← New search

2006 Ducati Monster S4 R

Owner reports · Recalls · Investigations

Limited comparison data

There is not enough comparable history to draw a useful model-year comparison.

About this comparison →

How this year compares

Owner complaints by model year

Other model years Selected year
Compare all Monster S4 R years →

Counts vary with age, sales and reporting. They are not failure rates.

What owners reported most

Tap a category to read its complaints. One report may name several components.

When problems were reported

Mileage at the reported incident

Limited mileage data: 12 of 12 reports include usable mileage. There isn’t enough coverage to show a useful chart.

NHTSA’s mileage field refers to the reported incident, not necessarily the filing date. This shows report counts, not the likelihood of a failure.

What to inspect

Issues worth paying extra attention to based on owner reports.

  • Fuel System, Gasoline. Review the 12 owner reports in this category and discuss these concerns during a pre-purchase inspection. Read reports →

NHTSA owner reports · September 18, 2026 snapshot.

0 crash reports0 fire reports0 injury reports

Fuel System, Gasoline complaints

12 reports
Clear category filter
11,556 miles · Mar 18, 2011
Fuel System, Gasoline

2006 DUCATI MONSTER S2R GAS TANK IS EXPANDING AND FLEXING. EVENTUAL FAILURE WOULD LEAD TO FUEL LEAKING ONTO HOT ENGINE AND EXHAUST PARTS. *TR

NHTSA ODI #10390565

7,127 miles · Feb 28, 2011
Fuel System, Gasoline

MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IG…

Read full complaint

MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRAME. I HAVE NOT SIGNIFICANTLY MODIFIED MY MOTORCYCLE EXCEPT FOR AN AFTERMARKET EXHAUST AND SOME COSMETIC CHANGES. I HAVE MADE NO MODIFICATIONS TO THE FUEL TANK OR FUEL PUMP. I TOOK THE BIKE TO THE DEALER (HATTAR MOTORSPORTS) WHO SUBMITTED A CLAIM TO DUCATI NORTH AMERICA (THE IMPORTER/FACTORY). I HAVE BEEN TOLD IT WILL BE REPLACED. I AM VERY CONCERNED AS TO THE SAFETY OF THIS MOTORCYCLE NOW. THE TANK'S SWELLING HAS MADE IT SO THE HANDLEBARS DO NOT TURN CORRECTLY. IF THE TANK SWELLS ENOUGH, IT WILL SPLIT OPEN AND I AM CONCERNED THIS WILL HAPPEN WHILE I AM RIDING. *TR

NHTSA ODI #10384801

12,000 miles · Jan 13, 2011
Fuel System, Gasoline

PLASTIC FUEL TANK SWELLING. *TR

NHTSA ODI #10376612

6,100 miles · Dec 5, 2010
Fuel System, Gasoline

I OWN A 2006 DUCATI MONSTER S2R-1000 (PURCHASED NEW 11/2006), AND IT HAS A PLASTIC GAS TANK THAT HAS BECOME DISTORTED FROM ITS ORIGINAL SHAPE. MY FUEL TANK HAS BECOME DISTORTED ON THE LEFT/ RIGHT SIDES OF THE TANK IN THE AREA WHERE MY KNEES TOUCH THE TANK. THERE IS SOME TYPE OF DEMFORMATION AROUND THE GAS CAP, WHICH…

Read full complaint

I OWN A 2006 DUCATI MONSTER S2R-1000 (PURCHASED NEW 11/2006), AND IT HAS A PLASTIC GAS TANK THAT HAS BECOME DISTORTED FROM ITS ORIGINAL SHAPE. MY FUEL TANK HAS BECOME DISTORTED ON THE LEFT/ RIGHT SIDES OF THE TANK IN THE AREA WHERE MY KNEES TOUCH THE TANK. THERE IS SOME TYPE OF DEMFORMATION AROUND THE GAS CAP, WHICH IS CAUSING THE PAINT TO CRACK. THE RUBBER PUCKS, WHICH ARE ON THE BOTTOM OF THE TANK, SUPPORT THE TANK ON THE FRAME. THE PUCKS NO LONGER SIT CORRECTLY ON THE FRAME, AND THE TANK DOES NOT SIT SECURELY ON THE FRAME. *TR

