← New search

2005 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 2005 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

973 reports with mileage · 139 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Visibility. Review the 260 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine. Review the 117 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 112 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

50 crash reports29 fire reports48 injury reports

What owners actually said

1,112 reports
74,800 miles · Jun 13, 2014
Electrical System

I STARTED THE TRUCK AND THE ALL THE INITIAL BEFORE ENGINE STARTS LIGHTS CAME ON, TACHOMETER WENT TO ZERO AND THERE WAS A WARNING BUZZER. I RAPPED THE TOP OF THE DASH AFTER TRYING THREE RESTARTS WHERE NOTHING CHANGED. THE TRUCK NORMALIZED AND I DROVE IT. I DO NOT OFTEN DRIVE THE TRUCK, SO ABOUT THREE WEEKS LATER I WAS HEADED TO …

Read full complaint

I STARTED THE TRUCK AND THE ALL THE INITIAL BEFORE ENGINE STARTS LIGHTS CAME ON, TACHOMETER WENT TO ZERO AND THERE WAS A WARNING BUZZER. I RAPPED THE TOP OF THE DASH AFTER TRYING THREE RESTARTS WHERE NOTHING CHANGED. THE TRUCK NORMALIZED AND I DROVE IT. I DO NOT OFTEN DRIVE THE TRUCK, SO ABOUT THREE WEEKS LATER I WAS HEADED TO PENNSYLVANIA AND WAS ABOUT TO ENTER THE HRBT TUNNEL WHEN THE INSTRUMENT CLUSTER WENT TO KEY ON STATUS (NO TACHOMETER OR SPEEDOMETER FUNCTION, MULTITUDE OF WARNING LIGHTS AND WARNING BUZZER). SO AT 55MPH I HIT THE TOP OF THE DASH AND THE INSTRUMENT CLUSTER BRIEFLY CAME BACK ON THEN SHUT OFF AGAIN. I REPEATED THE BLOW ON THE TOP OF THE DASH AND THE PROBLEM WENT AWAY FOR ABOUT FIVE HOURS AND THEN CAME BACK AGAIN. IT'S QUITE DISCONCERTING TO HAVE THE SPEEDOMETER SHUT DOWN WHILE DRIVING AND THE REST OF THE INSTRUMENT CLUSTER NOT FUNCTION. THIS CONTINUES TO HAPPEN AND FORD'S FIX IS FOR ME TO HAVE TO SPEND APPROXIMATELY $900.00 TO COMPLETELY REPLACE THE CLUSTER. *JS

NHTSA ODI #10598145

68,685 miles · Jun 5, 2014
Engine

5.4L TRUCK ALWAYS MAINTAINED AND SERVICED AT FORD DEALERSHIPS. IT WAS RUNNING PERFECT UNTIL IT IMMEDIATELY BEGAN IDLING ROUGH AT A STOP. NO CHECK ENGINE LIGHT, WE JUST KNOW OUR TRUCK. TOOK IT IN FOR A TUNE-UP (REPLACED SPARK PLUGS, ETC.) AND OIL CHANGE. PERFECT BILL OF HEALTH - COULDN'T REPLICATE PROBLEM. ENGINE CHECKED OUT DIA…

