← New search

2005 Ford Freestar

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

When problems were reported

Mileage at the reported incident

804 reports with mileage · 82 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Power Train. Review the 677 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 85 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 53 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

8 crash reports2 fire reports14 injury reports

Power Train complaints

677 reports
Clear category filter
40,034 miles · Jul 15, 2008
Power Train

2005 FORD FREESTAR AUTO TRANSMISSION WENT OUT WHILE BACKING OUT OF DRIVEWAY. FLUID LEVEL OK, FLUID APPEARS CLEAN, SMELLS NEW. *TR

NHTSA ODI #10234456

40,034 miles · Jul 15, 2008
Power Train

TRANSMISSION WENT OUT WHILE BACKING OUT OF DRIVEWAY . MAJOR SLIPPAGE. SEEM STUCK IN NEUTRAL. *TR

NHTSA ODI #10234455

41,000 miles · Jul 14, 2008
Power Train

WE HAVE NOT HAD ANY PRIOR PROBLEMS WITH OUR MINIVAN. WE WERE DRIVING WITH OUR 2 SMALL CHILDREN ON A MAJOR HIGHWAY DOING AT LEAST 60 MPH WHEN OUR VAN WOULD NOT GO WHEN MY HUSBAND PUT HIS FOOT ON THE GAS. HE WAS ABLE TO GET THE VAN TO THE SIDE OF THE ROAD WITHOUT ANY INCIDENT. THE ENGINE WAS RUNNING (AIR CONDITIONING, RADIO, DV…

Read full complaint

WE HAVE NOT HAD ANY PRIOR PROBLEMS WITH OUR MINIVAN. WE WERE DRIVING WITH OUR 2 SMALL CHILDREN ON A MAJOR HIGHWAY DOING AT LEAST 60 MPH WHEN OUR VAN WOULD NOT GO WHEN MY HUSBAND PUT HIS FOOT ON THE GAS. HE WAS ABLE TO GET THE VAN TO THE SIDE OF THE ROAD WITHOUT ANY INCIDENT. THE ENGINE WAS RUNNING (AIR CONDITIONING, RADIO, DVD PLAYER ALL WORKING)BUT WHEN HE PUT HIS FOOT ON THE GAS THE VEHICLE DID NOT MOVE. WE NOW HAVE TO HAVE A REBUILT TRANSMISSION PUT IN THE VEHICLE. *TR

NHTSA ODI #10234285

36,400 miles · Jul 10, 2008
Power Train

AFTER DRIVING UP TO THE UPPER PENINSULA, MY FIANCE WAS DRIVING OUR 2005 FORD FREESTAR LIMITED BACK TO HER PARENT'S HOUSE. SHE DRIVING UP THE HILL ON THE HIGHWAY WHEN SUDDENLY, THE ENGINE'S RPMS INCREASED DRAMATICALLY AND THE VEHICLE BEGAN TO ROLE DOWN THE HILL. SHE WAS NOT TOWING ANYTHING WITH THE VEHICLE. AFTER THE VEHICLE C…

Read full complaint

AFTER DRIVING UP TO THE UPPER PENINSULA, MY FIANCE WAS DRIVING OUR 2005 FORD FREESTAR LIMITED BACK TO HER PARENT'S HOUSE. SHE DRIVING UP THE HILL ON THE HIGHWAY WHEN SUDDENLY, THE ENGINE'S RPMS INCREASED DRAMATICALLY AND THE VEHICLE BEGAN TO ROLE DOWN THE HILL. SHE WAS NOT TOWING ANYTHING WITH THE VEHICLE. AFTER THE VEHICLE CAME TO REST, SHE WAS NOT ABLE TO PUT THE VEHICLE INTO GEAR AND DRIVE. THE VEHICLE WAS FIRST TOWED TO RAHILLY FORD DEALERSHIP IN NEWBERRY, MI. THEY WERE UNABLE TO DIAGNOSE THE PROBLEM BECAUSE THEY DO NOT HAVE A TRANSMISSION TECHNICIAN, SO THEY OUTSOURCED THE JOB TO A COMPANY IN CANADA CALLED MR. TRANSMISSION. AFTER MR. TRANSMISSION REMOVED THE TRANSMISSION AND DISASSEMBLED IT, THEY DISCOVERED THE FRONT PUMP AND TORQUE CONVERTER FAILED. MR. TRANSMISSION ORDERED A NEW TORQUE CONVERTER, PUMP, AND SEALS TO REPAIR THE TRANSMISSION. TOTAL BILL COMES OUT TO BE $2600 DOLLARS. SO FAR, FORD HAS BEEN NO HELP IN THE REPAIR OF THE VEHICLE. *TR

NHTSA ODI #10233746

65,000 miles · Jun 15, 2008
Power Train

WE WERE DRIVING THROUGH A NEIGHBORHOOD WHEN WE TURNED AROUND IN SOMEONE'S DRIVEWAY AFTER PUTTING IT BACK IN DRIVE THE VAN LOST ALL TRANSMISSION POWER. THE VAN WOULD NOT GO IN FORWARD OR REVERSE IN ANY GEAR. *TR

NHTSA ODI #10231056

38,800 miles · Jun 9, 2008
Power Train

DRIVING DOWN THE STREET WITH MY FAMILY IN THE VEHICLE, THE TRANSMISSION JUST STOPPED WORKING, NO WARNING SIGNS WHATSOEVER, JUST LOST LOST POWER IN THE MIDDLE OF THE STREET. THE STREET HAD A SLIGHT INCLINE TO IT, SO WE WERE ABLE TO COAST TO THE SIDE OF THE ROAD AND THEN PARKED IT UP ON THE SIDEWALK, TO GET THE VEHICLE OUT OF THE …

