NHTSA owner reports · September 18, 2026 snapshot.
Engine complaints
74 reportsClear category filter135,000 miles · Sep 29, 2017
Engine
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING VARIOUS SPEEDS, THE VEHICLE STARTED TO MISFIRE. THE CONTACT NOTICED CARBON BUILD UP ON THE SPARK PLUG HEAD, WHICH CAUSED IT TO CEMENT ONTO THE ENGINE. THE VEHICLE WAS TAKEN TO FORD OF HONOLULU (1370 N KING ST, HONOLULU, HAWAII, 96817, PHONE NUMBER: (808) 824-3981) WHERE IT WA…
Read full complaint
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING VARIOUS SPEEDS, THE VEHICLE STARTED TO MISFIRE. THE CONTACT NOTICED CARBON BUILD UP ON THE SPARK PLUG HEAD, WHICH CAUSED IT TO CEMENT ONTO THE ENGINE. THE VEHICLE WAS TAKEN TO FORD OF HONOLULU (1370 N KING ST, HONOLULU, HAWAII, 96817, PHONE NUMBER: (808) 824-3981) WHERE IT WAS DIAGNOSED THAT A "CRAPPY" DESIGN WAS ON THE SPARK PLUG THAT NEEDED TO BE REPLACED. THE DEALER REPLACED ALL FOUR SPARK PLUGS, BUT FRACTURED ONE OF THEM. THE CONTACT WAS INFORMED THAT HE WOULD HAVE TO PAY TO REPLACE THE FRACTURED SPARK PLUG. THE SPARK PLUG WAS NOT REPLACED DUE TO THE REPLACEMENT FEE. THE MANUFACTURER WAS CONTACTED AND REFERRED THE CONTACT TO NHTSA. THE APPROXIMATE FAILURE MILEAGE WAS 135,000.
NHTSA ODI #11030549
134,600 miles · Sep 20, 2017
Engine
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING VARIOUS SPEEDS OR WHEN THE VEHICLE WAS STARTED, THE REDUCED POWER ENGINE WARNING INDICATOR ILLUMINATED. THE VEHICLE WAS TAKEN TO THE DEALER (MULLINAX FORD OF CENTRAL FLORIDA, 1551 E SEMORAN BLVD, APOPKA, FL 32703) WHERE IT WAS DIAGNOSED THAT THE COOLANT PIPE NEEDED TO BE REPL…
Read full complaint
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING VARIOUS SPEEDS OR WHEN THE VEHICLE WAS STARTED, THE REDUCED POWER ENGINE WARNING INDICATOR ILLUMINATED. THE VEHICLE WAS TAKEN TO THE DEALER (MULLINAX FORD OF CENTRAL FLORIDA, 1551 E SEMORAN BLVD, APOPKA, FL 32703) WHERE IT WAS DIAGNOSED THAT THE COOLANT PIPE NEEDED TO BE REPLACED. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS CONTACTED AT 800-392-3673 AND STATED THAT THE CONTACT NEEDED TO CALL NHTSA. A CASE NUMBER WAS NOT PROVIDED. THE APPROXIMATE FAILURE MILEAGE WAS 134,600.
