← New search

1991 Ford F-150

Owner reports · Recalls · Investigations

Similar to other model years

Owner complaints for the 1991 Ford F-150 do not stand out strongly from the model-year median of 676.

About this comparison →

When problems were reported

Mileage at the reported incident

Limited mileage data: 39 of 304 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 149 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Electrical System. Review the 50 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →
  • Service Brakes, Hydraulic. Review the 23 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

12 crash reports41 fire reports7 injury reports

Electrical System complaints

50 reports
Clear category filter
Mileage unknown · Apr 10, 2001
Electrical SystemFire

VEHICLE CAUGHT ON FIRE, AND BURNED HOOD, WIRE HARNESS AND ALTERNATOR, ETC.*AK

NHTSA ODI #885600

Mileage unknown · Oct 10, 2000
Electrical System

KEY GOT STUCK IN THE ON POSTION. BATTERY CABLE HAD TO BE DISCONNECTED IN ORDER TO TURN VEHICLE OFF. DEALER JUST STATED THERE WERE NOT RECALLS. CONSUMER WILL CONTACT MANUFACTURER TO REGISTER A COMPLAINT.*AK

NHTSA ODI #872572

Mileage unknown · Oct 9, 2000
Electrical System

THE TFI MODULE FAILED, I REPLACED IT WITH AN OEM PART, I WANT REIMBURSEMENT, KNOWN DEFECT

NHTSA ODI #733760

Mileage unknown · Jul 24, 2000
Electrical SystemFire

VEHICLE HAS CAUGHT ON FIRE FOR THE 6TH TIME. EACH TIME IT HAS BEEN DIAGNOSED TO BE THE UNDER DASH OR FRONT HOOD. DEALER HAS NEVER GIVEN A REASON FOR THE PROBLEM. *AK

NHTSA ODI #865879

Mileage unknown · Mar 22, 2000
Electrical System

IN AUGUST-SEPTEMBER 1997 I RESPONDED TO NHTSA RECALL 96V071000. THE DEALER IN PUYALLUP, WA REPLACED THE IGNITION SWITCH. HOWEVER, EVERY SINCE THEN WHEN THE TEMPERATURE DROPS DOWN BELOW 40 DEGREES THE IGNITION SWITCH SEEMS TO FREEZE UP. THIS ONLY HAPPENS IN THE FALL OR WINTER. I AM UNABLE TO TURN THE IGNITION SWITCH TO START …

Read full complaint

IN AUGUST-SEPTEMBER 1997 I RESPONDED TO NHTSA RECALL 96V071000. THE DEALER IN PUYALLUP, WA REPLACED THE IGNITION SWITCH. HOWEVER, EVERY SINCE THEN WHEN THE TEMPERATURE DROPS DOWN BELOW 40 DEGREES THE IGNITION SWITCH SEEMS TO FREEZE UP. THIS ONLY HAPPENS IN THE FALL OR WINTER. I AM UNABLE TO TURN THE IGNITION SWITCH TO START THE TRUCK. THE SWITCH BECOMES VERY STIFF UNLESS I FIRST WARM THE STEERING COLUMN WITH A SPACE HEATER OR BLOW DRYER. I AM AFRAID THAT ONE OF THESE DAYS I WILL BREAK THE SWITCH WHILE ATTEMPTING TO START THE TRUCK. *AK

NHTSA ODI #720454

Mileage unknown · Mar 13, 2000
Electrical SystemVehicle Speed Control

WHEN USING THE SPEED CONTROL, AND HAVING TO ACTIVATE THE LEFT TURN SIGNAL TO PASS, SPEED CONTROL CUTS OUT, CAUSING THE TRUCK TO SEVERELY DECELERATE. *AK

NHTSA ODI #858386

Mileage unknown · Oct 29, 1999
Electrical SystemFire

VEHICLE FIRE DUE TO POSSIBLE RECALL COMPONENT FAILURE (IGNITION SWITCH-96V-071) RESULTING IN VEHICLE FIRE. MJS

NHTSA ODI #549432

Mileage unknown · Feb 17, 1999
Electrical SystemEngine And Engine CoolingFuel System, Gasoline

ENGINE HESITATES TO ACCELERATE WHEN COLD.

NHTSA ODI #530562

Mileage unknown · Nov 9, 1998
Electrical SystemFire

THE CONSUMER EXPERIENCED PROBLEMS WITH ALTERNATOR. WHILE THEY WERE DRIVING, THEY STARTED SMELLING SMOKE. IN ADDITION, STARTED NOTICING SMOKE COMING FROM THE HOOD. WHEN THEY PULLED OVER AND LIFTED THE HOOD THEY NOTICED THAT THE ALTERNATOR WAS ON FIRE. THE FIRE DEPARTMENT CAME AFTER THE FIRE DIED OUT ON ITS OWN. THE MANUFACTU…

Read full complaint

THE CONSUMER EXPERIENCED PROBLEMS WITH ALTERNATOR. WHILE THEY WERE DRIVING, THEY STARTED SMELLING SMOKE. IN ADDITION, STARTED NOTICING SMOKE COMING FROM THE HOOD. WHEN THEY PULLED OVER AND LIFTED THE HOOD THEY NOTICED THAT THE ALTERNATOR WAS ON FIRE. THE FIRE DEPARTMENT CAME AFTER THE FIRE DIED OUT ON ITS OWN. THE MANUFACTURER HAS BEEN CONTACTED.*AK

NHTSA ODI #830472

Mileage unknown · Oct 31, 1997
Electrical SystemFire

THE VEHICLE GOT ON FIRE WHILE WAS PARKED. CONSUMER SAID "THE FIRE STARTED ON THE IGNITION SWITCH, AND ALSO ACCORDING TO THE DEALER. *AK

NHTSA ODI #818105

Official recalls

3

96V071000 · Electrical System:ignition

Apr 25, 1996

THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence & remedy

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

93V125000 · Fuel System, Gasoline:storage:tank Assembly

Aug 2, 1993

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence & remedy

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

93V066000 · Steering: Steering Wheel/handle Bar

Apr 27, 1993

KEYS ATTACHED TO THE KEY RING OF AN IGNITION KEY WHILE IT IS IN THE VEHICLE IGNITION CAN BECOME LODGED IN THE STEERING LOCK RECEIVER AS THE STEERING WHEEL IS BEING TURNED.

