← New search

2004 Ford F-150

Owner reports · Recalls · Investigations

More warning signs than most F-150 years

Owner complaints for the 2004 Ford F-150 are substantially higher than the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

1,749 reports with mileage · 280 unknown

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Visibility. Review the 841 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Power Train. Review the 232 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 167 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

75 crash reports40 fire reports58 injury reports

Power Train complaints

232 reports
Clear category filter
73,000 miles · Feb 23, 2012
Power Train

THE CLUTCH PACK IN THE DRIVEN TRAIN REAR DIFFERENTIALS LOCK UP WHEN TURNING CORNERS AND HOWLS WHEN GOING DOWN THE ROAD. THESE FAILURES ARE SO COMMON ON FORD TRUCK THAT FORD IS NOW ADDING FRICTION MODIFIERS TO THE REAR DIFFERENTIALS TO REAR THE PROBLEM AND AFTERMARKET SUPPLIERS ARE MAKING REPLACEMENTS FOR THE CLUTCH PACK LIKE DE…

Read full complaint

THE CLUTCH PACK IN THE DRIVEN TRAIN REAR DIFFERENTIALS LOCK UP WHEN TURNING CORNERS AND HOWLS WHEN GOING DOWN THE ROAD. THESE FAILURES ARE SO COMMON ON FORD TRUCK THAT FORD IS NOW ADDING FRICTION MODIFIERS TO THE REAR DIFFERENTIALS TO REAR THE PROBLEM AND AFTERMARKET SUPPLIERS ARE MAKING REPLACEMENTS FOR THE CLUTCH PACK LIKE DETROIT LOCKER TO ELIMINATE THE PROBLEM. THIS LOCK UP ON WINTER SURFACES CAUSE THE WHEELS TO LOOSE TRACTION INCREASING THE POTENTIAL FOR ACCIDENTS. THE HOWLING SOUND IS ALSO A DRAG ON THE DRIVE TRAIN COMPONENTS, REDUCING MPG AND CAPABILITY OF THE VEHICLE TO HANDLE ADVERSE CONDITIONS. FORD HAS KNOWN ABOUT THIS PROBLEM FOR SEVERAL YEARS AND HAS DONE NOTHING TO FIX THE PROBLEM OR REIMBURSE OWNERS FOR THE COST OF REPAIR. ON MY TRUCK, TOTAL REAR END REPAIR COSTS HAVE EXCEEDED $3700. *TR

NHTSA ODI #10449048

4,000 miles · Feb 10, 2012
Power Train

TL* THE CONTACT OWNS A 2004 FORD F-150. THE CONTACT STATED THAT THE VEHICLE BEGAN TO VIOLENTLY SHAKE WHILE DRIVING 35 MPH. THE VEHICLE WAS MANEUVERED TO THE SHOULDER AND THE CONTACT NOTICED THAT THE REAR DIFFERENTIAL FAILED. THE DEALER MADE THREE ATTEMPTS TO DUPLICATE THE FAILURE. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILU…

Read full complaint

TL* THE CONTACT OWNS A 2004 FORD F-150. THE CONTACT STATED THAT THE VEHICLE BEGAN TO VIOLENTLY SHAKE WHILE DRIVING 35 MPH. THE VEHICLE WAS MANEUVERED TO THE SHOULDER AND THE CONTACT NOTICED THAT THE REAR DIFFERENTIAL FAILED. THE DEALER MADE THREE ATTEMPTS TO DUPLICATE THE FAILURE. THE MANUFACTURER WAS NOT MADE AWARE OF THE FAILURE. NO REPAIRS WERE PERFORMED. THE FAILURE MILEAGE WAS 4,000 AND THE CURRENT MILEAGE WAS 62,000.

NHTSA ODI #10447447

35,000 miles · Jan 23, 2012
Power TrainService Brakes, HydraulicSuspension

I'M DRIVING MY TRUCK WHEN ALL OF A SUDDEN IT WILL START VIBRATING HORRIBLY, LIKE DRIVING OVER A WASHBOARD TYPE OF ROAD. THE ONLY WAY TO GET IT TO STOP IS TO PULL OVER TO THE SIDE OF THE HIGHWAY, PUT IT IN PARK, WAIT, AND THEN TRY TO RESUME DRIVING. BUT THIS DOES NOT ALWAYS WORK. YOU SOMETIMES HAVE TO STOP AND CHANGE TO PARK, …