Read full complaint

5.4L TRUCK ALWAYS MAINTAINED AND SERVICED AT FORD DEALERSHIPS. IT WAS RUNNING PERFECT UNTIL IT IMMEDIATELY BEGAN IDLING ROUGH AT A STOP. NO CHECK ENGINE LIGHT, WE JUST KNOW OUR TRUCK. TOOK IT IN FOR A TUNE-UP (REPLACED SPARK PLUGS, ETC.) AND OIL CHANGE. PERFECT BILL OF HEALTH - COULDN'T REPLICATE PROBLEM. ENGINE CHECKED OUT DIAGNOSTICALLY- PERFECT. THEY SUGGESTED IT COULD BE AN INTERMITTENT STICKING FUEL INJECTOR, SO WE WERE GOING TO GET AN ADDITIVE TO ADD TO THE FUEL TANK. DIDN'T MAKE IT THAT FAR. DROVE IT HOME - 35 MILES - GOT HOME AND ENGINE STALLED IN DRIVEWAY. TURNED BACK ON, ENGINE DIED AGAIN. LONG STORY SHORT - TOWED IT BACK TO FORD - THEY WERE ABLE TO REPLICATE THE PROBLEM - OIL PRESSURE DROPS SUDDENLY (INTERMITTENTLY)- POINTING TO CAM PHASER, TIMING AREA OF ENGINE - END RESULT - NEED NEW ENGINE - THIS ONE IS SHOT AT ONLY 68K MILES - ESTIMATED COST $7,400 PLUS TAX. EXTENDED WARRANTY EXPIRED. DID SOME INTERNET RESEARCH, APPEARS TO BE A COMMON PROBLEM. THESE 5.4L ENGINES ARE BREAKING DOWN LEFT AND RIGHT IN THESE TRUCKS. DON'T KNOW WHAT CHANGED. HAD A 1999 EXPEDITION WITH A 5.4L - GREAT VEHICLE. CONTACTED FORD CUSTOMER CARE - WAS TOLD TO KEEP ALL RECEIPTS IN THE EVENT OF A RECALL. AN ENGINE SHOULD NOT BLOW AT 68K MILES, ESPECIALLY A BUILT FORD TOUGH ENGINE. WE'VE OWNED FORDS SINCE HIGH SCHOOL AND THEY USED TO BE RELIABLE, LONG DRIVING VEHICLES. *TR

NHTSA ODI #10596310

130,000 miles · Jun 4, 2014
EnginePower Train

I BOUGHT A 2005 FORD F 150 USED NOT KNOWING ABOUT THE ENGINE AND REAR END PROBLEMS UNTIL I HEARD THE RATTLE COMING FROM UNDER THE HOOD SO I GO ASK DEALER ABOUT THIS PROBLEM HE SAID THIS TYPE ENGINE WAS FROM FORD WAS NOT GOOD LUCKY FOR ME THEY WERE REPAIRING ONE IT HAD BLOWN A SPARK PLUG OUT AND THEY WERE REPLACE PARTS FOR THE CA…

Read full complaint

I BOUGHT A 2005 FORD F 150 USED NOT KNOWING ABOUT THE ENGINE AND REAR END PROBLEMS UNTIL I HEARD THE RATTLE COMING FROM UNDER THE HOOD SO I GO ASK DEALER ABOUT THIS PROBLEM HE SAID THIS TYPE ENGINE WAS FROM FORD WAS NOT GOOD LUCKY FOR ME THEY WERE REPAIRING ONE IT HAD BLOWN A SPARK PLUG OUT AND THEY WERE REPLACE PARTS FOR THE CAM HE SAID GET RID OF THE TRUCK OR RUN IT TILL IT BLOWS UP IT HAS NO POWER IT STALLS IN THE MOST BAD PLACES I AM AFRAID I AM GOING TO HAVE A WRECK AND HURT SOME ONE FORD NEEDS TO RECALL THESE ENGINE AND FIX THE REAR END PROBLEM ALSO I DON'T HAVE 5 TO 8 GRAND TO FIX IT. *TR

NHTSA ODI #10596154

49,000 miles · Jun 2, 2014
Service Brakes

ON 6/01/2014 I WAS DRIVING MY TRUCK WHEN I STARTED TO APPROACH AN INTERSECTION TO STOP AND WHEN I PRESSED THE BRAKE PEDAL TO STOP AND THE TRUCK THE BRAKES WOULD NOT ACTIVATE. THE BRAKE PEDAL WENT ALL AWAY TO THE FLOOR, THEN I REALIZED THAT EITHER I WOULD HAVE TO CRASH THE TRUCK INTO THE WALL OF THE BRIDGE AND POSSIBLY GO OVER OR…