Read full complaint

DRIVING DOWN THE STREET WITH MY FAMILY IN THE VEHICLE, THE TRANSMISSION JUST STOPPED WORKING, NO WARNING SIGNS WHATSOEVER, JUST LOST LOST POWER IN THE MIDDLE OF THE STREET. THE STREET HAD A SLIGHT INCLINE TO IT, SO WE WERE ABLE TO COAST TO THE SIDE OF THE ROAD AND THEN PARKED IT UP ON THE SIDEWALK, TO GET THE VEHICLE OUT OF THE MIDDLE OF THE TWO LANE STREET WE WERE DRIVING ON. THE REPAIRS HAVE NOT BEEN MADE AS OF YET, WE ARE BEING TOLD THE TRANSMISSION IS DEFECTIVE. *TR

NHTSA ODI #10230338

65,800 miles · May 26, 2008
Power Train

I DRIVING HOME FORM WORK, WHEN ALL OF A SUDDEN THE RPMS WHEN UP AND THE CAR SEEMED TO HAVE SLIPPED INTO NEUTRAL. I TRIED TO ACCELERATE BUT THE ENGINE JUST REVVED. I COASTED INTO A GAS STATION. NOW I HAVE THOUSANDS OF DOLLARS OF REPAIRS THAT I CANNOT AFFORD. I HAVE BEEN RESEARCHING THIS AND APPARENTLY THIS IS NOT AN ISOLATED I…

Read full complaint

I DRIVING HOME FORM WORK, WHEN ALL OF A SUDDEN THE RPMS WHEN UP AND THE CAR SEEMED TO HAVE SLIPPED INTO NEUTRAL. I TRIED TO ACCELERATE BUT THE ENGINE JUST REVVED. I COASTED INTO A GAS STATION. NOW I HAVE THOUSANDS OF DOLLARS OF REPAIRS THAT I CANNOT AFFORD. I HAVE BEEN RESEARCHING THIS AND APPARENTLY THIS IS NOT AN ISOLATED INCIDENT WITH THIS MAKE AND MODEL. *TR

NHTSA ODI #10228902

72,000 miles · May 25, 2008
Power Train

WITHOUT WARNING THE TRANSMISSION FAILED. I WAS IM THE MIDDLE OF THE STREET WHEN THIS HAPPENED, LUCKY IT WASN'T A BUSY STREET. *TR

NHTSA ODI #10228853

57,000 miles · May 23, 2008
Power Train

AUTOMATIC TRANSMISSION FAILED AND NEEDED A NEW PUMP SHAFT, TORQUE CONVERTER AND AN OVERHAUL OF THE MANUAL CONTROL VALVE. *TR

NHTSA ODI #10228752

55,000 miles · Apr 23, 2008
Power Train

I HAVE A 2005 FORD FREESTAR THAT NEEDS A TRANSMISSION. I WAS DRIVING TO WORK TODAY AND OUT OF NO WHERE MY VAN STOPPED DRIVING. THE ENGINE WAS ON BUT THE VAN WOULDN'T MOVE. I WAS JUST ABOUT TO GET ONTO INTERSTATE 95 (ABOUT 100 FEET FROM ON RAMP) I COULD HAVE BEEN KILLED MY CHILDREN COULD HAVE BEEN KILLED. MY CAR WOULDN'T MOVE AT …

Read full complaint

I HAVE A 2005 FORD FREESTAR THAT NEEDS A TRANSMISSION. I WAS DRIVING TO WORK TODAY AND OUT OF NO WHERE MY VAN STOPPED DRIVING. THE ENGINE WAS ON BUT THE VAN WOULDN'T MOVE. I WAS JUST ABOUT TO GET ONTO INTERSTATE 95 (ABOUT 100 FEET FROM ON RAMP) I COULD HAVE BEEN KILLED MY CHILDREN COULD HAVE BEEN KILLED. MY CAR WOULDN'T MOVE AT ALL!!! I WAS SCARED TO DEATH. I HAVE READ MANY COMPLAINTS TODAY ABOUT THE TRANSMISSION PROBLEM WITH FORD FREESTARS. I CAN'T BELIEVE THAT THERE HAS BEEN NO RECALL. I WILL COST ME $3,000 DOLLARS TO HAVE THIS FIXED. I HAVE 4 CHILDREN, WHERE DO I GET THIS MONEY FROM? I HAVE MY VAN AT A GARAGE THAT WE GO TO FOR REGULAR MAINTENANCE. THEY ARE TELLING ME THERE IS NO WARRANTY ON THIS VAN. HOW DOES THIS VAN JUST UP AND DIE WHEN IT IS 3 YEARS OLD WITH 55,000 MILE ON IT AND FORD IS NOT RESPONSIBLE FOR ANYTHING? *TR

NHTSA ODI #10225512

Official recalls

3

13V081000 · Seats

Mar 7, 2013

Ford is recalling certain model year 2004-2007 Freestar and Mercury Monterey vehicles manufactured from March 24, 2003, through November 7, 2006, equipped with a third row seat and originally sold in, or currently registered in, Connecticut, Delaware, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin and the District of Columbia. The third row stowable seat can experience corrosion and structural degradation at the seat anchor mechanism mounted to the rear wheel wells. As a result of the corrosion, the third row seat may not fully latch into its seating position.

Consequence & remedy

Consequence: In the event that the vehicle is crashed into from the rear, an unlatched seat may increase the risk of personal injury.