NHTSA ODI #11024567
116,000 miles · Jun 8, 2017
EngineFuel/propulsion SystemService Brakes
FORD F150 XLT 2006 SHOULD HAVE A MANDATORY SAFETY RECALL FOR THE FUEL CONTROL MODULE. THIS IS CLEARLY A DESIGN DEFECT AND A MAJOR SAFETY CONCERN. I WAS DRIVING DOWN VT116 (A HILLY, WINDING 2 LANE COUNTRY HIGHWAY WITH NO SHOULDER) IN THE RAIN AT ABOUT 40MPH WHEN MY TRUCK STARTED TO BUCK AND LOSE POWER. THERE WAS NO PLACE TO …
Read full complaint
FORD F150 XLT 2006 SHOULD HAVE A MANDATORY SAFETY RECALL FOR THE FUEL CONTROL MODULE. THIS IS CLEARLY A DESIGN DEFECT AND A MAJOR SAFETY CONCERN. I WAS DRIVING DOWN VT116 (A HILLY, WINDING 2 LANE COUNTRY HIGHWAY WITH NO SHOULDER) IN THE RAIN AT ABOUT 40MPH WHEN MY TRUCK STARTED TO BUCK AND LOSE POWER. THERE WAS NO PLACE TO PULL OVER, SO I PUT MY HAZARDS ON AND TRIED TO LIMP IT TO A SAFE PLACE TO PULL OVER. THE ENGINE STALLED AND I LOST STEERING AND BRAKING POWER ON A CURVE. I APPLIED THE BRAKES MANUALLY AND WRESTLED THE STEERING WHEEL (WHICH NO LONGER HAD ANY POWER ASSIST). WITH MAJOR DIFFICULTY, I WAS ABLE TO BRING THE TRUCK TO A CONTROLLED STOP. I WAS THEN ABLE TO RESTART THE ENGINE, LIMPED ALONG AT 15MPH, BUCKING AND STALLING 3 MORE TIMES BEFORE GETTING TO A SAFE PLACE TO PULL OVER. THIS IS THE SECOND TIME I HAVE HAD MY FCM REPLACED (PRIOR WAS 1/5/2013) AND THE SECOND TIME I ALMOST CRASHED MY TRUCK BECAUSE OF THIS DEFECT. THE PREVIOUS TIME WAS JANUARY 2013 ON A MOUNTAIN ROAD IN WINTER ON SNOW. IF I WAS TOWING MY BOAT ON THE INTERSTATE AND LOST ALL POWER, I WOULD PROBABLY HAVE BEEN KILLED ALONG WITH ANYONE AROUND ME. WHY IS IT A DESIGN DEFECT? BECAUSE THIS ELECTRONIC COMPONENT IS INSTALLED IN A WEATHER-EXPOSED AREA ABOVE THE SPARE TIRE AND IS NOT CORROSION-PROOF. IN ANY RUST BELT STATE (OR A PLACE EXPOSED TO SALT), THE CASE WILL CORRODE, EXPOSING THE CIRCUIT BOARD TO WATER, CAUSING THE UNIT TO FAIL. WHY IS IT A SAFETY CONCERN? BECAUSE WHEN THE FCM FAILS, THE ENGINE WILL STALL, CAUSING A LOSS OF POWER TO THE STEERING AND BRAKING SYSTEMS. NHTSA SHOULD FORCE FORD TO DO A MANDATORY RECALL AND REDESIGN THIS POORLY DESIGNED PART. EVEN THE REPLACEMENT PARTS FAIL AFTER A FEW YEARS. CONSIDERING HOW MANY F150'S ARE ON THE ROAD AND HOW MANY OF THEM CARRY OR TOW HEAVY LOADS, I'D SAY THIS SHOULD BE A TOP PRIORITY FOR BOTH FORD AND NHTSA. RECALL!
NHTSA ODI #10993883
128,000 miles · Apr 20, 2017
EngineService Brakes
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING 45 MPH, THE FRONT OF THE VEHICLE SHOOK VIOLENTLY, THE ENGINE NEARLY STALLED AND LOST POWER REPEATEDLY, AND THE CHECK ENGINE INDICATOR ILLUMINATED INTERMITTENTLY. THE VEHICLE ALSO BRAKED INDEPENDENTLY. THE VEHICLE WAS TAKEN TO AN UNCERTIFIED MECHANIC WHO DIAGNOSED THAT THE ENG…
Read full complaint
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING 45 MPH, THE FRONT OF THE VEHICLE SHOOK VIOLENTLY, THE ENGINE NEARLY STALLED AND LOST POWER REPEATEDLY, AND THE CHECK ENGINE INDICATOR ILLUMINATED INTERMITTENTLY. THE VEHICLE ALSO BRAKED INDEPENDENTLY. THE VEHICLE WAS TAKEN TO AN UNCERTIFIED MECHANIC WHO DIAGNOSED THAT THE ENGINE WAS HAVING MULTIPLE MISFIRES, AND DID NOT KNOW HOW TO REPAIR THE VEHICLE. THE CONTACT ALSO CALLED A DEALER WHO WAS EXTREMELY RUDE AND DID NOT ASSIST. THE VEHICLE WAS NOT REPAIRED. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE CONTACT WAS INFORMED THAT THEY WOULD NOT ASSIST BECAUSE THE CLAIMS DEADLINE HAD BEEN MISSED. THE APPROXIMATE FAILURE MILEAGE WAS 128,000.