Read full complaint

I'M DRIVING MY TRUCK WHEN ALL OF A SUDDEN IT WILL START VIBRATING HORRIBLY, LIKE DRIVING OVER A WASHBOARD TYPE OF ROAD. THE ONLY WAY TO GET IT TO STOP IS TO PULL OVER TO THE SIDE OF THE HIGHWAY, PUT IT IN PARK, WAIT, AND THEN TRY TO RESUME DRIVING. BUT THIS DOES NOT ALWAYS WORK. YOU SOMETIMES HAVE TO STOP AND CHANGE TO PARK, OR REVERSE, A COUPLE OF TIMES, BEFORE DRIVING AGAIN SO THAT THE VIBRATION GOES AWAY. I HAVE COMPLAINED ABOUT THIS BEFORE, AND I SEE HUNDREDS OF COMPLAINTS FOR THE SAME ISSUE ON "FORD OWNER WEBSITES", AND EVERYBODY IS PISSED. NOBODY CAN GET AN ANSWER FROM FORD SERVICE AS TO WHAT IS WRONG. MANY PEOPLE HAVE REPLACED MANY DIFFERENT THINGS (I.E. TRANSMISSION, CLUTCH PADS, BEARINGS, U-JOINTS, EMERGENCY BRAKE CABLE OR PADS), ALL TO NO AVAIL. THEY HAVE WASTED THEIR TIME AND MONEY, AND FORD REFUSES TO LIVE UP TO THIS AWFUL AND VERY DANGEROUS PROBLEM. APPARENTLY, FORD KNOWS THIS IS A BIG PROBLEM WITH 2004 F-150 TRUCKS, ESPECIALLY, BUT WILL NOT ACKNOWLEDGE IT. SOMEONE WROTE ON THE WEB THAT FORD KNOWS THEY HAD A RETOOLING PROBLEM WITH THESE TRUCKS, AND LET THE TRUCKS GO OUT FOR SALE ANYWAY. I AM NOW HAVING THIS PROBLEM MORE OFTEN, AND I AM AFRAID TO DRIVE IT. I DO NOT HAVE ANY MONEY TO FIX MY TRUCK, SINCE OUR ECONOMY IS SO BAD AND HAVE BEEN UNEMPLOYED FOR YEARS. MAKE FORD TAKE OWNERSHIP OF THIS RECALL PROBLEM! *TR

NHTSA ODI #10444836

36,100 miles · Dec 27, 2011
Power Train

TRUCK WOULD NOT START EVEN THOUGH LIGHTS, DASH INDICATORS, & RADIO CAME ON. CHECKED UNDER HOOD & THEN PLACED IN NEUTRAL TO TRY & START. VEHICLE STARTED IN NEUTRAL. PLACED VEHICLE IN PARK AND UPON TAKING FOOT OFF BRAKE, VEHICLE LURCHED BACKWARD (IN REVERSE) ALMOST GOING OVER AN EMBANKMENT WHEN I SLAMMED BRAKES. VEHICLE SHIFT INDI…

Read full complaint

TRUCK WOULD NOT START EVEN THOUGH LIGHTS, DASH INDICATORS, & RADIO CAME ON. CHECKED UNDER HOOD & THEN PLACED IN NEUTRAL TO TRY & START. VEHICLE STARTED IN NEUTRAL. PLACED VEHICLE IN PARK AND UPON TAKING FOOT OFF BRAKE, VEHICLE LURCHED BACKWARD (IN REVERSE) ALMOST GOING OVER AN EMBANKMENT WHEN I SLAMMED BRAKES. VEHICLE SHIFT INDICATOR SHOWED IT IN PARK BUT, TRANSMISSION WAS ACTUALLY STILL IN REVERSE. COULD NOT GET SHIFT TO ENGAGE INTO PARK. PLACED VEHICLE INTO GARAGE WITH EMERGENCY BRAKE SECURED UNTIL COULD DETERMINE PROBLEM. RESEARCH INDICATED FORD HAD A RECALL (RECALL - #97V171000) FOR THIS EXACT ISSUE ON 1997-1998 MODELS ONLY. BUT, APPARENTLY IT IS STILL A PROBLEM ON LATER MODELS. COULD NOT FIND A RECALL ON 2004 MODEL. NOTE THAT THIS CONDITION ALMOST CAUSED A SERIOUS ACCIDENT. *TR

NHTSA ODI #10441282

121,000 miles · Dec 12, 2011
Power Train

STARTED MY TRUCK AS USUAL TO GO TO WORK, PUT IT IN REVERSE AND IT WAS LIKE I PUT IT IN NEUTRAL, NO ENGAGEMENT AT ALL. GLAD I WASN'T IN A SITUATION WHEN THIS HAPPENED THAT COULD HAVE PUT MYSELF OR SOMEONE ELSE IN DANGER. FORD KNOWS THEY HAVE A PROBLEM, IT IS WIDE SPREAD. SURE MY TRUCK HAS 124000 MILES ON IT BUT THE TRANSMISSION M…

Read full complaint

STARTED MY TRUCK AS USUAL TO GO TO WORK, PUT IT IN REVERSE AND IT WAS LIKE I PUT IT IN NEUTRAL, NO ENGAGEMENT AT ALL. GLAD I WASN'T IN A SITUATION WHEN THIS HAPPENED THAT COULD HAVE PUT MYSELF OR SOMEONE ELSE IN DANGER. FORD KNOWS THEY HAVE A PROBLEM, IT IS WIDE SPREAD. SURE MY TRUCK HAS 124000 MILES ON IT BUT THE TRANSMISSION MALFUNCTION LIGHT HAS BEEN GOING ON AND OFF FOR THE LAST 70000 MILES AND THE DEALER SAID THEY COULD NOT FIND ANY TROUBLE CODES OR MALFUNCTIONS DURING THIS PERIOD. I CAN REV MY MOTOR TO ABOUT 2000 RPM AND IT WILL FINALLY GENTLY START TO ROLL INTO REVERSE BUT MY FAILSAFE MODE ENGAGES, CHECK ENGINE LIGHT COMES ON AND THE MOTOR STUMBLES BADLY UNTIL I PUT THE VEHICLE IN DRIVE GEAR AND GO ABOUT 2 MILES AT WHICH TIME THE FAILSAFE MODE GOES OFF AND IT SMOOTHES OUT. FOR THE MOST PART MY VEHICLE HAS BEEN DEALER MAINTAINED. *TR