Remedy: Ford will notify owners, and dealers will install new third row seat latch striker mounting brackets, free of charge. The recall began on March 28, 2013. Owners may contact Ford Motor Company Customer Relationship Center at 1-866-436-7332.

12V006000 · Power Train:automatic Transmission; Power Train:automatic Transmission:torque Converter

Jan 9, 2012

FORD IS RECALLING CERTAIN MODEL YEAR 2004 AND 2005 FORD FREESTAR AND MERCURY MONTEREY VEHICLES. THE TORQUE CONVERTER OUTPUT SHAFT MAY FAIL.

Consequence & remedy

Consequence: THIS CONDITION RESULTS IN A SUDDEN LOSS OF MOTIVE POWER WITH NO WARNING, INCREASING THE RISK OF A CRASH.

Remedy: FORD WILL NOTIFY OWNERS, AND DEALERS WILL REPLACE THE TORQUE CONVERTER FREE OF CHARGE. THE SAFETY RECALL BEGAN ON AUGUST 9, 2012. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

Additional source detail variants (2)

Power Train:automatic Transmission:torque Converter

FORD IS RECALLING CERTAIN MODEL YEAR 2004 AND 2005 FORD FREESTAR AND MERCURY MONTEREY VEHICLES. THE TORQUE CONVERTER OUTPUT SHAFT MAY FAIL.

Consequence: THIS CONDITION RESULTS IN A SUDDEN LOSS OF MOTIVE POWER WITH NO WARNING, INCREASING THE RISK OF A CRASH.

Remedy: FORD WILL NOTIFY OWNERS, AND DEALERS WILL REPLACE THE TORQUE CONVERTER FREE OF CHARGE. THE SAFETY RECALL BEGAN ON AUGUST 9, 2012. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

Power Train:automatic Transmission

FORD IS RECALLING CERTAIN MODEL YEAR 2004 AND 2005 FORD FREESTAR AND MERCURY MONTEREY VEHICLES. THE TORQUE CONVERTER OUTPUT SHAFT MAY FAIL.

Consequence: THIS CONDITION RESULTS IN A SUDDEN LOSS OF MOTIVE POWER WITH NO WARNING, INCREASING THE RISK OF A CRASH.

Remedy: FORD WILL NOTIFY OWNERS, AND DEALERS WILL REPLACE THE TORQUE CONVERTER FREE OF CHARGE. THE SAFETY RECALL BEGAN ON AUGUST 9, 2012. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

06V069000 · Structure:body:hatchback/liftgate

Mar 9, 2006

ON CERTAIN VANS EQUIPPED WITH THE POWER LIFTGATE OPTION, THE POWER LIFTGATE MOTOR AUTOMATICALLY DISENGAGES AFTER THE LIFTGATE IS POWERED OPEN.

Consequence & remedy

Consequence: IN THE EVENT OF A LIFTGATE STRUT MALFUNCTION, THE LIFTGATE CAN FALL FREELY WITH NO PRIOR WARNING. ANYONE STANDING BENEATH THE LIFTGATE MAY BE INJURED IF THE LIFTGATE FALLS.

Remedy: DEALERS WILL REPROGRAM THE POWER LIFTGATE MODULE TO REDUCE THE LIKELIHOOD THAT THE LIFTGATE COULD FALL FREE OF CHARGE. THE RECALL BEGAN ON MARCH 15, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

6

EQ12010 · Stabilus Rear Liftgate Struts Failing

Opened Sep 28, 2012 · Closed Dec 31, 2012

Status: closed (inferred from source dates) · Structure:body:hatchback/liftgate:support Device/strut

Please see the attached closing resume summary.It has been attached to this document as a PDF.

EA12003 · Corrosion Of Third-Row Seat Attachment

Opened Apr 23, 2012 · Closed May 2, 2013

Status: closed (inferred from source dates) · Seats; Seats:mid/rear Assembly; Structure; Structure:body

Ford is conducting a safety recall to repair the third-row seat's latch mechanisms in approximately 196,667 model year (MY) 2004 through 2007 Ford Freestar and Mercury Monterey vehicles (see NHTSA recall 13V-081 for more details).The recall covers vehicles originally sold, or currently registered, in the salt belt states or high corrosion areas of the United States: Connecticut, Delaware, the District of Columbia, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, and Wisconsin.Approximately 100,000 remaining MY 2004-2007 Freestar and Monterey vehicles--those vehicles that were not originally sold, or are not currently registered, in salt belt states--are not included in the recall action. Although these vehicles are the same as the ones described above, they experience significantly lower failure rates because of reduced road salt exposure.ODI is currently aware of only one complaint on vehicle outside of the recall scope.ODI will monitor complaints and take further action if warranted by the circumstances.For owners of vehicles that are outside of the recall scope but exhibit the defect condition, owners (and affected Ford dealers) can contact Ford to request the recall repair.This Engineering Analysis is closed.See attached report and associated recall file for additional information.The ODI reports cited above can be reviewed online at http://www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following identification numbers: 10399896, 10410491, 10420028, 10424850, 10433928, 10436592, 10438529, 10440616, 10441489, 10441641, 10442809, 10446564, 10450295, 10450559, 10450587, 10452933, 10453826, 10454977, 10455545, 10456985, 10457423, 10457910, 10458738, 10459042, 10460511, 10461074, 10462910, 10463126, 10463262, 10463366, 10463600, 10464243, 10467003, 10467680, 10468429, 10469188, 10469200, 10470216, 10470510, 10471280, 10471520, 10471813, 10471978, 10472514, 10473087, 10473159, 10477025, 10477387, 10477954, 10478449, 10479247, 10479758, 10480611, 10480665, 10481054, 10481412, 10482213, 10482236, 10482613, 10482620, 10487872, 10489445, 10490515, 10490641, 10490663, 10490744, 10491495, 10492220, 10493470, 10493572, 10496348, 10497631, 10497976, 10498310, 10498433, 10499681, 10499861, 10500495.