NHTSA ODI #10979677
117,000 miles · Dec 25, 2016
EngineService BrakesSteering
WAS DRIVING MY 2006 F-150 OVER A MOUNTAIN PASS IN CANADA. THERE WAS COMPACT SNOW AND ICE ON THE ROADWAY AND I WAS TRAVELING WITH OTHER VEHICLES AROUND ME AT APPROXIMATELY 40 MPH. THE VEHICLES AHEAD OF ME BEGAN TO BRAKE, I AS WELL TRIED TO BRAKE ONLY TO FIND MY TRUCK HAD LOST POWER AND WAS NO LONGER RUNNING. I HAD LOST POWER TO M…
Read full complaint
WAS DRIVING MY 2006 F-150 OVER A MOUNTAIN PASS IN CANADA. THERE WAS COMPACT SNOW AND ICE ON THE ROADWAY AND I WAS TRAVELING WITH OTHER VEHICLES AROUND ME AT APPROXIMATELY 40 MPH. THE VEHICLES AHEAD OF ME BEGAN TO BRAKE, I AS WELL TRIED TO BRAKE ONLY TO FIND MY TRUCK HAD LOST POWER AND WAS NO LONGER RUNNING. I HAD LOST POWER TO MY BRAKES AND STEERING. THIS CAUSED MY TRUCK TO BEGIN SLIDING ON THE SNOW AND ICE AND I WAS UNABLE TO CONTROL MY VEHICLE. THE CARS AROUND ME WERE SLOWING AND STOPPING AND I COULD NOT. I BEGAN TO FISH TAIL IN BOTH DIRECTIONS WHILE TRYING DESPERATELY TO CONTROL MY TRUCK WITH NO BRAKES OR POWER STEERING, I EVENTUALLY DID A COMPLETE 360 DEGREE SPIN AND SOMEHOW MANAGED TO GET THE TRUCK UNDER CONTROL WITH OUT ROLLING OVER AND INTO THE DITCH OR SMASHING INTO THE OTHER VEHICLES AROUND ME. WHEN I CAME TO A STOP MY TRUCK WAS NOT RUNNING AND THE DASH LIGHTS WERE ON. I PLACED THE TRANSMISSION INTO DRIVE AND RESTARTED THE TRUCK WITHOUT ISSUE AND CONTINUED ON WITHOUT ISSUE. THIS IS THE SECOND TIME THIS HAS HAPPENED WITH THIS TRUCK, THE FIRST TIME I WAS ON A RESIDENTIAL STREET AND I WAS ABLE TO JUST COAST TO A STOP AND RESTARTED THE TRUCK. THIS LAST INCIDENT ON THE MOUNTAIN PASS HAS CONFIRMED TO ME THAT I WILL NOT OWN ANOTHER FORD AS I HAVE RESEARCHED THIS PROBLEM TO FIND THAT THIS IS A COMMON ISSUE WITH FORD TRUCKS. I AM CERTAIN THIS HAS CAUSED MAJOR ACCIDENTS IF NOT DEATHS AND THE FACT THERE ARE NO ERROR CODES LEFT BEHIND FROM THE EVENTS TO VERIFY THIS HAS HAPPENED WE MAY NEVER KNOW. THE FACT IT HAS HAPPENED TO ME TWICE AND ONCE ONLY A MIRACLE A SERIOUS ACCIDENT DIDN'T OCCUR I AM DONE WITH THE FORD MOTOR COMPANY. *TR
NHTSA ODI #10937392
136,000 miles · Dec 3, 2016
Engine
I WAS DRIVING ON THE ROAD WHEN THE "ENGINE FAILSAFE WARNING' LIGHT CAME ON. THE ENTIRE ENGINE SHUT DOWN. NO POWER AT ALL. VERY HARD TO STOP AND STEER. I NEARLY GOT INTO AN ACCIDENT. ANOTHER TIME I WAS ENTERING PARKING LOT WHEN IT HAPPENED. I HAD THE THROTTLE BODY REPLACED TO FIX THE PROBLEM. BUT SHUTTING OFF THE ENGINE ON…
Read full complaint
I WAS DRIVING ON THE ROAD WHEN THE "ENGINE FAILSAFE WARNING' LIGHT CAME ON. THE ENTIRE ENGINE SHUT DOWN. NO POWER AT ALL. VERY HARD TO STOP AND STEER. I NEARLY GOT INTO AN ACCIDENT. ANOTHER TIME I WAS ENTERING PARKING LOT WHEN IT HAPPENED. I HAD THE THROTTLE BODY REPLACED TO FIX THE PROBLEM. BUT SHUTTING OFF THE ENGINE ON A WARNING WHILE DRIVING IS VERY DANGEROUS. SOME INTERNET RESEARCH INDICATES THIS IS NOT A LONE OCCURRENCE.
