FIRESTONE PATHFINDER ATR 31X15 TIRE FAILURE AT APPROX 70-75MPH. TREAD CAME OFF THE TIRE AND WRAPPED AROUND THE AXEL, INSD HAS THE TIRE. (CLAIM# 23-1257-097) *MW
1992 Ford F-150
Owner reports · Recalls · Investigations
Similar to other model years
Owner complaints for the 1992 Ford F-150 do not stand out strongly from the model-year median of 676.
About this comparison →How this year compares
Owner complaints by model year
Compare all F-150 years →Counts vary with age, sales and reporting. They are not failure rates.
What owners reported most
All reported categories
Tap a category to read its complaints. One report may name several components.
When problems were reported
Mileage at the reported incident
Limited mileage data: 49 of 470 reports include usable mileage. There isn’t enough coverage to show a useful chart.
NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.
What to inspect
Issues worth paying extra attention to based on owner reports.
- Fuel System, Gasoline. Review the 231 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Electrical System. Review the 48 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
- Engine And Engine Cooling. Review the 37 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
NHTSA owner reports · September 18, 2026 snapshot.
What owners actually said
470 reportsCONSUMER WAS EXPERIENCING THE SAME PROBLEM AS STATED IN RECALL 93V125000.*AK A MALFUNCTIONING VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSED FUEL SPILLAGE. *YH
MY TIRES FAILED A DIFFERENT WAY .THE RUBBER SEPARATED FROM THE BEAD THAT SEALS AGAINST THE WHEEL. I HAVEN' T HEARD OF THIS PROBLEM BEING MENTION DURING THIS RECALL. I HAD TO HAVE TWO FIRESTONE ATX TIRES REPLACED WITHIN THE LAST TWO YEARS. BOTH TIRES WERE REPLACED WITH THE SAME PROBLEM. THE PROBLEM I ENCURED IS AS DANGEROUS …
Read full complaint
MY TIRES FAILED A DIFFERENT WAY .THE RUBBER SEPARATED FROM THE BEAD THAT SEALS AGAINST THE WHEEL. I HAVEN' T HEARD OF THIS PROBLEM BEING MENTION DURING THIS RECALL. I HAD TO HAVE TWO FIRESTONE ATX TIRES REPLACED WITHIN THE LAST TWO YEARS. BOTH TIRES WERE REPLACED WITH THE SAME PROBLEM. THE PROBLEM I ENCURED IS AS DANGEROUS AS THE TREAD SEPARATION THAT YOU ARE INVESTIGATING.( DOT NUMBER: TIRE SIZE: 235/75/R15 )
THE TRUCK DEVELOPED A SLIGHT VIBRATION THAT FELT LIKE IT WAS IN THE FRONT END. IT WAS. THE TIRE WAS STARTING TO SEPERATE. FIRESTONE WAS CONTACTED AND THEY SAID THEY WOULD HAVE TO LOOK AT THE TIRE. TO CONDENSE THE STORY, FIRESTONE SAID THEY COULD NOT MAKE AN ADJUSTMENT TO THE TIRE BECAUSE IT WAS OVER FIVE YEARS OLD. NOTE: THE …
Read full complaint