Additional source detail variants (4)

Seats

Ford is conducting a safety recall to repair the third-row seat's latch mechanisms in approximately 196,667 model year (MY) 2004 through 2007 Ford Freestar and Mercury Monterey vehicles (see NHTSA recall 13V-081 for more details).The recall covers vehicles originally sold, or currently registered, in the salt belt states or high corrosion areas of the United States: Connecticut, Delaware, the District of Columbia, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, and Wisconsin.Approximately 100,000 remaining MY 2004-2007 Freestar and Monterey vehicles--those vehicles that were not originally sold, or are not currently registered, in salt belt states--are not included in the recall action. Although these vehicles are the same as the ones described above, they experience significantly lower failure rates because of reduced road salt exposure.ODI is currently aware of only one complaint on vehicle outside of the recall scope.ODI will monitor complaints and take further action if warranted by the circumstances.For owners of vehicles that are outside of the recall scope but exhibit the defect condition, owners (and affected Ford dealers) can contact Ford to request the recall repair.This Engineering Analysis is closed.See attached report and associated recall file for additional information.The ODI reports cited above can be reviewed online at http://www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following identification numbers: 10399896, 10410491, 10420028, 10424850, 10433928, 10436592, 10438529, 10440616, 10441489, 10441641, 10442809, 10446564, 10450295, 10450559, 10450587, 10452933, 10453826, 10454977, 10455545, 10456985, 10457423, 10457910, 10458738, 10459042, 10460511, 10461074, 10462910, 10463126, 10463262, 10463366, 10463600, 10464243, 10467003, 10467680, 10468429, 10469188, 10469200, 10470216, 10470510, 10471280, 10471520, 10471813, 10471978, 10472514, 10473087, 10473159, 10477025, 10477387, 10477954, 10478449, 10479247, 10479758, 10480611, 10480665, 10481054, 10481412, 10482213, 10482236, 10482613, 10482620, 10487872, 10489445, 10490515, 10490641, 10490663, 10490744, 10491495, 10492220, 10493470, 10493572, 10496348, 10497631, 10497976, 10498310, 10498433, 10499681, 10499861, 10500495.

Seats:mid/rear Assembly

Ford is conducting a safety recall to repair the third-row seat's latch mechanisms in approximately 196,667 model year (MY) 2004 through 2007 Ford Freestar and Mercury Monterey vehicles (see NHTSA recall 13V-081 for more details).The recall covers vehicles originally sold, or currently registered, in the salt belt states or high corrosion areas of the United States: Connecticut, Delaware, the District of Columbia, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, and Wisconsin.Approximately 100,000 remaining MY 2004-2007 Freestar and Monterey vehicles--those vehicles that were not originally sold, or are not currently registered, in salt belt states--are not included in the recall action. Although these vehicles are the same as the ones described above, they experience significantly lower failure rates because of reduced road salt exposure.ODI is currently aware of only one complaint on vehicle outside of the recall scope.ODI will monitor complaints and take further action if warranted by the circumstances.For owners of vehicles that are outside of the recall scope but exhibit the defect condition, owners (and affected Ford dealers) can contact Ford to request the recall repair.This Engineering Analysis is closed.See attached report and associated recall file for additional information.The ODI reports cited above can be reviewed online at http://www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following identification numbers: 10399896, 10410491, 10420028, 10424850, 10433928, 10436592, 10438529, 10440616, 10441489, 10441641, 10442809, 10446564, 10450295, 10450559, 10450587, 10452933, 10453826, 10454977, 10455545, 10456985, 10457423, 10457910, 10458738, 10459042, 10460511, 10461074, 10462910, 10463126, 10463262, 10463366, 10463600, 10464243, 10467003, 10467680, 10468429, 10469188, 10469200, 10470216, 10470510, 10471280, 10471520, 10471813, 10471978, 10472514, 10473087, 10473159, 10477025, 10477387, 10477954, 10478449, 10479247, 10479758, 10480611, 10480665, 10481054, 10481412, 10482213, 10482236, 10482613, 10482620, 10487872, 10489445, 10490515, 10490641, 10490663, 10490744, 10491495, 10492220, 10493470, 10493572, 10496348, 10497631, 10497976, 10498310, 10498433, 10499681, 10499861, 10500495.