Read full complaint

ON 6/01/2014 I WAS DRIVING MY TRUCK WHEN I STARTED TO APPROACH AN INTERSECTION TO STOP AND WHEN I PRESSED THE BRAKE PEDAL TO STOP AND THE TRUCK THE BRAKES WOULD NOT ACTIVATE. THE BRAKE PEDAL WENT ALL AWAY TO THE FLOOR, THEN I REALIZED THAT EITHER I WOULD HAVE TO CRASH THE TRUCK INTO THE WALL OF THE BRIDGE AND POSSIBLY GO OVER OR CRASH THE TRUCK IN TO OTHER VEHICLES. HOWEVER THIS WAS A PANICKY SITUATION IN THE LAST SECOND BEFORE CRASHING THE TRUCK I APPLIED THE EMERGENCY BRAKES. AFTER TOWING THE TRUCK TO THE GARAGE I TOOK FEW PHOTOS OF THE FRONT BRAKE LINE HOSES AND HOW CLOSE THEY ARE TO THE TIRE RIMS. ONE OF THOSE BREAK LINES WERE DAMAGE BY RUBBING AGAINST THE TIRE RIM. OTHER BREAK LINES PHOTO IS SHOWING HOW CLOSE THE BREAK LINES ARE TO THE TIRE RIM. I AM VERY DISAPPOINTED THAT FORD WOULD INSTALL OR DESIGN THE HOLDING BRACKETS THAT COULD POSSIBLY MOVE CLOSE TO THE TIRE RIM FOR THE BRAKE HOSES THAT CLOSE TO THE TIRE RIM. ALSO I STOP OVER TO A FORD DEALER IN READING PA WHY THEY WOULD NOT ADDRESS THIS PROBLEM WHEN I HAVE THE TRUCK INSPECTED IN OCTOBER OF 2013. THE SUPERVISOR AT THE DESK HAVE NO ANSWER TO MY QUESTION. THEN I CHECK SIMILAR TRUCKS THE YEAR WAS 2008 AND THE BRAKE LINE WAS LESS THAN .250" FROM THE TIRE RIM. WHEN I CHECKED THE 2014 E150 IT LOOKS THAT THE BRAKE LINES LOCATION WERE REDESIGN. SO OBVIOUSLY SOMEBODY NEW ABOUT THIS PROBLEM HOWEVER I WAS NEVER NOTIFY ABOUT THIS PROBLEM, THE BRACKET THAT HOLD THE BRAKE LINES WERE NEVER ADJUSTED AWAY FROM BEING THAT CLOSE TO A TIRE RIM AT THE INSPECTION. I AM DISAPPOINTED THAT A GOVERNMENT AGENCY WOULD ALLOW THE BREAK HOSES TO BE INSTALLED ABOUT .250" FROM THE TIRE RIMS OR MOVING PARTS. I WOULD LIKE TO BE REIMBURSED FOR A TOWING AND THE REPAIR OF THE TRUCK. *TR

NHTSA ODI #10595703

93,000 miles · May 21, 2014
EngineFire

I HAD JUST CHANGED THE OIL AND CHECKED THE FLUIDS AND HAD TO RUN SOME ERRANDS UP TOWN ABOUT A MILE AND A HALF UP THE ROAD THE ENGINE STARTED MAKING A KNOCKING NOISE, I WAS CLOSE ENOUGH TO THE GARAGE I USE SO I PULLED IN THERE TO SEE WHAT WAS GOING ON THE OIL PAN WAS ON FIRE OIL AND WHAT LOOKED LIKE ANTI FREEZE WAS COMING OUT OF …