NHTSA ODI #10439435

115,215 miles · Dec 7, 2011
Power Train

WHEN I TURN LEFT OR RIGHT I CAN FEEL A SHAKE OR VIBRATION COMING FROM THE REAREND. *TR

NHTSA ODI #10438830

Mileage unknown · Sep 29, 2011
Power Train

THE REAR DIFFERENTIAL IS MAKING A CHATTERING NOISE AT LOW SPEEDS. IT HAS A POSI-TRAC REAR DIFFERENTIAL, AND I CAN FEEL A 'STOP AND GO' TYPE ACTION AS I AM DRIVING IN A STRAIGHT LINE AT LOW SPEEDS. EVEN AFTER I ADDED A LIMITED SLIP ADDITIVE, THE PROBLEM IS STILL THERE. IT TENDS TO BE WORSE AFTER A COLD START, AND WHEN I AM GOI…

Read full complaint

THE REAR DIFFERENTIAL IS MAKING A CHATTERING NOISE AT LOW SPEEDS. IT HAS A POSI-TRAC REAR DIFFERENTIAL, AND I CAN FEEL A 'STOP AND GO' TYPE ACTION AS I AM DRIVING IN A STRAIGHT LINE AT LOW SPEEDS. EVEN AFTER I ADDED A LIMITED SLIP ADDITIVE, THE PROBLEM IS STILL THERE. IT TENDS TO BE WORSE AFTER A COLD START, AND WHEN I AM GOING UP HILLS OF AFTER I GO OVER A SPEED BUMP. *TT

NHTSA ODI #10427965

28,000 miles · Sep 13, 2011
Power Train

(SUMMER, 2007, 28K) AT HIGHWAY SPEED (60 MPH) HUGE GRINDING NOISE AND VIBRATION, LIGHT IN DASH CAME ON BY ITSELF SHOWING, "4X4" TURNED ON, SLOWED TO 20 MPH, HUGE CLUNK AS 4 WHEEL DRIVE SYSTEM ENGAGED WITHOUT DRIVERS REQUESTING IT TO ENGAGE. FORD ROADSIDE ASSISTANCE WAS CONTACTED AND FORD TOWED VEHICLE TO FORD DEALER, FORD DEALER…

Read full complaint

(SUMMER, 2007, 28K) AT HIGHWAY SPEED (60 MPH) HUGE GRINDING NOISE AND VIBRATION, LIGHT IN DASH CAME ON BY ITSELF SHOWING, "4X4" TURNED ON, SLOWED TO 20 MPH, HUGE CLUNK AS 4 WHEEL DRIVE SYSTEM ENGAGED WITHOUT DRIVERS REQUESTING IT TO ENGAGE. FORD ROADSIDE ASSISTANCE WAS CONTACTED AND FORD TOWED VEHICLE TO FORD DEALER, FORD DEALER "REPROGRAMMED" SOMETHING, SAID IT HAD MOISTURE IN A SENSOR, CAUSING THE 4X4 TO TRY TO ENGAGE. (SEPTEMBER 12, 2011, 69,980 MILES) AT HIGHWAY SPEED, (58 MPH) DURING MILD ACCELERATION, 1500 - 1800 RPM, A MILD GRINDING SOUND FROM UNDER FRONT END, BY TAKING FOOT OFF GAS PEDDLE THEN REAPPLYING GAS THE GRINDING SOUND STOPS. CONTACTED FORD DEALER, THEY SAID DRIVE IT IN, CONTACTED FORD CUSTOMER SATISFACTION DEPARTMENT, THEY SAID TO HAVE DEALER CHECK IT OUT, FORD DEALER INVESTIGATED AND SAID THERE IS A PROBLEM WITH VOLUME OF VACUUM THAT IS NECESSARY TO PREVENT THE 4X4 SYSTEM FROM ENGAGING WHILE DRIVING ON THE HIGHWAY AT HIGHWAY SPEEDS. FORD DEALER INDICATED THAT IT MAYBE UNSAFE TO DRIVE LIKE THIS AND THAT THIS IS NORMAL FOR THE VACUUM SYSTEM TO FAIL LIKE THIS, REPRESENTATIVE AT FORD CUSTOMER SATISFACTION DEPARTMENT SAID THAT THEIR DEALER KNOWS HOW TO DIAGNOSE AND CURE PROBLEMS BEST, AND SINCE THE VEHICLE HAS MORE THAN 36K IT IS NOT A CONCERN TO FORD. MY CONCERN IS THAT STEEL GEARS THAT ARE SUGGESTED TO BE ENGAGED AT A WALKING PACE ON SOFT PAVEMENT ARE AUTOMATICALLY FORCING THEMSELVES TO LOCK TOGETHER ON DRY PAVEMENT AT 60 MPH, AND FORD AND THE FORD DEALER SHOW LITTLE CONCERN FOR THIS CONDITION SINCE THE VEHICLE HAS MORE THAN 36K AND SINCE NO EXTENDED WARRANTY PURCHASED FROM THE DEALERSHIP. *TR