Structure:body

Ford is conducting a safety recall to repair the third-row seat's latch mechanisms in approximately 196,667 model year (MY) 2004 through 2007 Ford Freestar and Mercury Monterey vehicles (see NHTSA recall 13V-081 for more details).The recall covers vehicles originally sold, or currently registered, in the salt belt states or high corrosion areas of the United States: Connecticut, Delaware, the District of Columbia, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, and Wisconsin.Approximately 100,000 remaining MY 2004-2007 Freestar and Monterey vehicles--those vehicles that were not originally sold, or are not currently registered, in salt belt states--are not included in the recall action. Although these vehicles are the same as the ones described above, they experience significantly lower failure rates because of reduced road salt exposure.ODI is currently aware of only one complaint on vehicle outside of the recall scope.ODI will monitor complaints and take further action if warranted by the circumstances.For owners of vehicles that are outside of the recall scope but exhibit the defect condition, owners (and affected Ford dealers) can contact Ford to request the recall repair.This Engineering Analysis is closed.See attached report and associated recall file for additional information.The ODI reports cited above can be reviewed online at http://www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following identification numbers: 10399896, 10410491, 10420028, 10424850, 10433928, 10436592, 10438529, 10440616, 10441489, 10441641, 10442809, 10446564, 10450295, 10450559, 10450587, 10452933, 10453826, 10454977, 10455545, 10456985, 10457423, 10457910, 10458738, 10459042, 10460511, 10461074, 10462910, 10463126, 10463262, 10463366, 10463600, 10464243, 10467003, 10467680, 10468429, 10469188, 10469200, 10470216, 10470510, 10471280, 10471520, 10471813, 10471978, 10472514, 10473087, 10473159, 10477025, 10477387, 10477954, 10478449, 10479247, 10479758, 10480611, 10480665, 10481054, 10481412, 10482213, 10482236, 10482613, 10482620, 10487872, 10489445, 10490515, 10490641, 10490663, 10490744, 10491495, 10492220, 10493470, 10493572, 10496348, 10497631, 10497976, 10498310, 10498433, 10499681, 10499861, 10500495.

Structure

Ford is conducting a safety recall to repair the third-row seat's latch mechanisms in approximately 196,667 model year (MY) 2004 through 2007 Ford Freestar and Mercury Monterey vehicles (see NHTSA recall 13V-081 for more details).The recall covers vehicles originally sold, or currently registered, in the salt belt states or high corrosion areas of the United States: Connecticut, Delaware, the District of Columbia, Illinois, Indiana, Iowa, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, and Wisconsin.Approximately 100,000 remaining MY 2004-2007 Freestar and Monterey vehicles--those vehicles that were not originally sold, or are not currently registered, in salt belt states--are not included in the recall action. Although these vehicles are the same as the ones described above, they experience significantly lower failure rates because of reduced road salt exposure.ODI is currently aware of only one complaint on vehicle outside of the recall scope.ODI will monitor complaints and take further action if warranted by the circumstances.For owners of vehicles that are outside of the recall scope but exhibit the defect condition, owners (and affected Ford dealers) can contact Ford to request the recall repair.This Engineering Analysis is closed.See attached report and associated recall file for additional information.The ODI reports cited above can be reviewed online at http://www-odi.nhtsa.dot.gov/owners/SearchNHTSAID under the following identification numbers: 10399896, 10410491, 10420028, 10424850, 10433928, 10436592, 10438529, 10440616, 10441489, 10441641, 10442809, 10446564, 10450295, 10450559, 10450587, 10452933, 10453826, 10454977, 10455545, 10456985, 10457423, 10457910, 10458738, 10459042, 10460511, 10461074, 10462910, 10463126, 10463262, 10463366, 10463600, 10464243, 10467003, 10467680, 10468429, 10469188, 10469200, 10470216, 10470510, 10471280, 10471520, 10471813, 10471978, 10472514, 10473087, 10473159, 10477025, 10477387, 10477954, 10478449, 10479247, 10479758, 10480611, 10480665, 10481054, 10481412, 10482213, 10482236, 10482613, 10482620, 10487872, 10489445, 10490515, 10490641, 10490663, 10490744, 10491495, 10492220, 10493470, 10493572, 10496348, 10497631, 10497976, 10498310, 10498433, 10499681, 10499861, 10500495.

PE11033 · Service Jack Failure

Opened Sep 13, 2011 · Closed Dec 7, 2012

Status: closed (inferred from source dates) · Equipment:mechanical:accessory Scissor/screw/bottle Jack/lift

The subject vehicles (SV) are all automatic transmission, front wheel drive vehicles with hand actuated mechanical park brakes. The investigation focused on allegations that the service jack failed and caused the vehicles to fall. The subject scissors-type jack appears to fail at the slotted hinge joints where the jack screw is located (bends at mid-point). The failures occur while the jack is in use, and vehicle movement (forward or backward) is typically reported coincident with the failure. Ford reported that most MY 2003 Windstar and all MY 2006-2007 Freestar/Monterey also use the subject jack, an additional 223,246 vehicles.NHTSA has received six consumer complaints (VOQs) involving three injury incidents and a fatality.Ford reported 26 complaints for the SVs involving an additional 4 injuries. In the fatal incident, the van fell on a person working on the engine under the otherwise unsupported vehicle; ODI was unable to determine whether the vehicle was adequately chocked or the park brake was properly set. Reported injuries include a broken arm, head and hand injuries, arm and rib bruises, and muscle strains. NHTSA has received just one new report since opening this investigation. The complaint trend in ODI and Ford data is flat if not declining.Ford provides instructions and warnings in the owner's manual, on a placard placed with the jack, and on the jack itself. These instruct consumers to put the vehicle gear selector in Park, properly set the parking brake, chock the opposite wheel, use the jack only for changing a tire, loosen the lug nuts prior to jacking, and to not get under a vehicle supported by the jack only (NHTSA also recommends that jacks only be used for tire changing).In the VOQs, roughly half the consumers were using the jack for something other than tire changing, half had not chocked a wheel, and half had not properly set the parking brake. ODI notes that since the front wheels are drive wheels (with an open center differential) the Park gear cannot provide vehicle stability (longitudinally) when a front wheel is raised. All NHTSA complaints and most of the complaints to Ford involved failures while a front wheel was raised.In response to ODI's inquiry, Ford conducted testing on a 2004 Freestar. Ford's tests showed that when a front tire was raised the service jack held without failing under various scenarios except when a rocking force was applied and the parking brake was not properly set. Based on its testing and its analysis of field data, Ford concluded that the type of jack failure evidenced in this investigation (bending at mid-point) was likely caused by vehicle movement due to an improperly secured vehicle, or other misuse of the jack. Ford notes that rates in this investigation were similar to those in another investigation (EA91-049) which ODI closed. ODI also analyzed jack data for MY 2003 and newer vehicles to compare to the SV population. To assist with this analysis, ODI requested data from the jack manufacturer (actually its successor company) who provided limited data but did identify other models using the same design jack. ODI was unable to identify a significant difference in the incidence of jack failures (including those involving bending failures) between the SVs, other vehicles which used the same jack, or other vehicles where the jack type was unknown or different.A safety-related defect has not been identified at this time and further use of agency resources does not appear to be warranted.Accordingly, investigation PE11-033 is closed. The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist and ODI reserves

