OF THIS DOCUMENT HAVE BEEN REDACTED TO PROTECT PERSONALLY IDENTIFIABLE INFORMATION PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6).' *TT

NHTSA ODI #10582912

82,171 miles · Feb 15, 2014
Fuel System, Gasoline

REFERENCE NHTSA ACTION NUMBER: PE12001 AFTER FILLING VEHICLE GAS TANK, VEHICLE HAS A VERY STRONG FUEL ODOR INSIDE AND OUTSIDE THE VEHICLE. FUEL IS LEAKING AROUND SENDING UNIT AT GAS TANK, AND AFTER SPEAKING WITH OTHER VEHICLE OWNERS, THIS IS A COMMON PROBLEM. DUE TO THE LEAK, VEHICLE CANNOT BE KEPT IN THE GARAGE UNTIL FUEL LEVE…

Read full complaint

REFERENCE NHTSA ACTION NUMBER: PE12001 AFTER FILLING VEHICLE GAS TANK, VEHICLE HAS A VERY STRONG FUEL ODOR INSIDE AND OUTSIDE THE VEHICLE. FUEL IS LEAKING AROUND SENDING UNIT AT GAS TANK, AND AFTER SPEAKING WITH OTHER VEHICLE OWNERS, THIS IS A COMMON PROBLEM. DUE TO THE LEAK, VEHICLE CANNOT BE KEPT IN THE GARAGE UNTIL FUEL LEVEL REACHES 3/4 TANK. ALSO, THE SMELL IS SO BAD INSIDE THE VEHICLE AFTER FILL UP, IT IS DANGEROUS TO DRIVE. *TR

NHTSA ODI #10564460

104,700 miles · Jan 1, 2014
Fuel System, Gasoline

STRONG SMELL OF GASOLINE IN CABIN OF VEHICLE AND OUTSIDE ON DRIVERS SIDE AFTER FILLING UP THE NIGHT PRIOR. THE CAR WAS NOT "TOPPED OFF". ONLINE SEARCH FOR CAUSE OF THIS PROBLEM FOUND THIS IS COMMON AMONG W211 MERCEDES VEHICLES. THIS CAR IS NEW TO ME, THIS IS THE FIRST TIME I FUELED THE CAR. *TR

NHTSA ODI #10558057

90,000 miles · Dec 17, 2013
Fuel System, Gasoline

I OWN A 2003 MERCEDES E500. 100, 000 MILES AND I CAN SMELL HEAVY GAS FUMES FROM BOTH INTERIOR AND EXTERIOR OF MY CAR.THE CARS REARLEFT DRIVERSIDE HAS EXTREME GAS VAPOR FUMES COMING FROM FUELTANK AREA BEHIND RIGHT REAR WHEEL. SINCE I'VE NOTICED THE HEAVY FUEL ODORS, THE CAR HAS BEEN PARKED BECAUSE ITS UNSAFE TRANSPORTATION FOR MY…

Read full complaint

I OWN A 2003 MERCEDES E500. 100, 000 MILES AND I CAN SMELL HEAVY GAS FUMES FROM BOTH INTERIOR AND EXTERIOR OF MY CAR.THE CARS REARLEFT DRIVERSIDE HAS EXTREME GAS VAPOR FUMES COMING FROM FUELTANK AREA BEHIND RIGHT REAR WHEEL. SINCE I'VE NOTICED THE HEAVY FUEL ODORS, THE CAR HAS BEEN PARKED BECAUSE ITS UNSAFE TRANSPORTATION FOR MY WIFE AND DAUGHTERS. INHALING THE FUEL SMELL IS DANGEROUS ENOUGH. I'M INTERESTED IN KNOWING IF FILING A COMPLAINT OR CLAIM IS POSSIBLE AND I ALSO WANT TO KNOW IF THERE ARE ANY RECALLS OR CAN THE MERCEDES DEALER HELP WITH OPTIONS TO FIX MY CAR? ANY POSITIVE ANSWERS WILL BE APPRECIATED. THANK YOU *TR

NHTSA ODI #10556295

Mileage unknown · Nov 12, 2013
Fuel System, Gasoline

WE PURCHASED THIS VEHICLE IN MAY OF 2012. WE HAD TO HAVE THE CANISTER REPLACED IN THE VEHICLE ($1000), AND AFTER THAT REPAIR, WE WERE TOLD THAT THE FUEL VAPOR VALVE NEEDED TO BE REPLACED. WE BROUGHT IT INTO MERCEDES WHEN THEY REPLACED THE SBC BRAKE SYSTEM DUE TO A RECALL AND WERE TOLD THAT THE FUEL VAPOR VALVE WASN'T AFFECTING A…