NHTSA ODI #10929707
111,000 miles · Oct 19, 2016
EngineVehicle Speed Control
TL* THE CONTACT OWNS A 2006 FORD F-150. THE CONTACT STATED THAT THE VEHICLE WOULD SHOOK WHENEVER THE VEHICLE WAS IDLING. THE SHAKING INCREASED DURING ACCELERATION. THE CONTACT TOOK THE VEHICLE TO A DEALER WHO WAS UNABLE TO IDENTIFY THE CAUSE OF THE FAILURE, BUT INFORMED THE CONTACT THAT THE SHAKING WAS A COMMON ISSUE WITH THE YE…
Read full complaint
TL* THE CONTACT OWNS A 2006 FORD F-150. THE CONTACT STATED THAT THE VEHICLE WOULD SHOOK WHENEVER THE VEHICLE WAS IDLING. THE SHAKING INCREASED DURING ACCELERATION. THE CONTACT TOOK THE VEHICLE TO A DEALER WHO WAS UNABLE TO IDENTIFY THE CAUSE OF THE FAILURE, BUT INFORMED THE CONTACT THAT THE SHAKING WAS A COMMON ISSUE WITH THE YEAR, MAKE, AND MODEL. THE VEHICLE WAS NOT REPAIRED AND THE FAILURE RECURRED. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 111,000.
NHTSA ODI #10917391
101,000 miles · Oct 12, 2016
Engine
TOOK TRUCK IN FOR ROUTINE 100,000 MAINTENANCE AND TUNE UP. SPARK PLUG STUCK IN THE CYLINDER HEAD AND ENDED UP GETTING CHARGED $3,500 FOR THE REPAIR. I AM READING ONLINE OF HOW WIDESPREAD THIS PROBLEM IS AND FORD SHOULD RECALL THESE SPARK PLUGS AND TAKE CARE OF THEIR CUSTOMERS. I WILL NEVER PURCHASE ANOTHER FORD IN MY LIFETIME …
Read full complaint
TOOK TRUCK IN FOR ROUTINE 100,000 MAINTENANCE AND TUNE UP. SPARK PLUG STUCK IN THE CYLINDER HEAD AND ENDED UP GETTING CHARGED $3,500 FOR THE REPAIR. I AM READING ONLINE OF HOW WIDESPREAD THIS PROBLEM IS AND FORD SHOULD RECALL THESE SPARK PLUGS AND TAKE CARE OF THEIR CUSTOMERS. I WILL NEVER PURCHASE ANOTHER FORD IN MY LIFETIME IF THEY DON'T DO SOMETHING ABOUT THIS.
NHTSA ODI #10915674
158,818 miles · Sep 30, 2016
Engine
TL* THE CONTACT OWNS A 2006 FORD F-150. WHILE DRIVING 8 MPH, THE VEHICLE STALLED WITHOUT WARNING AFTER A SHARP RIGHT TURN. THE CHECK ENGINE INDICATOR ILLUMINATED. THE VEHICLE WAS TAKEN TO BE REPAIRED, BUT THE ISSUE RECURRED. THE MANUFACTURER WAS MADE AWARE OF THE ISSUE. THE FAILURE MILEAGE WAS 158,818.
NHTSA ODI #10910800
107,000 miles · Sep 25, 2016
EngineSteeringStructure
POWER STEERING HOSE RUST AND LEAKING-TRANSMISSION HOSES RUSTED AND LEAKING - SPARK PLUG BREAKING OFF WHEN HAVING THEM REPLACED
NHTSA ODI #10909520
Official recalls
4Feb 23, 2011
FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.
Consequence & remedy
Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.
Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.
May 7, 2008
FORD IS RECALLING 605,684 MY 2005-2006 F-150 AND LINCOLN MARK LT VEHICLES EQUIPPED WITH 5.4L 3-VALVE ENGINES. THE BRAKE BOOSTER VACUUM SUPPLY HOSE ATTACHED TO THE INTAKE MANIFOLD FITTING MAY SWELL OVER TIME AND LOSE RETENTION FORCE. THIS CONDITION COULD ALLOW THE HOSE TO BECOME DETACHED FROM THE FITTING DURING AN INTAKE MANIFOLD BACKFIRE. SHOULD THE HOSE DETACH FROM THE INTAKE MANIFOLD, SEVERAL BRAKE APPLICATIONS WITH POWER ASSIST WILL BE AVAILABLE BEFORE THE VACUUM RESERVE IS DEPLETED.
Consequence & remedy
Consequence: ONCE THE BRAKE BOOSTER VACUUM RESERVE IS DEPLETED, THE DRIVER WILL HAVE FOUNDATION BRAKE FUNCTION, BUT WITH INCREASED BRAKE PEDAL EFFORT. REDUCED VEHICLE BRAKING COULD LEAD TO A CRASH.
Remedy: DEALERS WILL REPLACE A RUBBER HOSE ON THE BRAKE BOOSTER VACUUM SUPPLY TUBE ASSEMBLY. THE RECALL BEGAN ON JUNE 27, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Feb 6, 2006
CERTAIN PICKUP TRUCKS FAIL TO COMPLY WITH EITHER THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD (FMVSS) NO. 105, 'HYDRAULIC AND ELECTRIC BRAKE SYSTEMS' OR FMVSS NO. 135, 'PASSENGER CAR BRAKE SYSTEMS.' THESE VEHICLES WERE BUILT WITH A SOFTWARE ERROR IN THE INSTRUMENT CLUSTER.
Consequence & remedy
Consequence: THIS ERROR COULD PREVENT THE ANTILOCK BRAKE SYSTEM (ABS) WARNING LIGHT FROM ILLUMINATING IF THE ABS MODULE EVER BECAME INOPERATIVE.
Remedy: DEALERS WILL RECALIBRATE THE INSTRUMENT CLUSTER IN THESE VEHICLES. THE RECALL BEGAN ON FEBRUARY 27, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.
Nov 9, 2005
ON CERTAIN TRUCKS, PASSENGER CARS AND SPORT UTILITY VEHICLES, THE WINDSHIELD WIPER MOTOR MAY HAVE BEEN PRODUCED WITHOUT GREASE BEING APPLIED TO THE OUTPUT SHAFT GEAR.
Consequence & remedy
Consequence: AFTER A PERIOD OF CONTINUOUS USE ON THE HIGH SPEED SETTING, LACK OF GREASE ON THE OUTPUT SHAFT GEAR MAY CAUSE THE GEAR TO DISTORT OR FRACTURE DURING OPERATION RESULTING IN A LOSS OF WIPER FUNCTION. INOPERATIVE WIPERS UNDER INCLEMENT WEATHER CONDITIONS COULD CAUSE A CRASH DUE TO IMPAIRED VISIBILITY.
Remedy: DEALERS WILL INSPECT THE WIPER MOTOR FOR THE PRESENCE OF GREASE AND GREASE THE WIPER MOTOR GEARS IF NECESSARY. THE RECALL BEGAN ON NOVEMBER 22, 2005. OWNERS MAY CONTACT FORD AT 1-800-392-3673 OR LINCOLN/MERCURY AT 1-800-521-4140.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
2EA10001 · Inadvertent Airbag Deployment
Opened Jan 13, 2010 · Closed Apr 25, 2011
Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Additional source detail variants (4)
Air Bags
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:driver Side:inflator Module
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
Air Bags:frontal:sensor/control MODULE-INACTIVE
ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.
PE08001 · Loss Of Brake POWER-ASSIST
Opened Jan 8, 2008 · Closed May 9, 2008
Status: closed (inferred from source dates) · Service Brakes, Hydraulic:power Assist; Service Brakes, Hydraulic:power Assist:vacuum; Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Additional source detail variants (3)
Service Brakes, Hydraulic:power Assist
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.
Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings
BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.