PE10033 · Engine Stalling

Opened Aug 23, 2010 · Closed Jul 15, 2011

Status: closed (inferred from source dates) · Power Train:automatic Transmission:control Module (tcm/pcm/tecm); Vehicle Speed Control

The subject vehicles suffered from a design issue whereby water could run down onto the cowling under the hood and located in the area of the windshield wipers and then drip onto a computer module, the Powertrain Control Module (PCM), which could be manifested in a variety of symptoms depending on which part of the circuit board became wet or which of the connector pins shorted out.In addition to causing an engine to stall, which may or may not then restart, the water intrusion could also cause the transmission to shift poorly, the vehicle to have erratic power, a malfunction indicator light to come on, or result in an inability to start the vehicle, an inability to shift the vehicle into either forward or reverse. Also the problem could cause a higher than normal idle RPM in Park, or for the radio to malfunction, or the interior lights to stay on.During this investigation ODI was concerned with the effect of the engine stalling or a drastic and sudden loss of power either of which may create a safety risk.In reviewing the actual number of these types of incidents, collectively referred to here as engine stalls, the number was found to be below what would be considered a defect trend.For example, the number of engine stalls identified in Ford's warranty claims for the model year (MY) 2004 subject vehicles, the MY with the most failures, was 200 out of population of 125,865, for a failure rate of 0.16%.The one crash recorded by a complainant to NHTSA, VOQ 10311522, alleged that the engine stalled, due to water intrusion into the PCM, while the road was turning causing her to go off the road and according to the police report the vehicle then hit an embankment and a tree stump. Ford reported in their response that there were three alleged crashes but none of these were validated as being caused by a problem with water intrusion into the PCM causing a stall.Accordingly this investigation is closed.The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist.The agency will continue to monitor complaints and other information relating to the alleged defect in the subject vehicles and take further action in the future if warranted.

Additional source detail variants (2)

Power Train:automatic Transmission:control Module (tcm/pcm/tecm)

The subject vehicles suffered from a design issue whereby water could run down onto the cowling under the hood and located in the area of the windshield wipers and then drip onto a computer module, the Powertrain Control Module (PCM), which could be manifested in a variety of symptoms depending on which part of the circuit board became wet or which of the connector pins shorted out.In addition to causing an engine to stall, which may or may not then restart, the water intrusion could also cause the transmission to shift poorly, the vehicle to have erratic power, a malfunction indicator light to come on, or result in an inability to start the vehicle, an inability to shift the vehicle into either forward or reverse. Also the problem could cause a higher than normal idle RPM in Park, or for the radio to malfunction, or the interior lights to stay on.During this investigation ODI was concerned with the effect of the engine stalling or a drastic and sudden loss of power either of which may create a safety risk.In reviewing the actual number of these types of incidents, collectively referred to here as engine stalls, the number was found to be below what would be considered a defect trend.For example, the number of engine stalls identified in Ford's warranty claims for the model year (MY) 2004 subject vehicles, the MY with the most failures, was 200 out of population of 125,865, for a failure rate of 0.16%.The one crash recorded by a complainant to NHTSA, VOQ 10311522, alleged that the engine stalled, due to water intrusion into the PCM, while the road was turning causing her to go off the road and according to the police report the vehicle then hit an embankment and a tree stump. Ford reported in their response that there were three alleged crashes but none of these were validated as being caused by a problem with water intrusion into the PCM causing a stall.Accordingly this investigation is closed.The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist.The agency will continue to monitor complaints and other information relating to the alleged defect in the subject vehicles and take further action in the future if warranted.

Vehicle Speed Control

The subject vehicles suffered from a design issue whereby water could run down onto the cowling under the hood and located in the area of the windshield wipers and then drip onto a computer module, the Powertrain Control Module (PCM), which could be manifested in a variety of symptoms depending on which part of the circuit board became wet or which of the connector pins shorted out.In addition to causing an engine to stall, which may or may not then restart, the water intrusion could also cause the transmission to shift poorly, the vehicle to have erratic power, a malfunction indicator light to come on, or result in an inability to start the vehicle, an inability to shift the vehicle into either forward or reverse. Also the problem could cause a higher than normal idle RPM in Park, or for the radio to malfunction, or the interior lights to stay on.During this investigation ODI was concerned with the effect of the engine stalling or a drastic and sudden loss of power either of which may create a safety risk.In reviewing the actual number of these types of incidents, collectively referred to here as engine stalls, the number was found to be below what would be considered a defect trend.For example, the number of engine stalls identified in Ford's warranty claims for the model year (MY) 2004 subject vehicles, the MY with the most failures, was 200 out of population of 125,865, for a failure rate of 0.16%.The one crash recorded by a complainant to NHTSA, VOQ 10311522, alleged that the engine stalled, due to water intrusion into the PCM, while the road was turning causing her to go off the road and according to the police report the vehicle then hit an embankment and a tree stump. Ford reported in their response that there were three alleged crashes but none of these were validated as being caused by a problem with water intrusion into the PCM causing a stall.Accordingly this investigation is closed.The closing of this investigation does not constitute a finding by NHTSA that a safety-related defect does not exist.The agency will continue to monitor complaints and other information relating to the alleged defect in the subject vehicles and take further action in the future if warranted.