Read full complaint

WE PURCHASED THIS VEHICLE IN MAY OF 2012. WE HAD TO HAVE THE CANISTER REPLACED IN THE VEHICLE ($1000), AND AFTER THAT REPAIR, WE WERE TOLD THAT THE FUEL VAPOR VALVE NEEDED TO BE REPLACED. WE BROUGHT IT INTO MERCEDES WHEN THEY REPLACED THE SBC BRAKE SYSTEM DUE TO A RECALL AND WERE TOLD THAT THE FUEL VAPOR VALVE WASN'T AFFECTING ANYTHING, SO WE DIDN'T NEED TO REPAIR IT. WE BROUGHT THE VEHICLE FOR A SMOG CHECK SO WE COULD RENEW OUR REGISTRATION IN JULY OF 2013 AND IT FAILED DUE TO THE CHECK ENGINE LIGHT BEING ON. THE ENGINE LIGHT IS ON DUE TO THE FUEL VAPOR VALVE BEING OPEN. WE CANNOT GET THE ENGINE LIGHT TO GO OFF, SO WE CANNOT PASS A SMOG CHECK. WE ALSO CANNOT FILL IT UP ALL THE WAY BECAUSE STRONG FUMES FILL UP THE GARAGE AND GAS LEAKS OUT. WE WERE LOOKING UP AN ISSUE WITH THE BATTERY ON GOOGLE ON 11/10/2013 AND COME ACROSS A CLASS ACTION LAWSUIT WITH MERCEDES BENZ ABOUT THIS ISSUE. WE WERE NEVER INFORMED ABOUT THE PROBLEM THAT THEY WERE HAVING WITH THIS CAR. WE WOULD LIKE FOR THEM TO REPAIR OUR VEHICLE SO WE WILL FEEL SAFE DRIVING IT. *TR

NHTSA ODI #10551973

Official recalls

3

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA13003 · Fuel Leakage From The Fuel Tank

Opened Mar 15, 2013 · Closed Dec 19, 2014

Status: closed (inferred from source dates) · Fuel System, Gasoline; Fuel System, Gasoline:delivery; Fuel System, Gasoline:delivery:fuel Pump; Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings; Fuel System, Gasoline:storage; Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Additional source detail variants (6)

Fuel System, Gasoline:delivery:fuel Pump

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery:hoses, Lines/piping, And Fittings

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:delivery

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un

Fuel System, Gasoline:storage:tank Assembly

The Office of Defects Investigation (ODI) opened this investigation on January 23, 2012 as PE12-001 based on 20 consumer reports in model year (MY) 2003-2006 E55 AMG vehicles.Based on new reports in other E-Class vehicles, ODI upgraded the investigation to Engineering Analysis (EA) 13-003 on March 15, 2013, and expanded the scope to all E-Class vehicles through MY 2008.The complainants alleged a strong odor of gasoline fuel both inside and outside of their vehicle, particularly after refilling the fuel tank.Many of the complainants noted that the odor subsided or went away after driving some distance thereby lowering the fuel level in the tank.Other owners reported they would only fill the tank to about three quarters full to avoid the odor altogether.Some complainants alleged fuel leaked from the fuel filter/sender, located on the top of the fuel tank on the driver's side, and collected on top of the tank.There were also allegations that the fuel leaks were associated with an Emissions Recall Campaign (No. 2008020001) conducted by Mercedes-Benz USA, LLC (Mercedes) in 2008 on MY 2003-2006 E-Class and CLS-Class AMG models.The issue in the recall involved small cracks in the pressurized outlet fitting of the fuel filter/sender.AMG vehicles are high performance models that operate at higher fuel pressure and use a different fuel filter/sender and fuel pump than non-AMG models.Information on Recall No. 2008020001 is available from the U.S. Environmental Protection Agency (EPA) website at www.EPA.gov.ODI's investigation found various leak sources that are unrelated to the outlet fitting cited in the EPA recall campaign.Through interviews with complainants, field inspections of complaint vehicles, and the collection and laboratory analysis of failed parts, three identifiable leak sources were found.The component parts and areas of the leaks involve the On-Board Diagnostic fuel tank pressure sensor (located on top of the fuel filter/sender), the outlet of the centrally mounted fuel tank fuel filling limiter valve, and the top of the fuel pump. These areas of leakage are located at the top of the fuel tank in unpressurized parts of the fuel system. When the tank is full, fuel can slowly weep/seep from micro-cracks in these components and may collect in cavities on top of the filter/sender, pump, or tank.Contrary to complainant's allegations that fuel entered the inside of their vehicle under the rear seat bench, neither ODI nor Mercedes found a plausible way for this to occur.The fuel tank is located outside of the passenger compartment, attached to the underside of the vehicle.The service access ports for the fuel filter/sender (driver's side) and fuel pump (passenger's side) are located under the rear seat bench, covered by a steel plate, sealed and bolted to the vehicle floor.When technicians service the fuel filter/sender, which has a regularly scheduled 60,000 mile service interval, and/or the fuel pump, the work is performed from inside the vehicle by working through the access ports.By letter dated September 4, 2014, Mercedes has notified the agency that it will extend the original warranty coverage to 15 years and unlimited mileage on Covered Fuel Tank Components in E-Class vehicles in MY 2003-2009 and CLS-Class vehicles in MY 2006-2011.The covered fuel tank components for the warranty extension include the fuel tank, fuel filter/sender, fuel pump, and all related gaskets/seals and retention rings.ODI is closing this investigation based on the manufacturer's extend warranty of the affected fuel system components and in consideration that the nature of the leaks does not appear to present an un