Consequence & remedy

Consequence: THE LODGED KEYS CAN CAUSE LOSS OF STEERING CONTROL, WHICHCAN RESULT IN AN ACCIDENT WHEN THE VEHICLE IS BEING USED ON THE HIGHWAY.

Remedy: A SHIELD WILL BE POSITIONED BETWEEN THE STEERING WHEEL AND THE IGNITION SWITCH AND HELD IN PLACE BY THE STEERING LOCK BAND.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

12

EA99032 · Dual Fuel Tank Crossflow/leakage

Opened Nov 4, 1999 · Closed Dec 6, 2001

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Additional source detail variants (2)

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

Vehicle Speed Control:linkages

ON JULY 14, 1993 FORD FILED A DEFECT INFORMATION REPORT CONCERNING FUEL TANK CROSS FLOW LEAKAGE ON F-SERIES LIGHT TRUCKS AND CAB CHASSIS BUILT FROM JULY 22, 1989 THROUGH DECEMBER 17, 1992.THE REMEDY WAS TO REPLACE THE FUEL PRESSURE REGULATOR AND INSTALL A CHECK VALVE BETWEEN EACH FUEL SUPPLY LINE AND FUEL TANK (2) TO REPAIR THE SUPPLY SIDE FUEL CROSS FLOW PROBLEM (RECALL 93V-125).ODI OPENED RQ98-008 ON MAY 29, 1998 BECAUSE OF THE LARGE NUMBER OF ALLEGED REMEDY FAILURES AND REPORTS OF FUEL CROSS FLOW ON VEHICLES OUTSIDE OF THE RECALL POPULATION.BASED ONTHE INFORMATION RECEIVED FROM FORD ON AUGUST 11, SEPTEMBER 30, AND DECEMBER 15, 1998, AND THE INCREASING TREND OF REMEDY FAILURES AND OUT OF SCOPE CROSSFLOW REPORTS, ODI OPENED EA99-032 ON NOVEMBER 4, 1999.THE ATTACHED ENGINEERING ANALYSIS CLOSING REPORT FULLY DESCRIBES THE RESULTS OF THIS INVESTIGATION AND REASON FOR CLOSING.THE SUBJECT VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO MALFUNCTIONS IN THE FUEL SYSTEM.WHEN FUEL IS PUMPED OR RETURNED TO THE NON-OPERATING TANK (CROSS FLOW), THE CAPACITY OF THE NON-OPERATING TANK CAN BE EXCEEDED, CAUSING FUEL TO OVERFLOW PAST THE FILLER CAP, CREATING A FIRE POTENTIAL.

RQ98008 · Ford F-SERIES Dual Fuel Tank Leakage

Opened May 29, 1998 · Closed Nov 4, 1999

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

THESE VEHICLES CAN EXPERIENCE FUEL TRANSFER FROM ONE TANK TO THE OTHER DUE TO A MALFUNCTIONING FUEL PUMP.FROM THE INFORMATION GATHERED TO DATE, IT APPEARS THAT THERE CAN BE MULTIPLE CAUSES AND/OR A COMBINATION OF CAUSES FOR FUEL CROSS FLOW AND THAT THE RECALL REMEDY MAY BE INADEQUATE.FURTHER INVESTIGATION IS NEEDED.THIS INVESTIGATION IS UPGRADED TO EA99-032.CLICK ON DOCUMENT SEARCH BUTTON FOR ADDITIONAL INFORMATION.

EA93022 · Idle Air Spd Ctrl Vlv Malf

Opened Jul 30, 1993 · Closed Aug 31, 1994

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

PE93010 · Idle Air Spd Ctrl Vlv Malf

Opened Mar 2, 1993 · Closed Jul 30, 1993

Status: closed (inferred from source dates) · Engine And Engine Cooling

There is no summary currently available

EA93001 · Fuel Expulsion

Opened Jan 7, 1993 · Closed Aug 20, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE92077 · Fuel Expulsion

Opened Sep 9, 1992 · Closed Jan 7, 1993

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

EA92029 · Front Seat Back Failure

Opened Aug 27, 1992 · Closed Oct 29, 1993

Status: closed (inferred from source dates) · Seats

There is no summary currently available

PE92042 · Fnt Reclning Seat Bck Fail

Opened Apr 17, 1992 · Closed Aug 27, 1992

Status: closed (inferred from source dates) · Seats:front Assembly:recliner

There is no summary currently available

EA91044 · Loss Of Brake Effectivenes

Opened Oct 30, 1991 · Closed Oct 30, 1992

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

===

EA91031 · Fuel Expulsion

Opened Jun 26, 1991 · Closed Nov 1, 1991

Status: closed (inferred from source dates) · Vehicle Speed Control:linkages

There is no summary currently available

PE91077 · Loss Of Brake Effectivenes

Opened May 23, 1991 · Closed Oct 31, 1991

Status: closed (inferred from source dates) · Service Brakes, Hydraulic

There is no summary currently available

PE91064 · Transmission Fluid Fires

Opened Apr 9, 1991 · Closed Jul 5, 1991

Status: closed (inferred from source dates) · Power Train