EA09016 · Transmission Torque Converter Failure

Opened Nov 10, 2009 · Closed Feb 2, 2012

Status: closed (inferred from source dates) · Power Train:automatic Transmission; Power Train:automatic Transmission:torque Converter

On January 4, 2012 Ford Motor Company submitted a Defect Information Report (NHTSA Recall No. 12V-006) to NHTSA regarding a defect in the performance of the transmission torque converter for approximately 205,896 Ford Freestar and Mercury Monterey vehicles.The supplier of the torque converter manufactured converters containing a pump shaft spline that did not consistently meet the specified heat treatment requirements.In normal use, the spline may wear excessively and eventually fails without warning.If a torque converter malfunctions due to a sheared pump drive spline, the vehicle will abruptly lose motive power.This problem affected model year 2004 and 2005 Freestar and Monterey minivans.During the investigation NHTSA identified 532 complaints alleging incidents of vehicle stall while driving due to torque converter failure.These failures were sudden and without any prior warning.Of the 490 complaints that reported the speed at the time of the failure:218 (44%) occurred at or above 55 mph; and 344 (70%) occurred at or above 40 mph.Of the 382 complaints that reported the position of the vehicle relative to traffic after it came to a stop following the loss of motive power: 122 (32%) alleged that the vehicle came to a stop in the flow of traffic and remained in the flow of traffic until pushed or towed out of the way; 225 (59%) reported that the vehicle was maneuvered to the side of the roadway and remained there until towed; and 35 (9%) reported that they were able to maneuver to a location away from the flow of traffic, such as a parking lot.Two crashes were allegedly caused by torque converter failure, including an incident in which a Freestar suddenly lost power in 65 mph traffic in an area where there was no shoulder available.As a result, the Freestar stopped in a travel lane and when trailing traffic maneuvered to avoid the stalled vehicle, a four vehicle collision occurred.In these types of circumstances NHTSA believes the defect presents an unreasonable risk to motor vehicle safety and so advised Ford.In its Defect Information Report, Ford refers to its response to NHTSA's Preliminary Evaluation information request, which stated that a vehicle that loses motive power due to torque converter malfunction remains readily controllable; the vehicle will coast during which it can be safely maneuvered and stopped because the engine continues to run.Because the engine continues to run, steering and braking are unaffected, and the vehicle's electrical system and directional signals remain functional.In view of the foregoing, NHTSA does not agree with this statement.This investigation is closed based on Ford's recall.

Additional source detail variants (2)

Power Train:automatic Transmission

On January 4, 2012 Ford Motor Company submitted a Defect Information Report (NHTSA Recall No. 12V-006) to NHTSA regarding a defect in the performance of the transmission torque converter for approximately 205,896 Ford Freestar and Mercury Monterey vehicles.The supplier of the torque converter manufactured converters containing a pump shaft spline that did not consistently meet the specified heat treatment requirements.In normal use, the spline may wear excessively and eventually fails without warning.If a torque converter malfunctions due to a sheared pump drive spline, the vehicle will abruptly lose motive power.This problem affected model year 2004 and 2005 Freestar and Monterey minivans.During the investigation NHTSA identified 532 complaints alleging incidents of vehicle stall while driving due to torque converter failure.These failures were sudden and without any prior warning.Of the 490 complaints that reported the speed at the time of the failure:218 (44%) occurred at or above 55 mph; and 344 (70%) occurred at or above 40 mph.Of the 382 complaints that reported the position of the vehicle relative to traffic after it came to a stop following the loss of motive power: 122 (32%) alleged that the vehicle came to a stop in the flow of traffic and remained in the flow of traffic until pushed or towed out of the way; 225 (59%) reported that the vehicle was maneuvered to the side of the roadway and remained there until towed; and 35 (9%) reported that they were able to maneuver to a location away from the flow of traffic, such as a parking lot.Two crashes were allegedly caused by torque converter failure, including an incident in which a Freestar suddenly lost power in 65 mph traffic in an area where there was no shoulder available.As a result, the Freestar stopped in a travel lane and when trailing traffic maneuvered to avoid the stalled vehicle, a four vehicle collision occurred.In these types of circumstances NHTSA believes the defect presents an unreasonable risk to motor vehicle safety and so advised Ford.In its Defect Information Report, Ford refers to its response to NHTSA's Preliminary Evaluation information request, which stated that a vehicle that loses motive power due to torque converter malfunction remains readily controllable; the vehicle will coast during which it can be safely maneuvered and stopped because the engine continues to run.Because the engine continues to run, steering and braking are unaffected, and the vehicle's electrical system and directional signals remain functional.In view of the foregoing, NHTSA does not agree with this statement.This investigation is closed based on Ford's recall.