NHTSA ODI #10425280

Mileage unknown · Sep 13, 2011
Power TrainService Brakes, Hydraulic

THE 2004 F150 AND I ASSUME EXPEDITIONS HAD UNDERSIZED FRONT BRAKE ROTORS AND CALIPERS AND WERE OUTLINED IN A SERVICE TECH BULLETIN FOR THE PURPOSE OF DIAGNOSING THE FRONT END SHAKING/SHIMMING DURING BRAKING. *TR THIS IS MY OPINION SHOULD HAVE FALLEN UNDER A MANDATORY RECALL DUE TO THE SERIOUS NATURE OF POOR ENGINEERING. NO RE…

Read full complaint

THE 2004 F150 AND I ASSUME EXPEDITIONS HAD UNDERSIZED FRONT BRAKE ROTORS AND CALIPERS AND WERE OUTLINED IN A SERVICE TECH BULLETIN FOR THE PURPOSE OF DIAGNOSING THE FRONT END SHAKING/SHIMMING DURING BRAKING. *TR THIS IS MY OPINION SHOULD HAVE FALLEN UNDER A MANDATORY RECALL DUE TO THE SERIOUS NATURE OF POOR ENGINEERING. NO RECALL AND OUT OF POCKET $$$. THE SAME HOLDS TRUE FOR THE REAR DIFFERENTIAL WHICH IN MY CASE HAS BEEN REPLACED (3) TIMES AND AGAIN FORD PUBLISHED A TECH BULLETIN OUTLINING THE FACT THAT THE '04 REAR DIFFERENTIAL HOUSING WAS SUBJECT TO FAULTY MACHINING CAUSING RAPID WEAR ON RING/PINION AND BEARINGS. I BELIEVE THESE TWO DEFECTS SHOULD HAVE BEEN ADDRESSED DUE TO THE FACT THAT FAILURE OF EITHER COMPONENT COULD RESULT IN A SERIOUS ACCIDENTS. I TRULY BELIEVE FORD TRIED TO COVER UP/WHITE WASH THESE DEFECTS. I STILL HAVE THIS '04 AND STILL HAVE ISSUES WITH THE BRAKES AND REAR DIFFERENTIAL NOT TO MENTION A HOST OF OTHER ISSUES THAT HAVE PLAGUED THIS PARTICULAR YEAR MODEL. I LOOK FORWARD TO HEARING FROM SOMEONE AND WOULD LIKE TO KNOW THE EXTENT OF FORDS INVOLVEMENT AND ANY ACCIDENTS INVOLVING '04F150'S. BEST REGADRS

NHTSA ODI #10425233

70,000 miles · Jul 15, 2011
Power Train

STARTED TO NOTICE SHAKING WHEN TURNING TO RIGHT, THEN LEFT AND AS SOON AS I STARTED TO MOVE FORWARD. THIS IS THE THIRD TIME I HAVE HAD THIS FAILURE AND EACH TIME THE DEALER HAS REPLACED THE REAR END CUTCHES AND ALL BEARINGS IN THE REAR END HOUSING. THE LAST TIME IT TOTALED OVER $900.00 AND 17,000 MILES AFTER IT IS HAPPENING AGAI…

Read full complaint

STARTED TO NOTICE SHAKING WHEN TURNING TO RIGHT, THEN LEFT AND AS SOON AS I STARTED TO MOVE FORWARD. THIS IS THE THIRD TIME I HAVE HAD THIS FAILURE AND EACH TIME THE DEALER HAS REPLACED THE REAR END CUTCHES AND ALL BEARINGS IN THE REAR END HOUSING. THE LAST TIME IT TOTALED OVER $900.00 AND 17,000 MILES AFTER IT IS HAPPENING AGAIN. THIS IS APPARANTY A COMMON PROBLEM SINCE THE DEALERS STOCK AL REQUIRED PARTS AND ARE NOT UNAWARE OF THIS FAIURE. I HAVE HAD THIS SAME FAIURE HAPPEN 3 TIMES IN 70,000 MILES AND THE MORE PEOPLE I TALK TO THE MORE I FIND THAT MOST HAVE HAD AT LEAST 1 FAIURE. FORD NEEDS TO STEP UP AND CORRECT A PROBLEM THAT EXISTS YET TODAY IN 2011 MODELS. *TT

NHTSA ODI #10413083

Official recalls

5

11V385000 · Fuel System, Gasoline:storage:tank Assembly:mounting

Jul 29, 2011

FORD IS RECALLING CERTAIN 1997 THROUGH 2003 MODEL YEAR FORD F-150, 2004 MODEL YEAR FORD F-150 HERITAGE, 1997 THROUGH 1999 MODEL YEAR F-250 LESS THAN 8,500 LBS. GROSS VEHICLE WEIGHT RATING (GVWR), AND 2002 AND 2003 LINCOLN BLACKWOOD VEHICLES MANUFACTURED FROM JUNE 20, 1995, THROUGH AUGUST 4, 2004, ORIGINALLY SOLD, OR CURRENTLY REGISTERED IN, CONNECTICUT, DELAWARE, ILLINOIS, INDIANA, IOWA, KENTUCKY, MAINE, MARYLAND, MASSACHUSETTS, MICHIGAN, MINNESOTA, MISSOURI, NEW HAMPSHIRE, NEW JERSEY, NEW YORK, OHIO, PENNSYLVANIA, RHODE ISLAND, VERMONT, WEST VIRGINIA, WISCONSIN, AND THE DISTRICT OF COLUMBIA. PROLONGED EXPOSURE TO ROAD DEICING CHEMICALS MAY CAUSE SEVERE CORROSION OF THE FUEL TANK STRAPS WHICH SECURE THE TANK TO THE VEHICLE.