Read full complaint

I HAD JUST CHANGED THE OIL AND CHECKED THE FLUIDS AND HAD TO RUN SOME ERRANDS UP TOWN ABOUT A MILE AND A HALF UP THE ROAD THE ENGINE STARTED MAKING A KNOCKING NOISE, I WAS CLOSE ENOUGH TO THE GARAGE I USE SO I PULLED IN THERE TO SEE WHAT WAS GOING ON THE OIL PAN WAS ON FIRE OIL AND WHAT LOOKED LIKE ANTI FREEZE WAS COMING OUT OF A HOLE FROM WHAT USE TO BE THE OIL PAN OR WHAT WAS LEFT OF THE PAN, THE FELLOW THAT RAN THE STATION TOLD ME IT HAD HYDRO LOCKED AND BENT A ROD AND PUSHED IT THRU THE OIL PAN, HE WENT ON TO SAY HE HAD SEEN SEVERAL OF THE 4.2 DO THIS AND IT LOOKED LIKE FORD WOULD HAVE DONE SOMETHING WHEN THEY WERE AWARE OF THE PROBLEMS WITH THE 4.2,I TALKED TO FORD ABOUT IT AND GOT THE RUN AROUND FROM THEM, JUST COULDN'T BELIEVE IT I HAD NEVER PULLED OR HAULED ANY HEAVY OBJECTS OR MISTREATED IT IN ANY WAY, DON'T UNDERSTAND WHEN THE POWERS THAT BE WERE AWARE OF THE PROBLEM WITH THIS ENGINE THE CONSUMER WAS LEFT HOLDING THE BAG TO A TUNE OF THOUSANDS OF DOLLARS IN REPAIRS, NOW GOT TO DO WITH OUT TO TRY AND SAVE THE MONEY TO GET IT FIXED, MOSTLY USED THE TRUCK TO GET MY WIFE BACK AND FORTH TO THE DR. SHE HAS M/S AND A HEART CONDITION, THE POOR ALWAYS CATCH IT IF THERE WAS ANYTHING TO FORD THEY WOULD MAKE IT GOOD AND THE SAME GOES FOR THE NHTSA THEY KNOW THE PROBLEM IS THERE JUST LOOK AT THE FORD FORMS, BUT GOD ALWAYS MAKES A WAY JUST HAVE TO WAIT AND SEE WHAT HIS PLAN ARE, ALOT OF FOLKS LIKE US HAVE NO FAMILY SO WE TAKE CARE OF OR TRUCKS, IT SURE WASN'T ABUSE THAT CAUSE THE PROBLEM. *TR

NHTSA ODI #10593142

40,000 miles · Apr 26, 2014
Engine And Engine CoolingFuel System, Gasoline

FORD FUEL PUMP DRIVER CORRODES BADLY CAUSING NO START AND/OR TOTAL FAILURE OF ENGINE POWER. REDUCTION OF POWER OR ENGINE STALLING CAN AND WILL HAPPEN AT HIGHWAY SPEEDS. WHEN ENGINE STALLS DRIVER CAN LOSE POWER STEERING POWER BRAKES AND CONTROL VEHICLE. THIS IS KNOWN BY FORD. FORD ALONG WITH A AFTERMAKET COMPANY HAS REDESIGNED TH…

Read full complaint

FORD FUEL PUMP DRIVER CORRODES BADLY CAUSING NO START AND/OR TOTAL FAILURE OF ENGINE POWER. REDUCTION OF POWER OR ENGINE STALLING CAN AND WILL HAPPEN AT HIGHWAY SPEEDS. WHEN ENGINE STALLS DRIVER CAN LOSE POWER STEERING POWER BRAKES AND CONTROL VEHICLE. THIS IS KNOWN BY FORD. FORD ALONG WITH A AFTERMAKET COMPANY HAS REDESIGNED THE PART. THE UPDATED PART HAS STANDOFFS ALONG WITH A PROTECTIVE COATING PREVENTING CORROSION. THE CORROSION OF THE PART HAPPENS FASTER IN THE SALT BELT STATES. I REPLACED MINE AND THE PART HAD A HOLE IN IT LETTING WATER AND PARTS OF METAL INSIDE UNIT. I STILL HAVE PART IF NEEDED. DO AN INTERNET SEARCH AND YOU WILL FIND ALLOT OF EXAMPLES OF THIS ISSUE. THIS ISSUE AFFECTS MILLIONS OF VEHICLES. *TR