Power Train:automatic Transmission:torque Converter

On January 4, 2012 Ford Motor Company submitted a Defect Information Report (NHTSA Recall No. 12V-006) to NHTSA regarding a defect in the performance of the transmission torque converter for approximately 205,896 Ford Freestar and Mercury Monterey vehicles.The supplier of the torque converter manufactured converters containing a pump shaft spline that did not consistently meet the specified heat treatment requirements.In normal use, the spline may wear excessively and eventually fails without warning.If a torque converter malfunctions due to a sheared pump drive spline, the vehicle will abruptly lose motive power.This problem affected model year 2004 and 2005 Freestar and Monterey minivans.During the investigation NHTSA identified 532 complaints alleging incidents of vehicle stall while driving due to torque converter failure.These failures were sudden and without any prior warning.Of the 490 complaints that reported the speed at the time of the failure:218 (44%) occurred at or above 55 mph; and 344 (70%) occurred at or above 40 mph.Of the 382 complaints that reported the position of the vehicle relative to traffic after it came to a stop following the loss of motive power: 122 (32%) alleged that the vehicle came to a stop in the flow of traffic and remained in the flow of traffic until pushed or towed out of the way; 225 (59%) reported that the vehicle was maneuvered to the side of the roadway and remained there until towed; and 35 (9%) reported that they were able to maneuver to a location away from the flow of traffic, such as a parking lot.Two crashes were allegedly caused by torque converter failure, including an incident in which a Freestar suddenly lost power in 65 mph traffic in an area where there was no shoulder available.As a result, the Freestar stopped in a travel lane and when trailing traffic maneuvered to avoid the stalled vehicle, a four vehicle collision occurred.In these types of circumstances NHTSA believes the defect presents an unreasonable risk to motor vehicle safety and so advised Ford.In its Defect Information Report, Ford refers to its response to NHTSA's Preliminary Evaluation information request, which stated that a vehicle that loses motive power due to torque converter malfunction remains readily controllable; the vehicle will coast during which it can be safely maneuvered and stopped because the engine continues to run.Because the engine continues to run, steering and braking are unaffected, and the vehicle's electrical system and directional signals remain functional.In view of the foregoing, NHTSA does not agree with this statement.This investigation is closed based on Ford's recall.

PE09033 · Torque Converter Output Shaft Failure

Opened Jul 15, 2009 · Closed Nov 17, 2009

Status: closed (inferred from source dates) · Power Train:automatic Transmission; Power Train:automatic Transmission:torque Converter

ODI HAS RECEIVED 227 OWNER COMPLAINTS ALLEGING A SUDDEN AND UNEXPECTED LOSS OF MOTIVE POWER DUE TO AN INTERNAL TRANSMISSION FAILURE IN THE SUBJECT VEHICLES.OF THOSE COMPLAINTS, 124 CAN BE ATTRIBUTED TO THE TORQUE CONVERTER OUTPUT SHAFT SPLINES STRIPPING CAUSING A SUDDEN LOSS OF POWER TO THE DRIVETRAIN.THE REMAINING 103 COMPLAINTS EXPERIENCED A LOSS OF MOTIVE POWER BUT THE SPECIFIC INTERNAL FAILURE CAUSE WITHIN THE TRANSMISSION IS NOT KNOWN.ODI HAS UPGRADED THE INVESTIGATION TO AN ENGINEERING ANALYSIS (EA09-016) TO CONTINUE ITS ASSESSMENT OF THE SCOPE, FREQUENCY AND SAFETY-RELATED CONSEQUENCES OF THE ALLEGED DEFECT.

Additional source detail variants (2)

Power Train:automatic Transmission

ODI HAS RECEIVED 227 OWNER COMPLAINTS ALLEGING A SUDDEN AND UNEXPECTED LOSS OF MOTIVE POWER DUE TO AN INTERNAL TRANSMISSION FAILURE IN THE SUBJECT VEHICLES.OF THOSE COMPLAINTS, 124 CAN BE ATTRIBUTED TO THE TORQUE CONVERTER OUTPUT SHAFT SPLINES STRIPPING CAUSING A SUDDEN LOSS OF POWER TO THE DRIVETRAIN.THE REMAINING 103 COMPLAINTS EXPERIENCED A LOSS OF MOTIVE POWER BUT THE SPECIFIC INTERNAL FAILURE CAUSE WITHIN THE TRANSMISSION IS NOT KNOWN.ODI HAS UPGRADED THE INVESTIGATION TO AN ENGINEERING ANALYSIS (EA09-016) TO CONTINUE ITS ASSESSMENT OF THE SCOPE, FREQUENCY AND SAFETY-RELATED CONSEQUENCES OF THE ALLEGED DEFECT.

Power Train:automatic Transmission:torque Converter

ODI HAS RECEIVED 227 OWNER COMPLAINTS ALLEGING A SUDDEN AND UNEXPECTED LOSS OF MOTIVE POWER DUE TO AN INTERNAL TRANSMISSION FAILURE IN THE SUBJECT VEHICLES.OF THOSE COMPLAINTS, 124 CAN BE ATTRIBUTED TO THE TORQUE CONVERTER OUTPUT SHAFT SPLINES STRIPPING CAUSING A SUDDEN LOSS OF POWER TO THE DRIVETRAIN.THE REMAINING 103 COMPLAINTS EXPERIENCED A LOSS OF MOTIVE POWER BUT THE SPECIFIC INTERNAL FAILURE CAUSE WITHIN THE TRANSMISSION IS NOT KNOWN.ODI HAS UPGRADED THE INVESTIGATION TO AN ENGINEERING ANALYSIS (EA09-016) TO CONTINUE ITS ASSESSMENT OF THE SCOPE, FREQUENCY AND SAFETY-RELATED CONSEQUENCES OF THE ALLEGED DEFECT.