Consequence & remedy

Consequence: AS A RESULT OF THE CORROSION, ONE OR BOTH STRAPS MAY FAIL ALLOWING THE FUEL LINES TO SEPARATE FROM THE TANK, OR IN SOME CASES, CAUSING THE TANK TO CONTACT THE GROUND. EITHER SCENARIO MAY RESULT IN A FUEL LEAK PRESENTING A FIRE HAZARD.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN DEALER TO HAVE THE FUEL TANK STRAPS REPLACED WITH STRAPS THAT HAVE INCREASED CORROSION PROTECTION. EARLY IN THIS CAMPAIGN, IF REPLACEMENT STRAPS ARE NOT AVAILABLE, DEALERS MAY INSTALL A CABLE SUPPORT UNDER THE STRAP AS AN INTERIM REPAIR OR A STEEL REINFORCEMENT OVER THE EXISTING STRAP AS A PERMANENT REPAIR. ANY REPAIRS WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON SEPTEMBER 16, 2011. OWNERS MAY CONTACT FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332. FORD'S RECALL CAMPAIGN NUMBER IS 11S21

11V107000 · Air Bags:frontal:driver Side:inflator Module

Feb 23, 2011

FORD IS RECALLING CERTAIN MODEL YEAR 2004-2006 F-150 PICK UP TRUCKS AS WELL AS CERTAIN MODEL YEAR 2006 LINCOLN MARK LT VEHICLES. IF THE CLOCKSPRING JUMPER WIRE COMES IN CONTACT WITH THE DRIVER SIDE FRONTAL AIR BAG LOWER HORN PLATE, THE WIRE INSULATION MAY BECOME CHAFED, CREATING A POTENTIAL FOR A SHORT CIRCUIT. IF THIS OCCURS THE AIR BAG WARNING LAMP MAY ILLUMINATE INDICATING THAT SERVICE IS REQUIRED.

Consequence & remedy

Consequence: THE DRIVER SIDE FRONTAL AIR BAG COULD INADVERTENTLY DEPLOY INCREASING THE RISK OF INJURY OR LOSS OF VEHICLE CONTROL IF OCCURRING WHILE IN MOTION.

Remedy: FORD WILL NOTIFY OWNERS AND INSTRUCT THEM TO TAKE THEIR VEHICLES TO A FORD OR LINCOLN/MERCURY DEALER TO HAVE A NEW CLOCKSPRING JUMPER WIRE INSTALLED THAT INCORPORATES A PROTECTIVE MESH COVER. REPAIRS WILL BE PERFORMED FREE OF CHARGE. THIS SAFETY RECALL BEGAN ON SOME VEHICLES IN MARCH 2011. THE RECALL CAMPAIGN ON THE EXPANDED POPULATION IS EXPECTED TO BEGIN ON OR ABOUT MAY 9, 2011. OWNERS MAY CONTACT THE FORD MOTOR COMPANY CUSTOMER RELATIONSHIP CENTER AT 1-866-436-7332.

07V336000 · Vehicle Speed Control

Aug 3, 2007

ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence & remedy

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON AS REPAIR PARTS ARE AVAILABLE (EXPECTED OCTOBER 2007), OWNERS WILL BE INSTRUCTED TO RETURN TO THE DEALERS FOR INSTALLATION OF A FUSED WIRING HARNESS. THE RECALL BEGAN ON AUGUST 13, 2007, AND MAILING COMPLETED BY SEPTEMBER 19, 2007. OWNERS MAY CONTACT FORD AT 1-888-222-2751.

04V443000 · Fuel System, Gasoline:storage:tank Assembly:mounting

Sep 13, 2004

ON CERTAIN TRUCKS EQUIPPED WITH 4.2L, 4.6L AND 5.4L GASOLINE ENGINES, THE FUEL TANK MAY HAVE A DEPRESSION AT THE SEAM BETWEEN THE TOP AND BOTTOM HALVES OF THE TANK. IF A DEPRESSION IS LARGE ENOUGH, FUEL MAY PERMEATE THE FUEL TANK WALL RESULTING IN A FUEL ODOR, ILLUMINATION, OF THE "SERVICE ENGINE SOON" INDICATOR LIGHT, OR A FUEL LEAK.

Consequence & remedy

Consequence: FUEL LEAKAGE, IN THE PRESENCE OF AN IGNITION SOURCE, COULD RESULT IN A FIRE.

Remedy: DEALERS WILL REPLACE THE FUEL TANK. THE RECALL BEGAN SEPTEMBER 17, 2004. OWNERS SHOULD CONTACT FORD AT 1-800-392-3673.

