← New search

1992 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1992 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 49 of 470 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 231 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 48 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Engine And Engine Cooling. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

20 crash reports38 fire reports11 injury reports

What owners actually said

470 reports
Mileage unknown · Jul 15, 1997
Power Train

CONSUMER HAS HAD TO REPLACE SIX BUSHINGS WITHIN THE LAST 10 DAYS. THE PLASTIC BUSHINGS THAT HOLD THE CLUTCH ROD WHEN APPLIED PRESSURE IS ON THE BUSHINGS, WILL BRAKE, LEAVING THE VEHICLE UNMANAGEABLE BY THE DRIVER. *AK

NHTSA ODI #814235

Mileage unknown · Jul 8, 1997
Electrical SystemFire

WHEN CONSUMER WENT TO START VEHICLE SMOKE CAME OUT OF THE IGNITION SWITCH. THE VEHICLE DID START A FEW MOMENTS AFTERWARDS. THE VEHICLE HAS NOT BEEN SEEN BY DEALER OR MECHANIC.

NHTSA ODI #813897

Mileage unknown · Jun 23, 1997
Service Brakes, Hydraulic

THE ABS LOCKS UP WHEN IN RAIN/SNOW/CAR WASH. DEALER CAN'T DO ANYTHING ABOUT IT. *AK

NHTSA ODI #813398

Mileage unknown · Jun 2, 1997
Fuel System, Gasoline

OWNER STATES THAT FRONT FUEL CELLS LEAK, HAS NOT TAKEN VEHICLE TO DEALER OWNER IS CONCERNED OF POSSIBLE FIRE HAZARD. *AK *JB

NHTSA ODI #812669

Mileage unknown · Jun 2, 1997
Fuel System, Gasoline

RECEIVED RECALL NOTICE FROM DEALER, TOOK VEHICLE TO DEALER AND THEY SAID THAT THEY HAD CORRECTED THE RECALL. WHEN CONSUMER TOOK VEHICLE OFF THE LOT AND STARTED DRIVING THE FUEL PUMP RIGHT BACK TO THE BACK OF THE TANK ASSEMBLY. RECALL 93 V125 000. CONSUMER STATES THAT RECALL WAS NEVER DONE BECAUSE THE VEHICLE IS STILL DOING THE …

Read full complaint

RECEIVED RECALL NOTICE FROM DEALER, TOOK VEHICLE TO DEALER AND THEY SAID THAT THEY HAD CORRECTED THE RECALL. WHEN CONSUMER TOOK VEHICLE OFF THE LOT AND STARTED DRIVING THE FUEL PUMP RIGHT BACK TO THE BACK OF THE TANK ASSEMBLY. RECALL 93 V125 000. CONSUMER STATES THAT RECALL WAS NEVER DONE BECAUSE THE VEHICLE IS STILL DOING THE SAME THING. *AK

NHTSA ODI #812629

Mileage unknown · May 21, 1997
Engine And Engine Cooling

DRIVER HEARD WHAT APPEARED AN EXHUAST LEAK, BOTH MANIFOLDS CRACKED IN THE SAME IDENTICAL PLACE DURING NORMAL OPERATING CONDITIONS DUE TO DETERIORATION. *AK

NHTSA ODI #812435

Mileage unknown · May 9, 1997
Service Brakes, Hydraulic

EVERY SIX MONTHS PADS AND CALIPERS NEED TO BE REPLACED. HAVE BEEN REPLACED 5 TIMES IN 2 YEARS, CAUSE UNKNOWN. *AK

NHTSA ODI #811026

Mileage unknown · Apr 23, 1997
Fuel System, Gasoline

WHEN SELECTING THE FUEL SELECTOR TO REAR TANK, FUEL STILL SPILLS OUT OF FRONT TANK. DEALER IS AWARE OF PROBLEM. OWNER IS NOT ABLE TO REPAIR AT THIS TIME. *AK

NHTSA ODI #811579

Mileage unknown · Apr 14, 1997
Fuel System, Gasoline

CONSUMER HAS NOTICED THAT THE INTAKE MANIFOLD HAS TWO CRACKS ON BOTH SIDES WHICH IS CAUSING EXHAUST FUMES TO ENTER THE VEHICLE. *AK

NHTSA ODI #810930

Mileage unknown · Apr 9, 1997
Fuel System, Gasoline

FUEL INJECTOR PUMP DEFECTIVE.

NHTSA ODI #516312

Official recalls

3

94V169001 · Parking Brake:conventional

Sep 7, 1994

THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.

Consequence & remedy

Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.

Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

92V006000 · Structure:body:door

Jan 14, 1992

WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.

Consequence & remedy

Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.

Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

8

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93020 · Parking Brake Failure

Opened Jul 28, 1993 · Closed Sep 23, 1994

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

Additional source detail variants (2)

Service Brakes, Hydraulic

There is no summary currently available

Service Brakes, Hydraulic

There is no summary currently available

PE93015 · Parking Brake Failure

Opened Mar 9, 1993 · Closed Jul 27, 1993

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available