← New search

2007 Mercedes Benz C230

Owner reports · Recalls · Investigations

More warning signs than most C230 years

Owner complaints for the 2007 Mercedes Benz C230 are substantially higher than the model-year median of 39.

About this comparison →

When problems were reported

Mileage at the reported incident

149 reports with mileage · 63 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel/propulsion System. Review the 55 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Air Bags. Review the 52 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 51 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports4 fire reports9 injury reports

Air Bags complaints

52 reports
Clear category filter
Mileage unknown · Dec 26, 2017
Air BagsElectrical System

I RECEIVED A RECALL ON THE AIRBAG AND ELECTRICAL SYSTEM

NHTSA ODI #11056573

Mileage unknown · Dec 20, 2017
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS). THE PARTS DO TO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT CONTACTED A LOCAL D…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS). THE PARTS DO TO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE CONTACT HAD NOT CONTACTED A LOCAL DEALER OR THE MANUFACTURER FOR PART AVAILABILITY. THE CONTACT RECEIVED A NOTICE FROM TK HOLDINGS ABOUT TAKATA FILING FOR BANKRUPTCY. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #11055788

Mileage unknown · Dec 4, 2017
Air Bags

TAKATA RECALL I HAVE 2 VEHICLES AFFECTED AND THERE IS NO PLANNED REMEDY. I HAVENT RECEIVED ANY UPDATES. THIS IS GOING ON 2 YEARS. IT WILL BE TOO LATE WHEN SOMEONE GETS HARMED OR KILLED. 2014 DODGE AVENGER AND THIS MERCEDES.

NHTSA ODI #11052314

Mileage unknown · Nov 29, 2017
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF O…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF OKLAHOMA CITY, 1225 N BROADWAY AVE, OKLAHOMA CITY, OK 73103) WAS CONTACTED AND CONFIRMED THAT THE PARTS WERE NOT AVAILABLE FOR THE RECALL REMEDY. THE MANUFACTURER WAS NOT CONTACTED. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #11051342

Mileage unknown · Nov 29, 2017
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS). THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF ONTARIO, 3…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS). THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF ONTARIO, 3787 E GUASTI RD, ONTARIO, CA 91761) WAS CONTACTED AND CONFIRMED THAT THE PARTS WERE NOT AVAILABLE FOR THE RECALL REMEDY. THE MANUFACTURER WAS NOT CONTACTED. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE.

NHTSA ODI #11051271

Mileage unknown · Nov 25, 2017
Air Bags

TAKATA RECALL I HAVE NOTIFICATION FROM MERCEDES AND NHTSA NUMEROUS TIMES THAT THE RECALL PART IS READY AND THAT I SHOULD MAKE AN APPOINTMENT. HOWEVER, EVERY TIME I MAKE APPOINTMENT, THE DEALER (MERCEDES-BENZ OF PLANO,TEXAS) THEY HAVE NOTHING AVAILABLE FOR MY BOTH OF MY CARS. NOT ONLY THAT, THEY CANCEL APPOINTMENTS IMMEDIATELY A…

Read full complaint

TAKATA RECALL I HAVE NOTIFICATION FROM MERCEDES AND NHTSA NUMEROUS TIMES THAT THE RECALL PART IS READY AND THAT I SHOULD MAKE AN APPOINTMENT. HOWEVER, EVERY TIME I MAKE APPOINTMENT, THE DEALER (MERCEDES-BENZ OF PLANO,TEXAS) THEY HAVE NOTHING AVAILABLE FOR MY BOTH OF MY CARS. NOT ONLY THAT, THEY CANCEL APPOINTMENTS IMMEDIATELY AFTER IT WAS MADE AND WAS NOT COURTEOUS IN THEIR RESPONSE ON ALL OCCASIONS.

NHTSA ODI #11048406

Mileage unknown · Nov 15, 2017
Air Bags

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF S…

Read full complaint

TL* TAKATA RECALL. THE CONTACT OWNS A 2007 MERCEDES-BENZ C230. THE CONTACT RECEIVED NOTIFICATION OF NHTSA CAMPAIGN NUMBER: 16V081000 (AIR BAGS); HOWEVER, THE PARTS TO DO THE REPAIR WERE UNAVAILABLE. THE CONTACT STATED THAT THE MANUFACTURER EXCEEDED A REASONABLE AMOUNT OF TIME FOR THE RECALL REPAIR. THE DEALER (MERCEDES-BENZ OF ST. CLAIR SHORES, 20200 E 9 MILE RD, ST CLAIR SHORES, MI 48080) WAS CONTACTED AND CONFIRMED THAT THE PARTS WERE NOT AVAILABLE FOR THE RECALL REMEDY. THE MANUFACTURER WAS NOT CONTACTED. THE CONTACT HAD NOT EXPERIENCED A FAILURE. VIN TOOL CONFIRMS PARTS NOT AVAILABLE. *TT UPDATED 8/20/18*JB

NHTSA ODI #11046277

Mileage unknown · Nov 13, 2017
Air Bags

TAKATA RECALL - NO REMEDY AVAILABLE AS OF 11/13/17.