NHTSA ODI #10585087

Mileage unknown · Apr 24, 2014
Structure

BAD PERFORATION CORROSION AROUND WHEEL ARCHES. PAINT BLISTERING. *TR

NHTSA ODI #10584746

80,000 miles · Apr 23, 2014
Engine

THE 5.4L ENGINE INSTALLED IN THE FORD F150 HAS NOTHING BUT A BAD REPUTATION FOR COSTING CONSUMERS THOUSANDS AND NEVER BEING ABLE TO FULLY FIX THE ISSUE WITHOUT REPLACING THE ENTIRE ENGINE. THE VEHICLE CUTS OUT OF POWER, SHAKES VIGOROUSLY, MISFIRES AND IS DANGEROUS ON HIGHWAYS, HILLS, OR ANY ROADWAY FOR THAT MATTER. OUR PERSONAL …

Read full complaint

THE 5.4L ENGINE INSTALLED IN THE FORD F150 HAS NOTHING BUT A BAD REPUTATION FOR COSTING CONSUMERS THOUSANDS AND NEVER BEING ABLE TO FULLY FIX THE ISSUE WITHOUT REPLACING THE ENTIRE ENGINE. THE VEHICLE CUTS OUT OF POWER, SHAKES VIGOROUSLY, MISFIRES AND IS DANGEROUS ON HIGHWAYS, HILLS, OR ANY ROADWAY FOR THAT MATTER. OUR PERSONAL EXPERIENCE ALMOST GOT US REAR ENDED BY A SEMI TRUCK WITH OUR CHILDREN IN THE VEHICLE BECAUSE WE COULD NOT GET IT TO MOVE WITHOUT LOSING POWER AND SHAKING AND JERKING! THERE HAVE BEEN SEVERAL THOUSAND COMPLAINTS FILED ON THIS ENGINE I'M SURE, JUDGING BY THE FORUMS, WEBSITES, CAR COMPLAINT SITES ETC. MEANWHILE, WE TOOK OUR TRUCK INTO A FORD DEALERSHIP AND WERE TOLD THAT THEY GET HUNDREDS OF PEOPLE WHO BRING THESE VEHICLES IN AND SPEND THOUSANDS TO REPLACE THE CAM PHASERS JUST TO HAVE THE SAME ISSUE THE NEXT MONTH! BY THE TIME YOU ARE ABLE TO FIX THE PROBLEM YOU'VE PUT OUT MORE MONEY THAN THE VEHICLE IS WORTH AT THAT POINT! GET THESE ENGINES RECALLED AND GET THEM OFF THE ROADS. THEY'RE UNSAFE FOR DRIVERS, FAMILIES AND OTHERS ON THE ROADWAYS! *TR

NHTSA ODI #10584384

125,000 miles · Apr 22, 2014
Power Train

VEHICLE WENT INTO 'FAILSAFE MODE' AND STOPPED RUNNING WITH NO WARNING. MANUAL SAID THIS WOULD ALLOW THE VEHICLE TO PROCEED SAFELY HOME. DID NOT GET FAR BEFORE IT WOULD NOT RUN. WHEN IT DID RUN, IT RAN AT ABOUT 2 MPH BEFORE FAILING TO GO ANY FARTHER. LOOKING ON THE INTERNET, LOTS OF PEOPLE HAVE HAD THIS OCCUR WITH VARIOUS FO…