THE TRUCK DEVELOPED A SLIGHT VIBRATION THAT FELT LIKE IT WAS IN THE FRONT END. IT WAS. THE TIRE WAS STARTING TO SEPERATE. FIRESTONE WAS CONTACTED AND THEY SAID THEY WOULD HAVE TO LOOK AT THE TIRE. TO CONDENSE THE STORY, FIRESTONE SAID THEY COULD NOT MAKE AN ADJUSTMENT TO THE TIRE BECAUSE IT WAS OVER FIVE YEARS OLD. NOTE: THE TIRE(S) HAVE GOOD TREAD AND WERE NOT ABUSED. ALSO, THE TIRES ARE SITTING IN THE GARAGE (FOR MONTHS)STILL MOUNTED AND THAT ONE TIRE IS SELF-DESTRUCTING ON ITS OWN. THE TIRE IS NO LONGER TRUE (ROUND), LOOSING ITS TREAD AND EVEN THE BELT PLYS APPEAR TO BE PULLING APART. THE TIRE: FIRESTONE FIREHAWK ATX 31*10.5R15LT M/S LOAD RANGE B.( DOT NUMBER: VD60AXP235 TIRE SIZE: 31*10.5R15 )
TIME OF INCIDENT 07:30 AM; NO HEAVY LOAD; ENTIRE TREAD CAME OFF SEVERLY DAMAGING LEFT SIDE PANEL, PIPE TO GAS TANK, AND BED. TRUCK WAS YANKED AROUND, BUT GAINED CONTROL. TIRE CONTINUED TO HOLD AIR, AND WAS STILL HOLDING AIR UNTIL NEW TIRE WAS PURCHASED. I PURCHASED A COMPLETE NEW SET OF WILDERNESS TIRES ON THE SAME DAY DUE T…
Read full complaint
TIME OF INCIDENT 07:30 AM; NO HEAVY LOAD; ENTIRE TREAD CAME OFF SEVERLY DAMAGING LEFT SIDE PANEL, PIPE TO GAS TANK, AND BED. TRUCK WAS YANKED AROUND, BUT GAINED CONTROL. TIRE CONTINUED TO HOLD AIR, AND WAS STILL HOLDING AIR UNTIL NEW TIRE WAS PURCHASED. I PURCHASED A COMPLETE NEW SET OF WILDERNESS TIRES ON THE SAME DAY DUE TO MILEAGE AND NOT WANTING MISMATCHED TIRES. NOW I AM STUCK WITH ANOTHER SET THAT COULD POTENTIALLY BE JUST AS DANGEROUS. THIS INCIDENT OCCURED PRIOR TO THE PUBLICITY ON FIRESTONE TIRES. OTHERWISE, I WOULD HAVE BOUGHT ANOTHER BRAND. I HAD NEVER HAD PROBLEMS WITH FIRESTONE TIRES BEFORE, AND THOUGHT THE PROBLEM I HAD WAS DUE TO MILEAGE OR JUST A SINGLE DEFECTIVE TIRE.( DOT NUMBER: VD60AXB506 TIRE SIZE: 31105R15 )
WHEN BOTH FUEL TANKS ARE FULL, PRESSURE BUILDS UP AND FORCES FUEL TO SPEW OUT OF ONE OF THE GAS CAPS. I HAVE HAD A COUPLD OF MOTORISTS FLAG ME DOWN TO TELL THIS AND THEN WHEN I STOP IT CONTINUES TO SPURT OUT FOR A FEW MINUTES. WHEN BOTH TANKS ARE LESS THAN FULL, THE FUEL WILL RETURN TO THE EMPTIER TANK EVERY TIME UNTIL BOTH TANK…
Read full complaint
WHEN BOTH FUEL TANKS ARE FULL, PRESSURE BUILDS UP AND FORCES FUEL TO SPEW OUT OF ONE OF THE GAS CAPS. I HAVE HAD A COUPLD OF MOTORISTS FLAG ME DOWN TO TELL THIS AND THEN WHEN I STOP IT CONTINUES TO SPURT OUT FOR A FEW MINUTES. WHEN BOTH TANKS ARE LESS THAN FULL, THE FUEL WILL RETURN TO THE EMPTIER TANK EVERY TIME UNTIL BOTH TANKS BALANCE THE AMOUNT OF FUEL. THIS ALSO CAUSES THE PRESSURE BUILD UP AND FUEL TO SPURT OUT OF THE GAS CAP. THIS PROBLEM HAD BEEN HANDLED ON A RECALL NOTICE BY THE PRIOR OWNER OF MY TRUCK SO I AM TOLD BY FORD THAT THEIR OBLIGATION IS DONE. MY OPINION IS THAT MY VEHICLE IS STILL A SAFETY THREAT FROM FORDS PARTS (EVEN A SECOND SET OF PARTS AFTER THE RECALL). FORD INSISTS THEY WILL NOT PAY FOR THIS. I AM HAVING MY MECHANIC FIX THIS FOR ME AT A PRICE OF NEARLY $800 SO I FEEL SAFE TO DRIVE MY TRUCK THAT FORD WONT TAKE RESPONSIBILITY FOR.
I DID NOT KNOW THIS WAS A PROBLEM WITH THOUSANDS OF FORDS UNTIL THE NEWS REPORTS. THIS HAS ALWAYS BEEN A SAFETY ISSUE FOR US.