NHTSA ODI #11045702

Mileage unknown · Nov 11, 2017
Air Bags

TAKATA RECALL. I HAVE CALLED MBZ OF ANAHEIM ON NOV 11 2017 AND THEY ANSWER THAT NO PART IS AVAILABLE FOR SCHEDULING THE AIRBAG REPLACEMENT. PLEASE TELL ME WHAT I SHOULD DO. THANK YOU

NHTSA ODI #11045350

Mileage unknown · Nov 10, 2017
Air Bags

TAKATA INFLATORS - RECALL WAS FEB 2016 --- I DRIVE THIS CAR EVERY DAY AND IT HAS BEEN 18 MONTHS SINCE THE RECALL. I WANT THE AIR BAGS REPLACED IMMEDIATELY - IT HAS BEEN LPONG ENOUGH TO RESOLVE THIS ISSUE.

NHTSA ODI #11045121

Official recalls

5

24V874000 · Visibility:sun/moon Roof Assembly

Nov 19, 2024

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please see the recall report for a complete list of models and model years. The glass sunroof panel may not be properly secured and can detach.

Consequence & remedy

Consequence: A detached sunroof panel can become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary, free of charge. Owner notification letters were mailed January 10, 2025. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of previous NHTSA recall number 22V-954. MBUSA's number for this recall is 2024120001/2/3.

22V954000 · Visibility:sun/moon Roof Assembly

Dec 23, 2022

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2001-2011 C-Class, CLK, E-Class, and CLS vehicles. Please refer to MBUSA's recall report for specific vehicle model details. The glass sunroof panel may not be properly secured and may detach.

Consequence & remedy

Consequence: A detached sunroof panel may become a road hazard, increasing the risk of a crash.

Remedy: Dealers will inspect and replace the sunroof panel as necessary free of charge. Owner notification letters were mailed February 3, 2023. Owners may contact MBUSA customer service at 1-800-367-6372. This recall expands NHTSA recall number 19V-918. MBUSA's numbers for this recall are 2023010004, 2023010005, and 2023010006.

21V196000 · Visibility:sun/moon Roof Assembly

Mar 19, 2021

Mercedes-Benz USA, LLC (MBUSA) is recalling certain 2006-2007 C350, C230, C280, CLK350, E320CDI, E350 Wagon, E350, 2006 C55 AMG, CLK500, CLS500, CLS55 AMG, E500 Wagon, E500, E55 AMG, 2007 CLK550, CLS550, CLS63 AMG, E550, E63 AMG, and E63 Wagon AMG vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly causing the glass panel to detach from the vehicle.

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. Owner letters were mailed May 7, 2021. Owners may contact MBUSA customer service at 1-800-367-6372. This recall is an expansion of recall number 19V-918. MBUSA's number for this recall is 2021040012.

19V918000 · Visibility:sun/moon Roof Assembly

Dec 20, 2019

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain 2001-2011 vehicles. The bonding between the glass panel and the sliding roof frame may deteriorate, possibly resulting in the glass panel detaching from the vehicle. For a full list of the affected models visit: https://static.nhtsa.gov/odi/rcl/2019/RMISC-19V918-4126.pdf

Consequence & remedy

Consequence: A detached glass panel can separate from the vehicle and become a road hazard, increasing the risk of a crash.

Remedy: MBUSA will notify owners, and dealers will inspect the glass panel bonding and replace the sliding roof, as necessary, free of charge. The recall began July 10, 2020. Owners may contact MBUSA customer service at 1-800-367-6372. MBUSA's number for this recall is 2020040011.