Read full complaint

VEHICLE WENT INTO 'FAILSAFE MODE' AND STOPPED RUNNING WITH NO WARNING. MANUAL SAID THIS WOULD ALLOW THE VEHICLE TO PROCEED SAFELY HOME. DID NOT GET FAR BEFORE IT WOULD NOT RUN. WHEN IT DID RUN, IT RAN AT ABOUT 2 MPH BEFORE FAILING TO GO ANY FARTHER. LOOKING ON THE INTERNET, LOTS OF PEOPLE HAVE HAD THIS OCCUR WITH VARIOUS FORD VEHICLES. *TR

NHTSA ODI #10584132

152,000 miles · Mar 31, 2014
Fuel System, Gasoline

ENGINE CUT OUT WHILE DRIVING VEHICLE. WOULD NOT RESTART. BECAUSE I WAS STRANDED IN THE MIDDLE OF A BUSY ROAD, THERE WAS A 2 CAR REAR COLLISION THAT OCCURRED BEHIND ME. REPAIRS WERE $400.00 FOR ME NOT TO MENTION THE COST AND INJURY OF THE OTHER CARS INVOLVED IN THE ACCIDENT BEHIND ME. I HAVE SINCE LEARNED THAT THIS FUEL PUMP MOD…

Read full complaint

ENGINE CUT OUT WHILE DRIVING VEHICLE. WOULD NOT RESTART. BECAUSE I WAS STRANDED IN THE MIDDLE OF A BUSY ROAD, THERE WAS A 2 CAR REAR COLLISION THAT OCCURRED BEHIND ME. REPAIRS WERE $400.00 FOR ME NOT TO MENTION THE COST AND INJURY OF THE OTHER CARS INVOLVED IN THE ACCIDENT BEHIND ME. I HAVE SINCE LEARNED THAT THIS FUEL PUMP MODULE IS A COMMON PROBLEM IN THIS TRUCK DUE TO CORROSION PROBLEMS RESULTING FROM A POOR DESIGN. IT IS MY OPINION THAT THIS SHOULD BE A RECALLED ITEM. *TR

NHTSA ODI #10576062

Official recalls

3

11V107000 · Air Bags:frontal:driver Side:inflator Module

Feb 23, 2011

FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.

Consequence & remedy

Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

08V208000 · Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

May 7, 2008

FORD IS RECALLING 605,684 MY 2005-2006 F-150 AND LINCOLN MARK LT VEHICLES EQUIPPED WITH 5.4L 3-VALVE ENGINES. THE BRAKE BOOSTER VACUUM SUPPLY HOSE ATTACHED TO THE INTAKE MANIFOLD FITTING MAY SWELL OVER TIME AND LOSE RETENTION FORCE. THIS CONDITION COULD ALLOW THE HOSE TO BECOME DETACHED FROM THE FITTING DURING AN INTAKE MANIFOLD BACKFIRE. SHOULD THE HOSE DETACH FROM THE INTAKE MANIFOLD, SEVERAL BRAKE APPLICATIONS WITH POWER ASSIST WILL BE AVAILABLE BEFORE THE VACUUM RESERVE IS DEPLETED.

Consequence & remedy

Consequence: ONCE THE BRAKE BOOSTER VACUUM RESERVE IS DEPLETED, THE DRIVER WILL HAVE FOUNDATION BRAKE FUNCTION, BUT WITH INCREASED BRAKE PEDAL EFFORT. REDUCED VEHICLE BRAKING COULD LEAD TO A CRASH.

Remedy: DEALERS WILL REPLACE A RUBBER HOSE ON THE BRAKE BOOSTER VACUUM SUPPLY TUBE ASSEMBLY. THE RECALL BEGAN ON JUNE 27, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

06V033000 · Interior Lighting

Feb 6, 2006

CERTAIN PICKUP TRUCKS FAIL TO COMPLY WITH EITHER THE REQUIREMENTS OF FEDERAL MOTOR VEHICLE SAFETY STANDARD (FMVSS) NO. 105, 'HYDRAULIC AND ELECTRIC BRAKE SYSTEMS' OR FMVSS NO. 135, 'PASSENGER CAR BRAKE SYSTEMS.' THESE VEHICLES WERE BUILT WITH A SOFTWARE ERROR IN THE INSTRUMENT CLUSTER.