04V200000 · Fuel System, Gasoline:storage:tank Assembly

Apr 26, 2004

CERTAIN PICKUP TRUCKS MAY HAVE A FUEL TANK WITH LOCALIZED DEPRESSIONS IN THE FUEL TANK WALL AT THE SEAM BETWEEN TOP AND BOTTOM HALVES OF THE TANK. IF A DEPRESSION IS LARGE ENOUGH, FUEL MAY PERMEATE THE FUEL TANK WALL RESULTING IN A FUEL ODOR, OR THE "SERVICE ENGINE SOON" INDICATOR LIGHT IN THE INSTRUMENT CLUSTER MAY ILLUMINATE.

Consequence & remedy

Consequence: IF LEFT UNCORRECTED, A FUEL LEAK COULD EVENTUALLY DEVELOP.

Remedy: DEALERS WILL REPLACE THE FUEL TANK ON THESE VEHICLES. OWNER NOTIFICATION BEGAN ON MAY 6, 2004. OWNERS SHOULD CONTACT FORD AT 1-800-248-0186.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

4

EA11006 · Fuel Tank Strap Failure Due To Corrosion

Opened May 4, 2011 · Closed Aug 19, 2011

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly; Fuel System, Gasoline:storage:tank Assembly:mounting; Fuel System, Other:storage:tank Assembly; Fuel System, Other:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Additional source detail variants (4)

Fuel System, Gasoline:storage:tank Assembly

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Gasoline:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Other:storage:tank Assembly

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

Fuel System, Other:storage:tank Assembly:mounting

One or both of the steel straps holding up the fuel tank and attaching it to the truck frame can corrode and fail (break or separate).If one strap fails, the tank may tilt and drop and possibly contact the road surface.If both straps break, the entire tank may drop to the road.If either failure occurs while the vehicle is being driven, contact with the road can abrade the tank and create a hole from which gasoline can spill.When the tank drops, it remains attached to the vehicle only by the fuel filler hose and/or supply lines, or in rare instances, by the skid plate, if present.In some cases the weight of the tank sufficiently strained the hoses and fittings and caused separation and subsequent fuel leaks from those connections.The fire hazard created by leaking gasoline is increased by the possible presence of sparks created by the metal tank being dragged along the road.Corrosion of the straps appears to be caused by prolonged exposure to road deicers, frequently road salt, used to treat snow or ice covered roads.States in which large quantities of deicers are applied to roads during the winter season (salt belt states) account for the predominant portion of strap failures.Vehicles in these salt belt states are prone to experience corrosion related failures more frequently and earlier in a vehicle?s life cycle.Ford reports approximately 97 percent of reports it received relating to strap failure involve vehicles that were operated in these high corrosion areas, and 95 percent of the reports to NHTSA involved such vehicles.Approximately one-third of F-150 U.S. production was sold in salt belt states.ODI has included in the above counts reports it has received from consumers and reports it has received from Ford in which either the complaint involved confirmed strap corrosion or ODI's assessment of available information suggests corrosion caused the reported problem.Among the incidents reported to NHTSA, 441 involved one or both straps failing due to corrosion, 353 involved the fuel tank dropping and/or dragging on the ground, and 180 involved fuel leakage.ODI has received four reports of strap failure in which the leaking fuel ignited but self-extinguished, and one incident in which fire destroyed the vehicle and injured its driver.Ford reported the same injury incident and three other unique fire incidents, including two in which the leaking fuel ignited and fire destroyed the vehicle.There were no injuries associated with the three unique Ford incidents.Ford has agreed to conduct a recall to repair the subject vehicles.The recall will cover vehicles that were originally sold or are currently registered in salt belt states (regardless of vehicle age).The vehiclesincluded in the recall are those subject vehicles that are, or have ever been, registered in Connecticut, Delaware, Iowa, Illinois, Indiana, Kentucky, Maine, Maryland, Massachusetts, Michigan, Minnesota, Missouri, New Hampshire, New Jersey, New York, Ohio, Pennsylvania, Rhode Island, Vermont, West Virginia, Wisconsin, or the District of Columbia.Ford's recall action appears to adequately address the problem at this time.The above vehicle population (1,340,349) includes subject vehicles originally delivered or sold in salt belt states.ODI does not know the current or historical locations of all subject vehicles.According to Ford approximately 73% of the recall population is currently registered (a 27% attrition rate).Ford is also recalling certain MY 1997-1999 F-250 vehicles (under 8,500 GVWR), and MY2002-2003 Lincoln Blackwood vehicles for the same condition, resulting in an estimated 1.1 million total vehicles

EA10001 · Inadvertent Airbag Deployment

Opened Jan 13, 2010 · Closed Apr 25, 2011

Status: closed (inferred from source dates) · Air Bags; Air Bags:frontal; Air Bags:frontal:driver Side:inflator Module; Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Additional source detail variants (4)

Air Bags

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:driver Side:inflator Module