NHTSA ODI #10369241

950 miles · Sep 25, 2010
Fuel System, Gasoline

I HAVE A 2006 DUCATI MONSTER S2R1000 WITH APPROXIMATELY 2500 MILES ON IT. MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIO…

Read full complaint

I HAVE A 2006 DUCATI MONSTER S2R1000 WITH APPROXIMATELY 2500 MILES ON IT. MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS HIT IT ON TURNING, AND IT PRESSES AGAINST THE IGNITION SWITCH. PREVIOUSLY IT OPENED AND CLOSED WITHOUT PROBLEMS, NOW I HAVE TO WEDGE IT AGAINST THE IGNITION SWITCH TO CLOSE IT. THE RUBBER MOUNTS NO LONGER SIT ON THE FRAME. I HAVE MADE NO MODIFICATIONS TO THE FUEL TANK OR FUEL PUMP. THE BIKE IS COMPLETELY STOCK. I AM VERY CONCERNED AS TO THE SAFETY OF THIS MOTORCYCLE NOW. THE TANK'S SWELLING HAS MADE IT SO THE HANDLEBARS DO NOT TURN CORRECTLY. IF THE TANK SWELLS ENOUGH, IT WILL SPLIT OPEN AND I AM CONCERNED THIS WILL HAPPEN WHILE I AM RIDING. AS WELL I FEAR THIS MAY BE A FIRE HAZARD AS GAS COULD SPILL OUT WHILE RIDING. I ASKED THE LOCAL DUCATI DEALER ABOUT THE PROBLEM AND THEY INFORMED ME THAT THE ONLY WAY THAT THEY COULD REPLACE OR LOOK AT IS IF HAS ALREADY STARTED TO LEAK FUEL, WHICH MINE HAS NOT YET. *TR

NHTSA ODI #10357644

5,000 miles · Jun 23, 2010
Fuel System, Gasoline

PLASTIC GAS TANK EXPANDING ON DUCATI MONSTER S2R1000. TANK HAS NOT RUPTURED OR FAILED YET, BUT CONTINUED EXPANSION COULD CAUSE DAMAGE. *TR

NHTSA ODI #10339666

12,000 miles · Jun 20, 2010
Fuel System, Gasoline

THE PLASTIC GAS TANK ON MY MOTORCYCLE IS SWELLING, CAUSING IT TO NOT FIT PROPERLY ON THE FRAME ANYMORE. IT IS ALSO INTERFERING WITH THE IGNITION SWITCH AND TANK LATCH MECHANISM. THERE IS ALSO COSMETIC DAMAGE (RIPPLES) ON THE SIDE OF THE TANK. AM WORRIED THAT TANK WILL EVENTUALLY FAIL OR LEAK. *TR

NHTSA ODI #10339198

3,400 miles · Jun 19, 2010
Fuel System, Gasoline

THE GAS TANK ON MY 2006 DUCATI MONSTER S2R HAS EXPANDED IN BOTH WIDTH AND LENGTH. THE LARGER DIMENSIONS NOW ALLOW THE HANDLEBARS TO HIT THE TANK WHICH COULD CAUSE A LOSS OF CONTROL/CRASH. ANOTHER WORRISOME ISSUE WITH AN EVER-EXPANDING PLASTIC GAS TANK IS THE FACT THAT IT SITS IN YOUR LAP WHILE RIDING. NOT REALLY WHERE I WOULD WA…