Consequence & remedy

Consequence: THIS ERROR COULD PREVENT THE ANTILOCK BRAKE SYSTEM (ABS) WARNING LIGHT FROM ILLUMINATING IF THE ABS MODULE EVER BECAME INOPERATIVE.

Remedy: DEALERS WILL RECALIBRATE THE INSTRUMENT CLUSTER IN THESE VEHICLES. THE RECALL BEGAN ON FEBRUARY 27, 2006. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

3

EA10001 · Inadvertent Airbag Deployment

Opened Jan 13, 2010 · Closed Apr 25, 2011

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Additional source detail variants (4)

Air Bags

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:driver Side:inflator Module

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

PE09046 · Inadvertent Airbag Deployment

Opened Sep 24, 2009 · Closed Jan 19, 2010

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Additional source detail variants (4)

Air Bags

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal:driver Side:inflator Module

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

Air Bags:frontal:sensor/control MODULE-INACTIVE

FORD REPORTS THAT THE INADVERTENT AIRBAG DEPLOYMENTS ARE MOST LIKELY CAUSED BY THE AIRBAG HORN MOUNTING PLATE'S SHARP METAL EDGE THAT EVENTUALLY CAN CHAFE/CUT THE AIRBAG CLOCKSPRING JUMPER WIRE LEADING TO A SHORT-TO-GROUND CONDITION.ONE HUNDRED EIGHTY TWO (182) OF THE 230 REPORTS WERE FOR AIRBAG DEPLOYMENTS RESULTING IN 56 INJURIES WITH REMAINING 48 REPORTS FOR AN AIRBAG LIGHT ILLUMINATION CONDITION.INJURIES INCLUDE ABRASION, CONTUSION AND CUTS TO THE ARM/HAND/FACE AND/OR UPPER BODY REGIONS.ONE OWNER REPORTED A BROKEN TOOTH AND TWO OWNERS REPORTED BEING KNOCKED UNCONSCIOUS AS A RESULT OF THE AIRBAG DEPLOYMENT.IN ADDITION, MY2004 AND MY2006 F-150 VEHICLES ALSO CONTAIN THE SAME DESIGN THAT RESULTED IN AN ADDITIONAL 89 REPORTS WITH 37 AIRBAG DEPLOYMENTS AND NINE INJURIES. FORD MADE AN INTERIM DESIGN CHANGE TO THE HORN MOUNTING PLATE IN JANUARY 2006 AND THEN MAJOR CHANGES TO THE HORN MOUNTING PLATE, AIRBAG MODULE AND CLOCKSPRING JUMPER WIRE DESIGNS IN JUNE 2006 FOR THE MY2007 VEHICLES.THIS PRELIMINARY EVALUATION IS UPGRADED TO AN ENGINEERING ANALYSIS (EA10-001) TO INCLUDE MY2004-2006 F-150 VEHICLES AND TO FURTHER EVALUATE THE CONDITION.

PE08001 · Loss Of Brake POWER-ASSIST

Opened Jan 8, 2008 · Closed May 9, 2008

Status: closed (inferred from source dates) · Service Brakes, Hydraulic:power Assist; Service Brakes, Hydraulic:power Assist:vacuum; Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Additional source detail variants (3)

Service Brakes, Hydraulic:power Assist

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Service Brakes, Hydraulic:power Assist:vacuum

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.