FUEL PUMP CHECK VAULVE DOES NOT PREVENT FUEL FROM GOING FROM ONE TANK TO THE OTHER CAUSING TANKS TO OVER FILL. WHICH IS A BIG FIRE AND ENVIROMENTAL PROBLEM. THEY DID PUT IN A NEW CHECK VALUE BUT IT WENT OUT TOO THEY NEED TO REPLACE THE BAD VALVES
IGNITION SWITCH FAILURE DUE TO BROKEN SHIFT TUBE AND DAMAGE TO ASSOCIATE PARTS. DEALER NOTIFIED, AND MADE REPAIRS AT CONSUMER'S COST. PLEASE PROVIDE FURTHER DETAILS. *AK
WHILE DRIVING HAD TREAD SEPARATION ON FIVE DIFFERENTS TIMES. FIRESTONE, ATX, P235/75R15. *AK
Official recalls
394V169001 · Parking Brake:conventional
Sep 7, 1994
THE PARKING BRAKE CONTROL SELF-ADJUST PAWL DOES NOT LINE UP PROPERLY WITH THE SELF-ADJUST RACHET CAUSING THE PAWL TO SLIP OVER ONE OR MORE TEETH IN THE RACHET.
Consequence & remedy
Consequence: WHEN THE ABOVE OCCURS, IT CAN RESULT IN PARKING BRAKE SYSTEM INEFFECTIVENESS. THE PARKING BRAKE WILL NOT HOLD THE VEHICLE, CAUSING THE VEHICLE TO ROLL FREELY, IF THE TRANSMISSION IS NOT LEFT IN GEAR.
Remedy: A WEDGE WILL BE INSTALLED WHICH WILL SERVE TO LOCK THE PARKING BRAKE SELF-ADJUST MECHANISM PAWL INTO ENGAGEMENT WITH THE RACHET. ALSO, OWNERS WILL BE ADVISED TO RELEASE AND REAPPLY THE PARKING BRAKE WHENEVER TOOTH SKIP OCCURS AND WILL BE REMINDED TO ALWAYS TURN OFF THE ENGINE AND LEAVE THE VEHICLE IN GEAR WHEN THE VEHICLE IS PARKED.
93V125000 · Fuel System, Gasoline:storage:tank Assembly
Aug 2, 1993
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence & remedy
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
92V006000 · Structure:body:door
Jan 14, 1992
WATER CAN ENTER THE DOOR LATCH RELEASE CABLE. IF THE VEHICLE IS OPERATED IN BELOW FREEZING TEMPERATURES, THE WATER IN THE DOOR LATCH RELEASE CABLE CAN FREEZE AND CAUSE THE LATCH MECHANISM TO MALFUNCTION.
Consequence & remedy
Consequence: THE MALFUNCTION OF THE DOOR LATCH RELEASE CAN RESULT INTHREE DIFFERENT PROBLEMS: 1) THE DOOR WILL NOT BE ABLE TO BE RELATCHED, 2) THEINSIDE DOOR HANDLE CAN BECOME INOPERATIVE, AND 3) THE DOOR COULD APPEAR TO BELATCHED WHEN IT IS NOT, ALLOWING THE DOOR TO OPEN UNEXPECTEDLY IF IT IS JARRED,AND INCREASING THE RISK OF INJURY TO THE ADJACENT SEAT OCCUPANT.
Remedy: REVISED DOOR RELEASE CABLES AND WATER SHIELDS WILL BE INSTALLED.
Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗
NHTSA investigations
8EA99032 · Dual Fuel Tank Crossflow/leakage
Opened Nov 4, 1999 · Closed Dec 6, 2001
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Additional source detail variants (2)
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
Vehicle Speed Control:linkages
ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.
RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage
Opened May 29, 1998 · Closed Nov 4, 1999
Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly
THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.
EA93022 · Idle Air Spd Ctrl Vlv Malf
Opened Jul 30, 1993 · Closed Aug 31, 1994
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93020 · Parking Brake Failure
Opened Jul 28, 1993 · Closed Sep 23, 1994
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
Additional source detail variants (2)
Service Brakes, Hydraulic
There is no summary currently available
Service Brakes, Hydraulic
There is no summary currently available
PE93015 · Parking Brake Failure
Opened Mar 9, 1993 · Closed Jul 27, 1993
Status: closed (inferred from source dates) · Service Brakes, Hydraulic
There is no summary currently available
PE93010 · Idle Air Spd Ctrl Vlv Malf
Opened Mar 2, 1993 · Closed Jul 30, 1993
Status: closed (inferred from source dates) · Engine And Engine Cooling
There is no summary currently available
EA93001 · Fuel Expulsion
Opened Jan 7, 1993 · Closed Aug 20, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
PE92077 · Fuel Expulsion
Opened Sep 9, 1992 · Closed Jan 7, 1993
Status: closed (inferred from source dates) · Vehicle Speed Control:linkages
There is no summary currently available
Illustration