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

Air Bags:frontal:sensor/control MODULE-INACTIVE

ODI opened this investigation based on reports of inadvertent airbag deployment.Data provided by Ford indicated that the airbag clockspring jumper wire, which is situated inside the steering wheel assembly, was installed in a manner that would allow it to rub (abrade) against a sharp metal edge on the nearby horn plate.Because the horn plate is electrically grounded the abrasion of an airbag wire on the sharp edge could cause a short circuit condition.As a result the airbag light may illuminate and/or the airbag may inadvertently deploy.Inadvertent deployments are most likely to occur during the airbag system's self-diagnostic test that initiates when the ignition switch is turned on.Ford modified the vehicle design in late January 2006 adding a protective tape over the sharp metal edge of the horn plate.Ford made additional design changes on MY 2007 vehicles to the horn plate, the clockspring jumper, and the connector layouts to further address this issue.ODI identified 318 deployment incidents with 121 alleged injury reports from subject vehicles.All but one of the incident and injury reports occurred in vehicles built before the January 2006 modification.In addition, there was one incident and alleged injury reported in the MY 2006 Mark LT vehicles that share the same design. In letters dated February 21 and April 11, 2011, Ford announced a recall of all of the approximately 1.3 million MY 2004-2006 F-150 vehicles built prior to January 24, 2006, the date the initial vehicle modification was made.In addition, approximately 14,000 MY 2006 Mark LT vehicles built prior to January 24, 2006 will also be recalled.Vehicles built after that date, which contain the modification, are not within the recall scope.Accordingly the investigation is closed.

PE08063 · Cng Regulator Leak

Opened Oct 31, 2008 · Closed Feb 27, 2009

Status: closed (inferred from source dates) · Fuel System, Other; Fuel System, Other:delivery; Fuel System, Other:delivery:hoses, Lines/piping, And Fittings; Fuel System, Other:fuel Injection System

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Additional source detail variants (4)

Fuel System, Other:delivery

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other:delivery:hoses, Lines/piping, And Fittings

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

Fuel System, Other:fuel Injection System

THE AGENCY HAS CLOSED THIS INVESTIGATION BASED ON ITS REVIEW OF COMPLAINT REPORTS, DISCUSSIONS WITH COMPLAINANTS AND FIELD AND TECHNICAL DATA PROVIDED BY FORD.THE SUBJECT VEHICLES ARE 1/2 TON PICKUP TRUCKS AND ARE NATURAL GAS VEHICLES (NGV) THAT ARE FUELED BY GASOLINE OR COMPRESSED NATURAL GAS.THE AGENCY HAS RECEIVED REPORTS ALLEGING IMPROPER OPERATION OF THE NATURAL GAS FUEL PRESSURE REGULATOR ALLOWING RELEASE OF EXCESS AMOUNTS OF NATURAL GAS INTO THE ENGINE COMPARTMENT.FORD REPORTS THAT THE REGULATOR CONTAINS AN OVER PRESSURE RELIEF VALVE THAT WILL VENT NATURAL GAS SHOULD THE PRESSURE EXCEED A SET THRESHOLD.THE COMPLAINT REPORTS AND DATA REVIEWED BY THE AGENCY INDICATE THAT AN IMPROPERLY OPERATING PRESSURE REGULATOR CAN RESULT IN AN OVERPRESSURE CONDITION AND ACTIVATE THE REGULATOR PRESSURE RELIEF VALVE.THE RELEASED NATURAL GAS IS DIRECTED THROUGH A VENT HOSE THAT DISCHARGES THE NATURAL GAS IN THE VICINITY OF THE RIGHT FRONT WHEEL HOUSE AND AWAY FROM THE ENGINE COMPARTMENT'S EXTREMELY HOT AREAS/SURFACES.OWNERS ARE NORMALLY AWARE OF THIS PROBLEM BY THE PRESENCE OF AN ILLUMINATED WARNING LIGHT INSIDE THE VEHICLE, ODOR OF NATURAL GAS OR THE SOUND OF VENTING GAS.WHEN THE OPERATOR TURNS THE ENGINE OFF, THE NATURAL GAS SUPPLY TANK SOLENOID WILL CLOSE AND THE REGULATOR WILL NOT RELEASE NATURAL GAS.AT VEHICLE RESTART, THE SOLENOID VALVE WILL REMAIN CLOSED TO PREVENT LEAKAGE AND THE VEHICLE WILL ONLY OPERATE IN THE GASOLINE MODE.A SAFETY-RELATED DEFECT HAS NOT BEEN IDENTIFIED AT THIS TIME AND FURTHER USE OF AGENCY RESOURCES DOES NOT APPEAR TO BE WARRANTED.ACCORDINGLY, THIS INVESTIGATION IS CLOSED.THE CLOSING OF THIS INVESTIGATION DOES NOT CONSTITUTE A FINDING BY NHTSA THAT A SAFETY-RELATED DEFECT DOES NOT EXIST.THE AGENCY WILL MONITOR THIS ISSUE AND RESERVES THE RIGHT TO TAKE FURTHER ACTION IF WARRANTED BY THE CIRCUMSTANCES.

DP05005 · Spark Plug Ejection From Cylinder Head

Opened Sep 22, 2005 · Closed Jan 4, 2006

Status: closed (inferred from source dates) · Engine And Engine Cooling; Engine And Engine Cooling:engine; Engine And Engine Cooling:engine:gasoline

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Additional source detail variants (3)

Engine And Engine Cooling:engine

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Engine And Engine Cooling:engine:gasoline

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.