Service Brakes, Hydraulic:power Assist:vacuum:hoses, Lines/piping, And Fittings

BY LETTER DATED MAY 5, 2008, FORD MOTOR COMPANY (FORD) NOTIFIED THE AGENCY THAT IT WILL CONDUCT A SAFETY RECALL (NHTSA RECALL NUMBER 08V-208) TO ADDRESS A MANUFACTURING DEFECT IN APPROXIMATELY 605,684 MODEL YEAR (MY) 2005 AND 2006 FORD F-150 AND LINCOLN MARK LT VEHICLES ORIGINALLY EQUIPPED WITH THE 5.4L DISPLACEMENT, 3-VALVE PER CYLINDER, V-8 ENGINE.THE RECALLED VEHICLES WERE BUILT FROM JULY 18, 2004 THROUGH MAY 31, 2006 AT THE DEARBORN TRUCK PLANT; FROM MAY 4, 2004 THROUGH MAY 31, 2006 AT THE KANSAS CITY ASSEMBLY PLANT; AND FROM APRIL 19, 2004 THROUGH MAY 31, 2006 AT THE NORFOLK TRUCK PLANT.THE VEHICLES WERE MANUFACTURED WITH THE SAME DEFECTIVE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY UNIQUE TO THE 5.4L V-8 ENGINE.FORD F-150 VEHICLES EQUIPPED WITH OPTIONALLY AVAILABLE 4.2L V6 AND 4.6L V-8 ENGINES ARE NOT INCLUDED IN THIS RECALL ACTION BECAUSE THEY UTILIZE A DIFFERENT, ONE-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT DOES NOT EXHIBIT AN APPARENT DEFECT TREND. THE RECALLED VEHICLES UTILIZE A TWO-PIECE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY COMPRISED OF A STANDPIPE ASSEMBLY AND VACUUM HOSE.THE STANDPIPE ASSEMBLY ATTACHES TO A FITTING ON THE ENGINE AIR INTAKE MANIFOLD UTILIZING A FLEXIBLE RUBBER HOSE AND PLASTIC ELBOW.THE VACUUM HOSE ATTACHES TO THE OPPOSITE END OF THE STANDPIPE ASSEMBLY AND CONNECTS TO A CHECK VALVE FITTING AT THE BRAKE BOOSTER ASSEMBLY.ACCORDING TO FORD, THE PORTION OF THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY ATTACHED TO THE INTAKE MANIFOLD MAY SWELL OVER TIME AND LOSE RETENTION FORCE, WHICH MAY ALLOW THE HOSE TO BECOME DETACHED FROM THE INTAKE MANIFOLD.SHOULD THE BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY BE DISRUPTED, APPLICATION OF THE BRAKE PEDAL MAY DEPLETE THE VACUUM RESERVE AND CONSEQUENTLY RESULT IN LOSS OF BRAKE POWER-ASSIST. TO CORRECT THE SAFETY DEFECT, FORD WILL INSTALL AN IMPROVED DESIGN BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY THAT UTILIZES A HOSE CLAMP AT THE INTAKE MANIFOLD ATTACHMENT. THIS REMEDY WILL BE PROVIDED FREE OF CHARGE FOR ALL RECALLED VEHICLES.LATER PRODUCTION FORD F-150 AND LINCOLN MARK LT VEHICLES BUILT AFTER MAY 2006 WERE MANUFACTURED WITH A HOSE CLAMP AT THE BRAKE BOOSTER VACUUM SUPPLY HOSE/INTAKE MANIFOLD ATTACHMENT AND ARE NOT AFFECTED. TO DATE, THE OFFICE OF DEFECTS INVESTIGATION (ODI) IS AWARE OF 324 NON-DUPLICATIVE COMPLAINTS AND 14 NON-INJURY CRASHES RELATED TO THE ALLEGED DEFECT IN THE SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF 4,465 SUBJECT VEHICLES THAT EXPERIENCED ONE OR MORE WARRANTY CLAIMS TO REPAIR OR REPLACE THE SUBJECT BRAKE BOOSTER VACUUM SUPPLY HOSE ASSEMBLY. THE ACTION TAKEN BY FORD IS SUFFICIENT TO RESOLVE THE ISSUES RAISED BY THIS INVESTIGATION.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.