16V081000 · Air Bags:frontal:driver Side:inflator Module

Feb 11, 2016

Mercedes-Benz USA, LLC. (MBUSA) is recalling certain model year 2009-2010 ML320 BlueTec 4Matic, GL320 BlueTec 4Matic and R320 CDI 4Matic, 2011 E350 Cabriolet and E550 Cabriolet, 2009-2011 ML350, ML350 4Matic, ML550 4Matic, ML63 AMG, and C63 AMG, 2010-2011 ML450 4Matic Hybrid, E350 Coupe, E350 4Matic, E550 Coupe, E550 4Matic, and E63 AMG, 2011-2012 GL350 BlueTec 4Matic and R350 BlueTec 4Matic, 2009-2012 GL450 4Matic, GL550 4Matic and R350 4Matic, 2007-2008 SLK280, SLK350, and SLK55 AMG, 2011-2014 SLS AMG Coupe, 2012 SLS AMG Cabriolet, 2013-2014 SLS AMG GT and SLS AMG GT Cabriolet, 2005 C230 Kompressor and C320, 2006-2007 C230, 2006-2011 C350, 2008-2011 C300 and C300 4Matic, 2010-2012 GLK350 and GLK350 4Matic and 2007-2008 Chrysler Crossfire vehicles. Upon deployment of the driver's frontal air bag, excessive internal pressure may cause the inflator to rupture.

Consequence & remedy

Consequence: In the event of a crash necessitating deployment of the driver's frontal air bag, the inflator could rupture with metal fragments striking the driver or other occupants resulting in serious injury or death.

Remedy: MBUSA will their notify owners, and Fiat Chrysler will notify the affected Chrysler owners. Dealers for the respective brands will replace the driver's frontal air bag module, free of charge. This recall began November 2016. Mercedes-Benz owners may contact MBUSA customer service at 1-800-367-6372 and Chrysler owners may contact Fiat Chrysler customer service at 1-800-853-1403.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

EA21002 · Desiccated Air Bag Inflator Rupture

Opened Sep 17, 2021 · No close date supplied

Status: open (inferred from source dates) · Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Additional source detail variants (2)

Air Bags:frontal:driver Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.

Air Bags:frontal:passenger Side:inflator Module

From 2000 through 2017, Takata produced millions of air bag inflators using two types of phase-stabilized ammonium nitrate ("PSAN") propellant -- propellant 2004 and propellant 2004L. After prolonged exposure to high temperature cycles and humidity, inflators using propellant 2004 can degrade, causing the propellant to burn too quickly when ignited. The rapid burning can cause the inflator to rupture during deployment, potentially causing serious or even fatal injury to vehicle occupants. See 2016 Blomquist Report at www.nhtsa.gov/sites/nhtsa.gov/files/documents/expert_report-hrblomquist.pdf.Consequently, all frontal inflators using propellant 2004 that do not contain a "desiccant" (a substance that traps and holds moisture) in US vehicles are under recall. These "non-desiccated" inflators either have been or are required to be replaced.In some cases, the remedy part for these recalled inflators was, or will be, an inflator using either propellant 2004 or 2004L that does contain a desiccant. None of these "desiccated" remedy parts (which were installed in older model year vehicles) are currently under recall for a degradation concern. Certain subsets of desiccated PSAN inflators using propellant 2004 for use as original equipment, however, have been recalled for a degradation concern. All Takata inflators produced with propellant 2004L contain desiccant, and none of these desiccated inflators using propellant 2004L are under recall for a degradation concern. There have been no reported field ruptures in any non-recalled desiccated PSAN inflators.It is understood that desiccants fully saturate at some threshold, at which point any additional moisture will not be captured. This means the degradation process observed in non-desiccated inflators using propellant 2004 may also occur in non-recalled desiccated inflators using propellant 2004, assuming additional moisture enters the inflator and high temperature cycling occurs. Based on available information, desiccant saturation can occur within the first five years in the worst environments, and the time required for full saturation is affected by multiple factors. While no present safety risk has been identified, further work is needed to evaluate the future risk of non-recalled desiccated inflators using propellant 2004.Three entities -- Takata (now known as TK Global), the Independent Testing Coalition, and Exponent -- have been studying the long-term behavior of Takata desiccated PSAN inflators using propellant 2004L (as well as 2004) in the presence of moisture and temperature cycling. The research efforts, which include development of predictive modeling techniques and field sample analysis, are ongoing. To date, none of the researchers have identified field evidence showing that propellant 2004L is undergoing a degradation process that leads to aggressive deployment and potential rupture. However, the time in service of such inflators remains short compared to that of the inflators using propellant 2004. Further study is needed to assess the long-term safety of desiccated inflators using propellant 2004L.The Office of Defects Investigation is opening this investigation to examine whether a safety defect related to propellant degradation exists in non-recalled desiccated PSAN frontal inflators manufactured by Takata. This investigation will require extensive information on Takata production processes and surveys of inflators in the field. Lists of recall actions that may have used desiccated PSAN inflators as remedy parts, as well as the makes and models originally manufactured with them, is available with the downloadable version of this document (see nhtsa.gov/recalls?nhtsaId=EA21002 -- note this information is subject to change/revision as the investigation proceeds). This investigation does not supersede EA15-001, which remains open.