Read full complaint

THE GAS TANK ON MY 2006 DUCATI MONSTER S2R HAS EXPANDED IN BOTH WIDTH AND LENGTH. THE LARGER DIMENSIONS NOW ALLOW THE HANDLEBARS TO HIT THE TANK WHICH COULD CAUSE A LOSS OF CONTROL/CRASH. ANOTHER WORRISOME ISSUE WITH AN EVER-EXPANDING PLASTIC GAS TANK IS THE FACT THAT IT SITS IN YOUR LAP WHILE RIDING. NOT REALLY WHERE I WOULD WANT A SUDDEN EXPULSION OF FLAMMABLE LIQUID ONTO A HOT ENGINE WHEN THE TANK SPLITS OPEN. *TR

NHTSA ODI #10339126

9,500 miles · Dec 4, 2009
Fuel System, Gasoline

MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS NEARLY HIT IT ON TURNING, AND IT NEARLY PRESSES AGAINST THE IGNITION SWITCH. THE RUBBER MOUNTS NO LONGER SIT ON THE FRAME - THEY EACH SIT OUT 1/4 TO 1/2"…

Read full complaint

MY MOTORCYCLE HAS A PLASTIC GAS TANK WHICH HAS BEGUN TO EXPAND. THE OUTSIDE DIMENSIONS OF THE TANK HAVE INCREASED AND IT NOW DOES NOT SIT CORRECTLY IN THE FRAME, THE HANDLEBARS NEARLY HIT IT ON TURNING, AND IT NEARLY PRESSES AGAINST THE IGNITION SWITCH. THE RUBBER MOUNTS NO LONGER SIT ON THE FRAME - THEY EACH SIT OUT 1/4 TO 1/2". I HAVE NOT SIGNIFICANTLY MODIFIED MY MOTORCYCLE EXCEPT FOR AN AFTERMARKET EXHAUST AND SOME COSMETIC CHANGES. I HAVE MADE NO MODIFICATIONS TO THE FUEL TANK OR FUEL PUMP. I TOOK THE BIKE TO THE DEALER WHO ADJUSTED THE TANK AND THOUGHT IT WAS SIMPLY OUT OF ADJUSTMENT. I AM VERY CONCERNED AS TO THE SAFETY OF THIS MOTORCYCLE NOW. THE TANK'S SWELLING HAS MADE IT SO THE HANDLEBARS DO NOT TURN CORRECTLY. IF THE TANK SWELLS ENOUGH, IT WILL SPLIT OPEN AND I AM CONCERNED THIS WILL HAPPEN WHILE I AM RIDING. *TR

NHTSA ODI #10294562

8,000 miles · Nov 10, 2009
Fuel System, Gasoline

RECENTLY FOUND THAT MY FUEL TANK ON MY 2006 DUCATI MONSTER S2R 800 MOTORCYCLE HAS EXPANDED AND IS BECOMING DEFORMED CAUSING CONTACT BETWEEN LATCH AND IGNITION SWITCH. ALSO FOUND THAT THE TANK NO LONGER PROPERLY RESTS ON THE FRAME. *TR

NHTSA ODI #10291789

Official recalls

0

No recalls in this snapshot.

Model-level recall history does not show whether a particular VIN is affected or has received a repair. Check a VIN with NHTSA ↗

NHTSA investigations

1

PE10045 · Fuel Leak At Pump/tank Interface

Opened Nov 4, 2010 · Closed Feb 28, 2011

Status: closed (inferred from source dates) · Fuel System, Gasoline:storage:tank Assembly

After opening this PE, we met with subject owners, dealers, and Ducati North America personnel.We learned that the subject leakage is limited to the Multistrada line alone and is unrelated to composite fuel tank deformation.Rather it stems from the inability of the original sealing O-ring to conform to the tank's relatively rough sealing surface.Recall 11V-020 provides a new X section O-ring to address the Multistrada issue and with that recall, this PE is closed for the Multistrada.Meanwhile, unlike the Multistrada, the Monster line fails to exhibit a current safety defect trend and, on that basis, this PE is closed for those models as well.