Engine And Engine Cooling

ON SEPTEMBER 6, 2005, ODI RECEIVED A PETITION REQUESTING THAT THE AGENCY INVESTIGATE ALLEGATIONS OF ENGINE SPARK PLUG EJECTION IN CERTAIN MODEL YEAR 1997 THROUGH 2004 FORD VEHICLES WITH TRITON V-8 AND V-10 ENGINES.ODI RECEIVED A TOTAL OF 474 NON-DUPLICATIVE COMPLAINTS ON THE SUBJECT VEHICLES WHERE THE COMPLAINANT, OR THE DEALER REPAIRING THE VEHICLE, REPORTED THAT A SPARK PLUG DETACHED FROM THE CYLINDER AND/OR EJECTED FROM THE ENGINE.AS OF DECEMBER 8, 2005, ODI IS NOT AWARE OF ANY ALLEGATIONS WHERE THE ALLEGED DEFECT RESULTED IN A LOSS OF VEHICLE CONTROL, A CRASH, AN INJURY, OR A FATALITY IN ANY OF THE 10,319,810 SUBJECT VEHICLES.IN ADDITION, ODI IS AWARE OF ONLY TWO INCIDENTS WHERE THE VEHICLE STALLED WITHOUT RESTART.INFORMATION CONTAINED IN THE ODI CONSUMER COMPLAINTS AND OBTAINED FROM 72 TELEPHONE INTERVIEWS WITH COMPLAINANTS SHOWED THE FOLLOWING:(1) 99% OF THE COMPLAINTS WERE ON MY 1997 TO 2002 SUBJECT VEHICLES.(2) MOST THE COMPLAINANTS REPORTED HEARING A LOUD POP WHILE DRIVING OR UPON STARTING UP THE VEHICLE FOLLOWED BY A LOUD, REPETITIVE CLICKING OR POPPING SOUND.(3) MANY OF THE COMPLAINANTS REPORTED THAT THE POPPING SOUND WAS ACCOMPANIED BY SOME LOSS OF VEHICLE POWER; HOWEVER, IN 99% OF THE INCIDENTS REPORTED, THE VEHICLE DID NOT STALL.IN THE VERY FEW INCIDENTS WHERE THE VEHICLE DID STALL, MOST VEHICLES COULD BE RESTARTED.(4) ONLY A SMALL PERCENTAGE OF THE COMPLAINANTS CITED THAT THEY SMELLED GAS OR A SLIGHT BURNING SMELL WHEN THE INCIDENT OCCURRED.(5) IN ALL BUT A VERY FEW INCIDENTS, VEHICLE DAMAGE WAS LIMITED TO THE ENGINE.IN ONE INCIDENT, THE COMPLAINT REPORTED THAT THE FUEL RAIL WAS DAMAGED AND REPLACED AFTER ONE OF THE SPARK PLUGS EJECTED FROM THE ENGINE; HOWEVER, THE COMPLAINANT REPORTED THAT THE DAMAGE DID NOT RESULT IN ANY TYPE OF FUEL LEAK OR FIRE.IN ANOTHER INCIDENT, THE ONLY INCIDENT WHERE A FIRE WAS ALLEGED, THE COMPLAINANT REPORTED THAT NO FLUID LEAK WAS OBSERVED, BUT THAT A FIRE RESULTED AFTER THE SPARK PLUG HAD EJECTED FROM THE ENGINE AND HE HAD RESTARTED THE VEHICLE AND DRIVEN TO ANOTHER LOCATION.NONE OF THE COMPLAINANTS REPORTED ANY DAMAGE TO THE VEHICLE HOOD.(6) ONLY TWO COMPLAINANTS REPORTED THAT THEY OBSERVED WHAT APPEARED TO BE SOME DROPS OF FUEL COMING FROM THE CYLINDER WHERE THE SPARK PLUG HAD FAILED OR ON THE SPARK PLUG ITSELF; HOWEVER, EACH OF THESE COMPLAINANTS REPORTED THAT THERE WAS NO SMOKE OR FLAMES AS A RESULT OF HIS INCIDENT.AS THE PETITIONER NOTED, AND ODI?S ANALYSIS SHOWED, IT IS POSSIBLE FOR A SPARK PLUG TO DETACH FROM THE ENGINE CYLINDER THREADS IN THE SUBJECT VEHICLES.HOWEVER, ODI?S ANALYSIS OF 474 COMPLAINTS DESCRIBING SUCH INCIDENTS FOUND ONLY A VERY FEW ALLEGED ANY SAFETY-RELATED CONSEQUENCES.NONE OF THESE SHOWED ANY EVIDENCE OF A SERIOUS SAFETY CONSEQUENCE.GIVEN THE LARGE POPULATION AND RELATIVELY LONG EXPOSURE TIME OF THE SUBJECT VEHICLES, THE COMPLAINT ANALYSIS INDICATES THAT THE RISK TO MOTOR VEHICLE SAFETY FROM THE ALLEGED DEFECT IS VERY LOW.IN VIEW OF THE FOREGOING, IT IS UNLIKELY THAT NHTSA WOULD ISSUE AN ORDER FOR THE NOTIFICATION AND REMEDY OF THE ALLEGED DEFECT AT THE CONCLUSION OF THE INVESTIGATION REQUESTED IN THE PETITION.THEREFORE, IN VIEW OF THE NEED TO ALLOCATE AND PRIORITIZE NHTSA?S LIMITED RESOURCES TO BEST ACCOMPLISH THE AGENCY?S SAFETY MISSION, THE PETITION IS DENIED.